ANSI ASTM F555-2001 Standard Test Method for Motor Life Evaluation of an Upright Vacuum Cleaner《立式真空吸尘器电动机寿命评定试验方法》.pdf
《ANSI ASTM F555-2001 Standard Test Method for Motor Life Evaluation of an Upright Vacuum Cleaner《立式真空吸尘器电动机寿命评定试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F555-2001 Standard Test Method for Motor Life Evaluation of an Upright Vacuum Cleaner《立式真空吸尘器电动机寿命评定试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F555 01 (Reapproved 2016) An American National StandardStandard Test Method forMotor Life Evaluation of an Upright Vacuum Cleaner1This standard is issued under the fixed designation F555; the number immediately following the designation indicates the year of originaladoption or, in the
2、case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers motor life evaluation of house-hold or commercial single and dual mo
3、tor upright vacuumcleaners (uprights with separate motors for creating thevacuum and driving the floor brush). Self-propelled or power-assist cleaners are not within the scope of this test method.1.2 This test method is limited to evaluation of the uprightvacuum cleaner electric motor(s).1.3 This te
4、st method provides a test to determine operatinglife of the motor(s), before servicing is needed, by an acceler-ated laboratory procedure. Motor(s) are tested while mountedand operated in the upright vacuum cleaner.1.4 The values stated in inch-pound units are to be regardedas standard. The values g
5、iven in parentheses are mathematicalconversions to SI units, which are provided for informationonly and are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establ
6、ish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D75 Practice for Sampling AggregatesE337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-p
7、eratures)F431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum CleanersF608 Test Method for Evaluation of Carpet Embedded DirtRemoval Effectiveness of Household/CommercialVacuum CleanersF655 Specification for Test Carpets and Pads for VacuumCleaner Testing3. Terminology3.1 De
8、finitions of Terms Specific to This Standard:3.1.1 motor lifelimited by failure of motor. Failure ismotor stoppage. In the case of a dual motor upright, the testwill be continued until both motors (vacuum motor and floorbrush motor) have failed. The motor that fails first will bereplaced so that the
9、 test may continue on the other motor. Themotor life of each motor will be recorded separately.3.1.1.1 DiscussionAny failure integral with the motor,such as armature assembly, field assembly, housing(s),bearings, motor cooling fan or primary air moving fan, brushassemblies, motor mounted nonresettab
10、le thermal protectiondevices, or any other component judged to be integral with themotor, shall be judged as motor stoppage.4. Significance and Use4.1 The test results provide an indication of the motor life ofan electric upright vacuum cleaner. End of motor life will bejudged in accordance with Sec
11、tion 3.5. Apparatus and Materials5.1 Voltage Regulator System, to control the input voltage tothe vacuum cleaner. The regulator system shall be capable ofmaintaining the vacuum cleaners rated voltage 61 % andrated frequency 61 Hz, having a wave form that is essentiallysinusoidal with 3 % maximum har
12、monic distortion for theduration of the test.5.2 Voltmeter, to provide measurements accurate to within61%.5.3 Timer and Switch, having the capacity to control theoff/on duty cycle of the cleaner during the life test.5.4 Sharp Edge Orifice Platea114-in. (32-mm) diameterorifice shall be in accordance
13、with Fig. 2 of Specification F431.5.5 Wattmeter, to provide measurements accurate to within1%.5.6 Plenum Chamber, conforming to the plenum chamberdescribed in Specification F431.5.7 Water Manometer, or equivalent instrument measuringin increments of 0.1 in. (2.54 mm).1This test method is under the j
14、urisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.30 on Durability-Reliability.Current edition approved Oct. 1, 2016. Published October 2016. Originallyapproved in 1985. Last previous edition approved in 2011 as F555 01 (2011).DOI: 10.1520/F0555-
15、01R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO
16、 Box C700, West Conshohocken, PA 19428-2959. United States15.8 Barometer, to provide measurements accurate to 60.05in. Hg (1.27 mm Hg), with scale divisions 0.02 in. (0.51 mm)or finer.5.9 Thermometer, having a range of at least 18 to 80F (8to +27C) and graduated in 1F (0.5C) increments.5.10 Psychrom
17、eter, meeting the requirements of TestMethod E337 for thermometers, graduated in increments of1F (0.5C).5.11 Test Carpet, conforming to the level loop carpetdescribed in Specification F655.Acarpet that provides equiva-lent nozzle loading results may be used.5.12 Carpet Padding (optional), if used, t
18、he test carpetpadding will conform to the padding described in SpecificationF655.5.13 Test Fixture, a moving surface covered by the testcarpet supported on the test pad, which moves with a horizon-tal reciprocating motion, for a stroke distance of 27 in. (686mm) in each direction at the average rate
19、 of 1.8 ft/s (0.55 m/s),which results in 24 cycles (forward and back) per minute. Thismotion shall be generated by rotating a 13.5-in. (343-mm)radius arm, which shall be connected to the platform with anarm at least 24 in. (610 mm) long or equivalent. This deviceshall provide means to hold the clean
20、er fixed by its handlestationary in the operating position while it is in contact withthe reciprocating surface (see Fig. 1). Optionally, the cleanercan be moved through the same cycle as stated above while thecarpeted platform is held stationary (see Fig. 1). For eitheroption, the reciprocating mot
21、ion shall follow the same dutycycle as specified for the vacuum cleaner in 7.7. For theoptional test fixture of Fig. 1, the reciprocating arm must be ateither end of its horizontal motion at the start of each “on”portion of the cycle.5.14 Test Dirt, Wedron sand/talc mixture. See Annex A1.6. Sampling
22、6.1 Test a minimum of three units (or a larger sample size ifdesired) of similar models using the same motor style andamperage. Select all samples at random in accordance withgood statistical practice. Results shall provide an 80 % confi-dence level within 610 % of the mean value. If not, testadditi
23、onal samples or reduce the results by the penalty factor ascalculated in 7.10.7. Procedure For Motor Life Evaluation7.1 Determine initial performance as follows:7.1.1 Seal the nozzle opening to the plenum chamber with amanometer (or equivalent) connected to the chamber and witha114-in. (32-mm) diame
24、ter sharp-edge orifice in the holder.For the test, connect the agitator drive belt and a clean filter orfilter bag to the cleaner. The agitator shall be operating freelywith the handle in the operating position as shown in Fig. 1.7.1.2 With the cleaner sealed to the plenum chamber andwithout an orif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF5552001STANDARDTESTMETHODFORMOTORLIFEEVALUATIONOFANUPRIGHTVACUUMCLEANER 立式 真空 吸尘器 电动机 寿命 评定

链接地址:http://www.mydoc123.com/p-433268.html