AIR FORCE A-A-50740 A-2009 SPECTRUM ANALYZER (10 kHz 50 GHz)《(10 kHz-50 GHz)频谱分析仪》.pdf
《AIR FORCE A-A-50740 A-2009 SPECTRUM ANALYZER (10 kHz 50 GHz)《(10 kHz-50 GHz)频谱分析仪》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-50740 A-2009 SPECTRUM ANALYZER (10 kHz 50 GHz)《(10 kHz-50 GHz)频谱分析仪》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to: WR-ALC/742 CBSG, 460 Richard Ray BLVD, Ste 200, Robins AFB, GA 31098-1611. Since contact information can change, you may want to verify the currency o
2、f this address information using the ASSIST Online database at http:/assist.daps.dla.mil . FSC 6625 A-A-50740A 8 July 2009 SUPERSEDING A-A-50740 30 October 1987 COMMERICIAL ITEM DESCRIPTION SPECTRUM ANALYZER (10 kHz 50 GHz) The General Services Administration has authorized the use of this commercia
3、l item description by all federal agencies. 1. SCOPE. This Commercial Item Description(CID) describes a solid-state, internal pre-selection, programmable, 10 Hz resolution bandwidth, 10 kHz to 50 GHz, Spectrum Analyzer including external mixers. This CID is meant as a minimum requirement for the Spe
4、ctrum Analyzer in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. Test equipment offered may be commercially available and may be modified to the extent necessary to meet the following requirements are supplied per this CID. 2. CLASSIFICATIO
5、N. Equipment covered by this CID shall be commercially available equipment and may be modified to the extent necessary to meet the following description. The equipment shall be Class 3, in accordance with MIL-PRF-28800F, except as specified herein. 3. SALIENT CHARACTERISTICS. The equipment shall be
6、capable of operation within the accuracies, limits, and specifications herein. 3.1 Safety and Environmental. The equipment shall meet all safety and environmental requirements as specified in MIL-PRF-28800F for the classification as stated herein except as specified herein. 3.2 Temperature Requireme
7、nts. The temperature ranges for both operating and non- operating conditions shall be as specified for Class 3 equipment in MIL-PRF-28800F. 3.3 Electrical Power Sources. The equipment shall operate from nominal commercial, military, and shipboard power sources of 110/220 Volts AC (+10%) at line freq
8、uencies of 45 Hz to 440 Hz. Power consumption shall not exceed 650 VA. Transient state conditions shall meet MIL-PRF-28800F requirements for Class III equipment. 3.4 Magnetic Environment. The equipment shall comply with the magnetic environment requirements of MIL-PRF-28800F. 3.5 Reliability. The de
9、sign of the equipment shall be such that under normal use and operation the equipment does not fail within 8000 hours of operation with a statistical certainty of 95%. Reinstated after (8 July 2009) and may be used for new and existing designs and acquisitions. INCH-POUND Provided by IHSNot for Resa
10、leNo reproduction or networking permitted without license from IHS-,-,-A-A-50740A 2 3.6 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments. The calibration adjustments, wherever possible, shall be
11、 accessible without removal of the equipment case or modules. The calibration interval shall be a period of one year or greater based on an operating time of 2000 hours. No special tools shall be required for alignment or adjustment except those furnished with the equipment. 3.7 Performance Requirem
12、ents. The equipment shall meet all requirements specified herein, under all combinations of input power conditions, output signal conditions and operating service condition as specified in MIL-PRF-28800F for the class specified herein. 3.7.1 Frequency Range. The minimum frequency range of the Spectr
13、um Analyzer with internal and external mixers shall be 10 kHz to 50 GHz. 3.7.2 Frequency Reference Accuracy. a. Aging rate. After 24 hours warm-up period, the aging shall be less than 1x10-9/day, and less than 2.5x10-7/year. b. Temperature Stability. The temperature stability shall be better than 2x
14、10-8 for any temperature change between 0o C and +55o C. 3.7.3 Center Frequency Accuracy. The center frequency accuracy at 1GHz with 0 span shall be better than +/-50 Hz/day; span/div. controls shall not effect accuracy more than +/-2% for spans less than 1 MHz. 3.7.4 Frequency Counter. The Spectrum
15、 Analyzer shall provide a fully integrated frequency counter capability. The frequency counter accuracy shall allow a 2 GHz signal to be measured within 400 Hz. The total accuracy shall be defined as: +Counter Frequency X Reference Frequency Accuracy + (50 Hz X Harmonic Mixing Number) + 1 LSD. 3.7.5
16、 Frequency Span. The minimum span range shall be 100 Hz to a frequency range of 21 GHz over 10 divisions of the displays horizontal axis. The frequency span accuracy shall be better than +/- 10% over all spans. 3.7.6 Resolution Bandwidth. The resolution bandwidth shall be 10 Hz to 3 MHz (3 or 6 dB).
17、 The setting shall be front-panel selectable or automatic. 3.7.7 Residual FM. The total residual FM shall be less than 10 Hz peak to peak in 20 milliseconds, using a 10 Hz resolution bandwidth in internal mixing for span setting less than or equal to 100 kHz in the phase lock mode. 3.7.8 Frequency D
18、rift. The frequency drift after a 1-hour warm up period shall be less than 50 Hz/min. for frequency span less than 100 kHz. 3.7.9 Sensitivity. The following shall be a minimum acceptable overall sensitivity at 10 Hz resolution bandwidth and lowest harmonic-mixing mode: (Clause does not refer to indi
19、vidual frequency bands.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50740A 3 3.7.10 Sensitivity with Internal Mixer. Frequency Range Sensitivity (dBm) 10 kHz - 50 kHz -95 50 kHz - 1.8 GHz -110 1.8 GHz - 6.4 GHz -122 6.4 GHz - 21 GHz -102 3.7
20、.11 Sensitivity with External Mixer. Frequency Range Sensitivity (dBm) 18 GHz - 26.5 GHz -110 26.5 GHz - 40 GHz -108 33 GHz - 50 GHz -102 3.7.12 Frequency Response. When tuned to the specified frequency range, with attenuator set at 10 dB, the analyzer shall have the following: 3.7.13 Frequency Resp
21、onse with Internal Mixer. Frequency Range Response dB max 10 kHz - 1.8 GHz +/- 1.5 1.8 GHz - 6.4 GHz +/- 2.5 6.4 GHz - 13 GHz +/- 3.5 13 GHz - 18 GHz +/- 4.0 18 GHz - 21 GHz +/- 5.0 3.7.14 Frequency Response with External Mixer. Frequency Range Response dB max 21 GHz - 26.5 GHz +/- 2.5 26.5 GHz - 50
22、 GHz +/- 2.5 3.7.15 Sideband Noise. The Sideband noise shall be -86 dBc/Hz or less at 10 kHz offset from center frequency and in the lowest harmonic mixing mode. 3.7.16 Single Input Range. The minimum amplitude reference level range shall be from -115 dBm to +30 dBm with a safe input of +30 dBm in t
23、he log mode or 1 Watt in the linear mode. 3.7.17 Input Attenuator Accuracy. The input Attenuator shall have a minimum range of 0-60 dB with front panel selectable steps of 10 dB attenuator. The attenuator accuracy shall not exceed 3.0 dB over 60 dB range from 0-18 GHz, and 6.0 dB over the 60 dB rang
24、e overall from 18-21 GHz. 3.7.18 RF Input Connector. For frequencies up to 21 GHz, the RF input connector shall be compatible with the Type N connectors. When mixers are used, the connection shall be through a combination of waveguide mixers, adapters and connectors. The RF input connectors shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA50740A2009SPECTRUMANALYZER10KHZ50GHZ 10 KHZ50GHZ 频谱 分析 PDF

链接地址:http://www.mydoc123.com/p-426865.html