ANSI ASTM F2018-2000 Standard Test Method for Time-to-Failure of Plastics Using Plane Strain Tensile Specimens《使用水平应力拉伸样品测定塑料失效时间的试验方法》.pdf
《ANSI ASTM F2018-2000 Standard Test Method for Time-to-Failure of Plastics Using Plane Strain Tensile Specimens《使用水平应力拉伸样品测定塑料失效时间的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F2018-2000 Standard Test Method for Time-to-Failure of Plastics Using Plane Strain Tensile Specimens《使用水平应力拉伸样品测定塑料失效时间的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2018 00 (Reapproved 2010)Standard Test Method forTime-to-Failure of Plastics Using Plane Strain TensileSpecimens1This standard is issued under the fixed designation F2018; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the requirements to determinethe time-to-failure of thermoplastic resins for pi
3、ping applica-tions by uniaxial loading of a grooved tensile test specimen.This grooved tensile specimen achieves a multi-axial stresscondition, which mimics the stress condition found in pressur-ized solid-wall plastic pipe. The ratio of the stress in the axialdirection to the transverse direction a
4、pproximates that for apressurized solid-wall pipe specimen.1.2 It is intended that the data generated on these specimensbe analyzed according to the methodology set forth in TestMethod D2837 to generate a long-term strength design valuefor the material.1.3 The values stated in SI units are to be reg
5、arded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter
6、mine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1598 Test Method for Time-to-Failure of Plastic PipeUnder Constant Internal PressureD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD2837 Test Method for Obtaining Hydrostatic Desig
7、n Basisfor Thermoplastic Pipe Materials or Pressure Design Basisfor Thermoplastic Pipe ProductsD2990 Test Methods for Tensile, Compressive, and FlexuralCreep and Creep-Rupture of PlasticsD1928 Practice for Preparation of Compression-MoldedPolyethylene Test Sheets and Test Specimens (Withdrawn2001)3D
8、4703 Practice for Compression Molding ThermoplasticMaterials into Test Specimens, Plaques, or SheetsF412 Terminology Relating to Plastic Piping Systems2.2 Other Document:PPI TR-4 HDB Listed Materials43. Terminology3.1 Definitions:3.1.1 Definitions are in accordance with Terminology F412,and abbrevia
9、tions are in accordance with Terminology D1600.3.1.2 long-term strength (LTS)the estimated tensile stressin the test specimen that when applied continuously will causefailure of the specimen at 100 000 h. This is the intercept of thestress regression line with the 100 000-h coordinate.4. Summary of
10、Test Method4.1 This test method consists of a description of the groovedtensile test specimen and its use in various environments toobtain the long-term strength capacity for piping materials.Such a controlled environment may be accomplished by, but isnot limited to, immersing the specimens in a con
11、trolled-temperature water bath or circulating-air oven.5. Significance and Use5.1 The data obtained by this test method are useful forestablishing stress versus failure-time relationships in a con-trolled environment. The long-term strength (LTS) is deter-mined primarily for materials used in moldin
12、g applications.The LTS categorized in accordance with Table 1 of ASTMD2837 is known as the SDB (strength design basis).NOTE 1These SDB values will be published in PPI TR-4 for materialsused in molding applications only.1This test method is under the jurisdiction of ASTM Committee F17 on PlasticPipin
13、g Systems and is the direct responsibility of Subcommittee F17.40 on TestMethods.Current edition approved Aug. 1, 2010. Published November 2010. Originallyapproved in 2000. Last previous edition approved in 2006 as F201800(2006). DOI:10.1520/F2018-00R10.2For referenced ASTM standards, visit the ASTM
14、 website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from Plastic
15、s Pipe Institute (PPI), 105 Decker Court, Suite 825,Irving, TX 75062, http:/www.plasticpipe.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 The test method can also be used on an experimentalbasis for pipe-grade materials as a
16、n indicator of stress-ruptureperformance. The long-term strength or SDB values obtainedby this test method are not intended to replace the HDBdetermined for pressure pipe tested in accordance with TestMethod D1598.5.3 In order to determine how plastics will perform in pipefitting applications, it is
17、 necessary to establish the stress-failuretime relationships over four or more decades of time (hours) ina controlled environment. Because of the nature of the test andspecimens employed, no single line can adequately representthe data, and therefore the confidence limits should be estab-lished.NOTE
18、 2Some materials may exhibit a nonlinear relationship betweenlog-stress and log-failure time, usually at short failure-times. In suchcases, the 105- hour stress value computed on the basis of short-term testdata may be significantly different than the value obtained when adistribution of data points
19、 in accordance with Test Method D2837 isevaluated. However, these data may still be useful for quality control orother applications, provided correlation with long-term data has beenestablished.6. Apparatus6.1 Constant-Temperature SystemA reservoir capable ofmaintaining a fluid bath at a uniform tem
20、perature shall be used.If water or other liquid medium is used, agitation is permittedto stabilize the temperature throughout the fluid bath. If an airor other gaseous environment is used, provision shall be madefor adequate circulation. The test may be conducted at 23C(73F) or other selected temper
21、atures as required and thetemperature tolerance requirements shall be 6 2C (6 3.6F).A typical test setup is shown in Fig. 1.6.2 Loading SystemAny device that is capable of continu-ously applying constant load on the specimen may be used.The device shall be capable of reaching the test load withoutex
22、ceeding it and of holding it within the tolerances shown in6.5 for the duration of the test. A typical loading system isshown in Fig. 2, which utilizes a pressurized cylinder to applyload to the specimen. Other creep load frames can be used,such as those described in Test Methods D2990 for tensilecr
23、eep. The loading system shall be checked with a load cell thathas a calibration certificate traceable to National Institute forStandards and Technology (NIST).6.3 Load or Pressure GageA load gage or, for use with anair cylinder, a pressure gage that meets the tolerance require-ments in 6.5 is requir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF20182000STANDARDTESTMETHODFORTIMETOFAILUREOFPLASTICSUSINGPLANESTRAINTENSILESPECIMENS 使用 水平 应力

链接地址:http://www.mydoc123.com/p-432993.html