1、Section 6 GROUND ANCHORS 6.1 DESCRIPTION submittal. No work on ground anchors shall begin until working drawings have been approved in writing by the Engineer. Such approval shall not relieve the Contractor of any responsibility under the contract for the successful completion of the work. This work
2、 shall consist of designing, furnishing, in- stalling, testing, and stressing permanent cement-grouted ground anchors in accordance with the plans, these spec- ifications, and the special provisions. 6.2 WORKING DRAWINGS At least 4 weeks before work is to begin, the Contrac- tor shall submit to the
3、Engineer for review and approval complete working drawings and design calculations de- scribing the ground anchor system or systems intended for use. The submittal shall include the following: (1) A ground anchor schedule giving: (a) Ground anchor number, (b) Ground anchor design load, (c) Type and
4、size of tendon, (d) Minimum total anchor length, (e) Minimum bond length, (f) Minimum tendon bond length, and (g) Minimum unbonded length. (2) A drawing of the ground anchor tendon and the corrosion protection system, including details for the following: (a) Spacers separating elements of tendon and
5、 their location, (b) Centralizers and their location, (c) Unbonded length corrosion protection system, (d) Bond length corrosion protection system, (e) Anchorage and trumpet, (f) Anchorage corrosion protection system, (g) Drilled or formed hole size, (h) Level of each stage of grouting, and (i) Any
6、revisions to structure details necessary to accommodate the ground anchor system intended for use. (3) The grout mix design and procedures for placing the grout. The Engineer will approve or reject the Contractors working drawings within 4 weeks of receipt of a complete 6.3 MATERIALS 6.3.1 Prestress
7、ing Steel Ground anchor tendons shall consist of single or mul- tiple elements of prestressing steel, anchorage devices and, if required, couplers conforming to the requirements described in Section 10, “Prestressing.” The following materials are acceptable for use as ground anchor tendons: AASHTO D
8、esignation: M 203 (ASTM Designation ASTM Designation: A 8861A 886M (Indented, 7-wire ASTM Designation: A 882lA 882M (Epoxy coated, A 416 - Uncoated, 7-wire strand) strand) 7-wire strand) 6.3.2 Grout Cement shall be Type I, II, or III Portland Cement con- forming to AASHTO M 85. Cement used for grout
9、ing shall be fresh and shall not contain any lumps or other in- dications of hydration or “pack set.” Aggregate shall conform to the requirements for fine aggregate described in Section 8, “Concrete Structures.” Admixtures may be used in the grout subject to the ap- proval of the Engineer. Expansive
10、 admixtures may only be added to the grout used for filling sealed encapsula- tions, trumpets, and anchorage covers. Accelerators shall not be used. Water for mixing grout shall be potable, clean and free of injurious quantities of substances known to be harmful to Portland cement or prestressing st
11、eel. 507 508 HIGHWAY BRIDGES 6.3.3 6.3.3 Steel Elements Bearing plates shall be fabricated from steel con- forming to AASHTO M 270 (ASTM A 709) Grade 36 minimum, or be a ductile iron casting conforming to ASTM A 536. Trumpets used to provide a transition from the anchor- age to the unbonded length c
12、orrosion protection shall be fabricated from a steel pipe or tube conforming to the re- quirements of ASTM A 53 for pipe or ASTM A 500 for tubing. Minimum wall thickness shall be 0.20 inches. Anchorage covers used to enclose exposed anchorages shall be fabricated from steel, steel pipe, steel tube,
13、or ductile cast iron conforming to the requirements of AASHTO M 270 (ASTM A 709) Grade 36 for steel, ASTM A 53 for pipe, ASTM A 500 for tubing, and ASTM A 536 for ductile cast iron. Minimum thickness shall be 0.10 inches. 6.3.4 Corrosion Protection Elements Corrosion inhibiting grease shall conform
14、to the re- quirements of the Post Tensioning Institutes “Specifica- tions for Unbonded Single Strand Tendons,” Section 3.2.5. Sheath for the unbonded length of a tendon shall con- sist of one of the following: (1) Seamless polyethylene (PE) tube having a mini- mum wall thickness of 60 mils plus or m
15、inus 10 mils. The polyethylene shall be cell classification 334413 by ASTM D 3350. (2) Seamless polypropylene tube having a minimum wall thickness of 60 mils plus or minus 10 mils. The polypropylene shall be cell classification PP21OB55542-11 by ASTM D 4101. (3) Heat shrinkable tube consisting of a
16、radiation crosslinked polyolefin tube internally coated with an adhesive sealant. The minimum tube wall thickness be- fore shrinking shall be 24 mils. The minimum adhesive sealant thickness shall be 20 mils. (4) Corrugated polyvinyl chloride (PVC) tube having a minimum wall thickness of 30 mils. Enc
17、apsulation for the tendon bond length shall consist of one of the following: (1) Corrugated high density polyethylene (HDPE) tube having a minimum wall thickness of 30 mils and conforming to AASHTO M 252 requirements. (2) Deformed steel tube or pipe having a minimum wall thickness of 25 mils. (3) Co
18、rrugated polyvinyl chloride (PVC) tube having a minimum wall thickness of 30 mils. (4) Fusion-bonded epoxy conforming to the require- ments of AASHTO M 284, except that it shall have a film thickness of 15 mils. 6.3.5 Miscellaneous Elements Bondbreaker for a tendon shall consist of smooth plas- tic
19、tube or pipe that is resistant to aging by ultra-violet light and that is capable of withstanding abrasion, impact and bending during handling and installation. Spacers for separation of elements of a multi-element tendon shall permit the free flow of grout. They shall be fabricated from plastic, st
20、eel, or material which is not detri- mental to the prestressing steel. Wood shall not be used. Centralizers shall be fabricated from plastic, steel, or material which is not detrimental to either the prestressing steel or any element of the tendon corrosion protection. Wood shall not be used. The ce
21、ntralizer shall be able to maintain the position of the tendon so that a minimum of 0.5 inches of grout cover is obtained on the tendons, or over the encapsulation. 6.4 FABRICATION Tendons for ground anchors may be either shop or field fabricated from materials conforming to the requirements ofArtic
22、le 6.3. Tendons shall be fabricated as shown on the approved working drawings. The tendon shall be sized so that the maximum test load does not exceed 80% of the minimum guaranteed ultimate strength of the tendon. 6.4.1 Bond Length and Tendon Bond Length The Contractor shall determine the bond lengt
23、h neces- sary to satisfy the load test requirements. The minimum bond length shall be 10 feet in rock, 15 feet in soil or the minimum length shown on the plans. The minimum ten- don bond length shall be 10 feet. 6.4.1.1 Grout Protected Ground Anchor Tendon Spacers shall be placed along the tendon bo
24、nd length of multi-element tendons so that the prestressing steel will bond to the grout. They shall be located at 10-foot maxi- mum centers with the upper one located a maximum of 5 feet from the top of the tendon bond length and the lower one located a maximum of 5 feet from the bottom of the tend
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONIISEC62002DIVISIONIICONSTRUCTIONGROUNDANCHORSERRATA012003 PDF

链接地址:http://www.mydoc123.com/p-417601.html