BS ISO 11040-3-2012 Prefilled syringes Seals for dental local anaesthetic cartridges《预灌装注射器 牙科局部麻醉品玻璃管》.pdf
《BS ISO 11040-3-2012 Prefilled syringes Seals for dental local anaesthetic cartridges《预灌装注射器 牙科局部麻醉品玻璃管》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 11040-3-2012 Prefilled syringes Seals for dental local anaesthetic cartridges《预灌装注射器 牙科局部麻醉品玻璃管》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 11040-3:2012Prefilled syringesPart 3: Seals for dental local anaestheticcartridgesBS ISO 11040-3:2012 BRITISH STANDARDNational forewordThis British Standard is the UK impl
2、ementation of ISO 11040-3:2012.The UK participation in its preparation was entrusted to TechnicalCommittee CH/212, IVDs.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contr
3、act. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 70606 6ICS 11.040.10; 11.040.25; 11.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was publ
4、ished under the authority of theStandards Policy and Strategy Committee on 29 February 2012.Amendments issued since publicationDate Text affectedBS ISO 11040-3:2012 ISO 2012Prefilled syringes Part 3:Seals for dental local anaesthetic cartridgesSeringues prremplies Partie 3: Rondelles dtanchit pour c
5、artouches dentaires danesthsie localeINTERNATIONAL STANDARDISO11040-3Second edition 2012-01-15Reference number ISO 11040-3:2012(E)BS ISO 11040-3:2012ISO 11040-3:2012(E)ii ISO 2012 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2012All rights reserved. Unless otherwise specified, no part of this
6、 publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 G
7、eneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 11040-3:2012ISO 11040-3:2012(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work
8、 of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmen
9、tal, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main
10、 task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.Atten
11、tion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights.ISO 11040-3 was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and injection, and blood p
12、rocessing equipment for medical and pharmaceutical use.This second edition cancels and replaces the first edition (ISO 11040-3:1993), which has been technically revised.ISO 11040 consists of the following parts, under the general title Prefilled syringes: Part 1: Glass cylinders for dental local ana
13、esthetic cartridges Part 2: Plunger stoppers for dental local anaesthetic cartridges Part 3: Seals for dental local anaesthetic cartridges Part 4: Glass barrels for injectables and ready-to-use prefillable syringes Part 5: Plunger stoppers for injectables Part 6: Plastics barrels for injectablesThe
14、following parts are under preparation: Part 7: Packaging systems for prefillable ready-to-use syringes ISO 2012 All rights reserved iiiBS ISO 11040-3:2012ISO 11040-3:2012(E)IntroductionPrimary packaging components made of elastomeric materials are an integral part of medicinal products. Therefore, t
15、he principles of current good manufacturing practices (cGMP) apply to the manufacturing of these components.Principles of cGMP are described in ISO 15378 or in the GMP Guidelines published by the European Community and the United States of America.iv ISO 2012 All rights reservedBS ISO 11040-3:2012Pr
16、efilled syringes Part 3: Seals for dental local anaesthetic cartridges1 ScopeThis part of ISO 11040 specifies the shape, dimensions, material, performance requirements and labelling of seals for dental local anaesthetic cartridges intended for single use only.NOTE The potency, purity, stability and
17、safety of a medicinal product during its manufacture and storage can be significantly affected by the nature and performance of the primary packaging.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the editio
18、n cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 3302-1, Rubber Tolerances for products Part 1: Dimensional tolerancesISO 7619-1, Rubber, vulcanized or thermoplastic Determination of indentation hardness Part 1: Durometer m
19、ethod (Shore hardness)ISO 7885:2010, Dentistry Sterile dental injection needles for single useISO 8871-1, Elastomeric parts for parenterals and for devices for pharmaceutical use Part 1: Extractables in aqueous autoclavatesISO 8871-4, Elastomeric parts for parenterals and for devices for pharmaceuti
20、cal use Part 4: Biological requirements and test methodsISO 8871-5:2005, Elastomeric parts for parenterals and for devices for pharmaceutical use Part 5: Functional requirements and testingISO 8872, Aluminium caps for transfusion, infusion and injection bottles General requirements and test methodsI
21、SO 11040-1, Prefilled syringes Part 1: Glass cylinders for dental local anaesthetic cartridgesISO 11040-2, Prefilled syringes Part 2: Plunger stoppers for dental local anaesthetic cartridges3 ClassificationSeals shall be classified as follows: type A: seals with a mono-layer disc; type B: seals with
22、 a double-layer disc.4 Shape and dimensions4.1 The shape and dimensions of seals shall be as shown in Figure 1 and given in Table 1.INTERNATIONAL STANDARD ISO 11040-3:2012(E) ISO 2012 All rights reserved 1BS ISO 11040-3:2012ISO 11040-3:2012(E)Dimensions in millimetresType A: Seal with a mono-layer d
23、iscType B: Seal with a double-layer discShape and dimensions of seals for dental local anaesthetic cartridgesDimensions of sealsDimensions in millimetresNominal size Type Total cap heightaThickness of discInner cap diameterBore diameterh1h2d1d20,15 0,15 0,05 0,37,5 A 4,85 to 4,9 1,3 to 1,5 7,5 3,07,
24、5 B 4,85 to 5,3 1,45 to 1,95 7,5 3,0aThe height of the seal depends on the thickness and hardness of the disc.4.2 For type B seals, both single layers shall be continuous. The thickness ratio of the single layers shall be agreed upon between the supplier and user.4.3 The diameter of the rubber discs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1104032012PREFILLEDSYRINGESSEALSFORDENTALLOCALANAESTHETICCARTRIDGES 灌装 注射器 牙科 局部 麻醉品 玻璃管 PDF

链接地址:http://www.mydoc123.com/p-583449.html