ANSI ASTM D1494-2012 Standard Test Method for Diffuse Light Transmission Factor of Reinforced Plastics Panels《增强塑料板的散射光透射系数的标准试验方法》.pdf
《ANSI ASTM D1494-2012 Standard Test Method for Diffuse Light Transmission Factor of Reinforced Plastics Panels《增强塑料板的散射光透射系数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D1494-2012 Standard Test Method for Diffuse Light Transmission Factor of Reinforced Plastics Panels《增强塑料板的散射光透射系数的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1494 12 An American National StandardStandard Test Method forDiffuse Light Transmission Factor of Reinforced PlasticsPanels1This standard is issued under the fixed designation D1494; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test
3、method covers the determination of the diffuselight transmission factor of translucent reinforced plasticsbuilding panels.1.2 The values stated in SI units are to be regarded as thestandard. The values given in the parentheses are for informa-tion only.1.3 The text of this standard references notes
4、and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in Tables and Figures) shall not be consideredas requirements of this standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
5、of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no know ISO equivalent to this standard2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for Test
6、ingD883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ASTM Adjuncts:Test Cabinet for Diffuse Light Transmission Factor ofReinforced Panels33. Terminology3
7、.1 Definitions:GeneralDefinitions are in accordance withTerminology D883 and abbreviations with TerminologyD1600, unless otherwise indicated.4. Significance and Use4.1 The purpose of this test method is to obtain the diffuselight transmittance factor of both flat and corrugated translu-cent building
8、 panels by the use of simple apparatus and byemploying as a light source a combination of fluorescent tubeswhose energy distribution closely approximates CIE Source C.5. Apparatus5.1 The apparatus for this test method shall consist of atransmissometer, Fig. 1, comprising essentially the following:5.
9、1.1 Light SourceThe illumination shall consist of twelve20-W fluorescent tubes which are assembled in three banks offour tubes each, according to the following schedule: daylight,deluxe cool white, blue, and daylight.5.1.2 PhotometerThe photometer shall consist of a pho-tocell and of a galvanometer.
10、 The photocell shall be of thebarrier-layer type and shall contain a visual correction filter.The assembly preferably should be hermetically sealed intoplastic as a protection against moisture. The indicating galva-nometer should contain one scale graduated from 0 to 100, anda circuit with sufficien
11、t variable resistance so that the sensitiv-ity of the photometer can be adjusted over the range of 50 to100 footcandles.5.1.3 Test Cabinet, constructed in accordance with thefollowing dimensions.31This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsib
12、ility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved Oct. 1, 2012. Published November 2012. Originallyapproved in 1957. Last previous edition approved in 2008 as D1494 97 (2008)1.DOI: 10.1520/D1494-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
13、orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Detailed working drawings and a bill of materials for this equipment can beobtained at a nominal charge from ASTM Headquarters, 10
14、0 Barr Harbor Drive, POBox C700, West Conshohocken, PA 194282959. Order Adjunct: ADJD1494.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.1.3.1 The transmitted area of
15、 the test specimen shall be610.0 6 1.6 mm by 610.0 6 1.6 mm (24 6116 in. by 24 6116 in.).5.1.3.2 The distance from the bottom of the fluorescenttubes to the bottom of the test specimen shall be 203.0 6 0.8mm (8 6132 in.).5.1.3.3 A 4.8-mm (316-in.) thick, white, standard outdoor,translucent diffusing
16、 plate shall be placed between the lightsource and the test specimen so that the distance from thebottom of the diffusing plate to the bottom of the test specimenis 31.8 6 0.8 mm (114 6132 in.).5.1.3.4 The photocell shall be positioned below the centeraxis of the test specimen so that the distance f
17、rom the bottomof the specimen to the top of the cell is 283.0 6 0.8 mm (11186132 in.).5.1.3.5 A masking plate containing a 31.8-mm (114-in.)diameter hole in its center shall be placed between the testspecimen and the photocell so that the distance from thebottom of the test specimen to the bottom of
18、 the masking plateshall be 233.0 6 0.8 mm (934 6132 in.).6. Standardization of Transmissometer6.1 Center the photocell beneath the 31.8-mm (114-in.)diameter hole in the bottom masking plate. Place the galva-nometer in a flat level position. Ensure that no current flows inthe electrical circuit by op
19、ening the circuit. Adjust the positionof the indicating needle on the galvanometer to read “0 bymeans of the zero adjustment knob. Close the galvanometercircuit. Turn on the illumination in the transmissometer. Wait aminimum of 20 min to permit the transmissometer to reachequilibrium conditions. Adj
20、ust the galvanometer to read“100. The instrument is now ready to be used for measure-ments of diffuse light transmission factor.Metric Equivalentsin. mm in. mm in. mm in. mm132 0.834 19.1 834 222 2434 634316 4.8 114 31.8 934 248 2512 648737 5.6 112 38.1 12 305 28 71114 6.4 2 50.8 14 356 2912 749932
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD14942012STANDARDTESTMETHODFORDIFFUSELIGHTTRANSMISSIONFACTOROFREINFORCEDPLASTICSPANELS 增强 塑料板

链接地址:http://www.mydoc123.com/p-432244.html