ANSI AHRI 275-2010 Application of Outdoor Unitary Equipment A-Weighted Sound Power Ratings《户外统一设备A-重量级声功率应用件》.pdf
《ANSI AHRI 275-2010 Application of Outdoor Unitary Equipment A-Weighted Sound Power Ratings《户外统一设备A-重量级声功率应用件》.pdf》由会员分享,可在线阅读,更多相关《ANSI AHRI 275-2010 Application of Outdoor Unitary Equipment A-Weighted Sound Power Ratings《户外统一设备A-重量级声功率应用件》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/AHRI STANDARD 275-2010 2010 Standard for Application of Outdoor Unitary EquipmentA-Weighted Sound Power Ratings Approved by ANSI on 4 January 2011 ANSI/AHRI Standard 275 ANSI/AHRI STANDARD 275-2010 IMPORTANT SAFETY RECOMMENDATIONS It is strongly recommended that the product be designed, constr
2、ucted, assembled and installed in accordance with nationally recognized safety requirements, appropriate for products covered by this standard. AHRI, as a manufacturers trade association, uses its best efforts to develop standards, employing state-of-the-art and accepted industry practices. However,
3、 AHRI does not certify or guarantee safety of any products, components or systems designed, tested, rated, installed or operated in accordance with these standards or that any test conducted under its standards will be non-hazardous or free from risk. Note: This Standard supersedes AHRI Standard 275
4、-2009. This version of the standard differs from that of 2009 in the following ways: The 2008 edition of AHRI Standard 270 is now used for the rating. Per AHRI Standard 270, the tone adjusted A-Weighted Sound Power Level has been replaced with an overall A-Weighted Sound Power Level. Note: Although
5、this standard is meant as an application for equipment rated per AHRI Standard 270, other standards that provide rating(s) similar to AHRI Standard 270 may be able to use the methodology, techniques and procedures described within this standard. 0 TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .
6、1 Section 2. Scope 1 Section 3. Definitions 1 Section 4. Procedure for Estimating A-Weighted Sound Pressure Level(s) 2 Section 5. Voluntary Conformance 12 TABLES Table 1. Application Factors for Estimating A-Weighted Sound Pressure Level(s) (Equipment Location Factor) 3 Table 2. Application Factors
7、for Estimating A-Weighted Sound Pressure Level(s) (Barrier Shielding Factor) 5 Table 3. Application Factors for Estimating A-Weighted Sound Pressure Level(s) (Sound Path Factor) . . 6 Table 4. Distance Factor. 7 Table 5. Calculation Procedures for Estimating A-Weighted Sound Pressure Level . . 7 Tab
8、le 6. Values Used to Combine Sound Levels for Multi-Unit Installations. 8 FIGURES Figure 1. Corner of Building. 5 Figure 2. Corner of Flat Roof and Wall . 5 Figure 3. Parapet around Flat Roof. 6 Figure 4. Heavy Continuous Wall. 6 Figure 5. Sound Paths According to Table 3. 6 APPENDICES Appendix A. R
9、eferences Normative13 Appendix B. References - Informative.13 Appendix C. Recommended Practices - Informative.14 ANSI/AHRI STANDARD 275-2010 1 APPLICATION OF OUTDOOR UNITARY EQUIPMENT A-WEIGHTED SOUND POWER RATINGS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for outd
10、oor unitary equipment: definitions, procedures for estimating A-Weighted Sound Pressure Levels from the A-Weighted Sound Power Ratings, and recommended application practices. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, con
11、tractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to the outdoor sections of factory-made air-conditioning and heat pump equipment with cooling capacities up to 40kW, as in the sc
12、ope of AHRI Standards 210/240 and 340/360 when rated in accordance with AHRI Standard 270. Section 3. Definitions All terms in this document will follow the standard industry definitions established in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigerat
13、ion, unless otherwise defined in this section. 3.1 Air-Source Unitary Heat Pump. One or more factory-made assemblies which normally include an indoor conditioning coil(s), compressor(s), and outdoor coil(s), including means to provide a heating function. When such equipment is provided in more than
14、one assembly, the separated assemblies shall be designed to be used together, and the requirements of rating outlined in the standard are based upon the use of matched assemblies. 3.1.1 Functions. They shall provide the function of air heating with controlled temperature and may include the function
15、s of air-cooling, air-circulating, air-cleaning, dehumidifying or humidifying. 3.2 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. These values apply to all units of like
16、nominal size and type (identification) produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated ratin
17、g conditions. 3.2.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.2.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.3 Rating Conditions. Any set of operating conditions under whi
18、ch a single level of performance results, and which cause only that level of performance to occur. 3.3.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. ANSI/AHRI STANDARD 275-2010 2 3.4 “Shall,“ “Should,“ “Recommended,“ or “It Is Recomm
19、ended.“ “Shall,“ “should,“ “recommended,“ or “it is recommended“ shall be interpreted as follows: 3.4.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.4.2 Should, Recommended, or It Is Recommended. “Sho
20、uld,“ “recommended,“ or “it is recommended“ is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.5 Sound Power Level, Lw. Ten times the logarithm to the base ten of the ratio of the sound power radiated by the source to a reference sound power, expressed
21、 in decibels (dB). The reference sound power used in this standard is 1 picowatt (pW). 3.5.1 A-Weighted Sound Power Level, LwA. For the purposes of this standard it is the units AHRI 270 A-Weighted Sound Power Level Rating(s). 3.6 Sound Pressure Level, Lp. Twenty times the logarithm to the base ten
22、of the ratio of a given sound pressure to a reference sound pressure of 20 Pa, expressed in decibels (dB). 3.6.1 A-Weighted Sound Pressure Level LpA . The measured level obtained with a sound level meter using its A-weighting network or the level as calculated per this standard. The meter shall meet
23、 the requirements of ANSI Standards S1.4. 3.7 Sound Level Rating(s). The Sound Power Level(s) of the equipment when rated in accordance with AHRI Standard 270. 3.7.1 Standard Sound Rating. The Sound Power Level(s) of the equipment when rated at Standard Rating Conditions in accordance with AHRI Stan
24、dard 270. 3.7.2 Application Sound Rating. The Sound Power Level(s) of the equipment when rated in accordance with AHRI Standard 270 at conditions other than Standard Rating Conditions. 3.8 Unitary Air-Conditioner. One or more factory-made assemblies which normally include an evaporator or cooling co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAHRI2752010APPLICATIONOFOUTDOORUNITARYEQUIPMENTAWEIGHTEDSOUNDPOWERRATINGS 户外 统一 设备 重量级 功率 应用 PDF

链接地址:http://www.mydoc123.com/p-430600.html