1、 AMSC N/A FSC 6620 MIL-PRF-26611F 14 August 2013 SUPERSEDING MIL-PRF-26611E 15 May 1996 PERFORMANCE SPECIFICATION GENERATOR, TACHOMETER GEU-7/A, MINIATURE This specification is approved for use by the Department of the Air Force and is available for use by all Departments and Agencies of the Departm
2、ent of Defense. 1. SCOPE 1.1 Scope. This specification defines a miniature, electric, two-pole, ac tachometer generator for use in generating electrical signals for transmission to aircraft indicating instruments. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specifie
3、d in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that
4、they must meet all specified requirements of the documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications. The following specifications form a part of this document to the extent specified herein. Unless otherwise sp
5、ecified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-7808 - Lubricating Oil, Aircraft Turbine Engine, Synthetic Base MIL-PRF-23699 - Lubricating Oil, Aircraft Turbine Engine, Synthetic Base, NATO Code Number 0-156 INCH-P
6、OUND Comments, suggestions, or questions on this document should be addressed to Oklahoma City Air Logistics Center/ENSDAA, 3001 Staff Drive, Tinker AFB, OK 73145 or emailed to tinker.dsptinker.af.mil. Since contact information can change, you may want to verify the currency of this address informat
7、ion using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-26611F 2 (Copies of these documents are available online at http:/assist.dla.mil/quicksearch/ or from the Standardization Document
8、Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of th
9、is document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. Generators furnished under this specification shall be products that are authorized by the qualifying activity
10、 for listing on the applicable qualified products list before contract award (see 4.2 and 6.3). 3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material mee
11、ts or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle cost. 3.3 Materials. Unless otherwise specified, materials shall be non-magnetic and nonferrous. Materials shall not produce deleterious fumes and shall be treated to resist corrosion due to
12、 electrolytic decomposition, fungus, fuels, salt spray, or any other conditions that may be encountered during operation, use, or storage. 3.4 Interface. 3.4.1 Dimensions. The generator shall conform to the dimensions in Figures 1 and 2. 3.4.2 Electrical connector and mounting. The 2-pin connector f
13、or the generator shall conform to MS33678-12S-3P. The threaded portion of the connector shall be located within 0.375 inch from the rear of the generator. The mounting shall withstand a force of 17 foot-pounds bending movement applied in any direction perpendicular to the longitudinal axis of the co
14、nnector without damage. 3.4.2.1 Connections. The generator winding leads shall be designated B, A, and C (conforming to phases 1, 2, and 3). The B and A leads shall be connected to the B and A pins of the connector and the C lead shall be grounded to the generator frame. Voltage phase rotation is B,
15、 A, and C when rotating the generator drive shaft counterclockwise. 3.4.2.2 Connector shell. The shell shall be electrically grounded to the generator case. In addition, the shell shall be permanently marked FOR USE WITH PERCENT RPM INDICATORS ONLY. The letters shall be at least 0.093 inch high and
16、clearly visible and easily readable on opposite sides of the shell. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-26611F 3 3.4.3 Lubrication resistance. The generator shall be resistant to oil conforming to MIL-PRF-7808 or MIL-PRF-23699. 3.
17、5 Environmental conditions. The generator shall be capable of operation under the following conditions: a. Temperatures ranging from -85 to 450F. b. Vibration up to 20g at frequencies from 5 to 2,000 Hz. c. Relative humidity up to 100 percent. d. Oil temperatures from -50 to 350F. e. Altitude to 80,
18、000 feet. f. An explosive atmosphere without igniting a fuel vapor-laden environment. 3.6 Performance. 3.6.1 Overspeed and reverse operation. The generator shall operate at any speed up to 5,500 rpm in either direction of rotation and in any mounting position. The generator output voltage shall be t
19、hree phase and have a frequency of one cycle per revolution of the generator drive shaft. 3.6.2 Dielectric strength. There shall be no insulation breakdown when a potential of 500 V root mean square (rms) is applied between any electrical pin contact and any metal part of the generator case without
20、the C lead grounded. 3.6.3 Voltage output. The output voltages shall be 21 0.5 when operated at a drive shaft speed of 4,200 rpm and connected to a load consisting of three 40-ohm, Y-connected resistances. None of the output voltages shall be less than 3.5 when operated at a drive shaft speed of 1,0
21、00 rpm and connected to a load consisting of three 20-ohm, Y-connected resistances. 3.6.4 Case. 3.6.4.1 Leakage. The generator case shall withstand oil leakage from the engine into the generator mounting flange at maximum rate of 0.3 inch per hour. 3.6.4.2 Drainage. Oil and combustible fumes shall n
22、ot accumulate in the case. 3.6.5 Shaft. 3.6.5.1 Hardness. Hardness of the drive end of the shaft shall be Rockwell C-30 to C-40. 3.6.5.2 Strength. The shear section of the drive shaft shall withstand 40 5 inch-pounds of torque, and twist through a minimum of 270 degrees before yielding. Provided by
23、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-26611F 4 3.6.5.3 Flexibility. The shaft face shall be capable of moving 0.016 inch in any direction about the generator centerline without rotating or bending the shaft. The shaft rotational backlash about
24、its longitudinal axis shall not exceed 6 angular degrees. Free axial play shall not exceed 0.021 inch. Shaft deflection from the generator centerline shall not exceed 10 degrees. 3.6.6 Weight. The generator shall not exceed 1.2 pounds. 3.6.7 Interchangeability. All parts having the same manufacturer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF26611F2013GENERATORTACHOMETERGEU7AMINIATUREPDF

链接地址:http://www.mydoc123.com/p-428187.html