ACI 440.4R-2004 Prestressing Concrete Structures with FRP Tendons《带有FRP钢筋的预应力混凝土建筑》.pdf
《ACI 440.4R-2004 Prestressing Concrete Structures with FRP Tendons《带有FRP钢筋的预应力混凝土建筑》.pdf》由会员分享,可在线阅读,更多相关《ACI 440.4R-2004 Prestressing Concrete Structures with FRP Tendons《带有FRP钢筋的预应力混凝土建筑》.pdf(39页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 440.4R-04(Reapproved 2011)Prestressing Concrete Structureswith FRP TendonsReported by ACI Committee 440Emerging Technology SeriesISBN 978-0-87031-166-6Prestressing Concrete Structures with FRP TendonsFirst PrintingDecember 2004American Concrete InstituteAdvancing concrete knowledgeCopyright by t
2、he American Concrete Institute, Farmington Hills, MI. All rights reserved. This materialmay not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or otherdistribution and storage media, without the written consent of ACI.The technical committees responsible for
3、 ACI committee reports and standards strive to avoid ambiguities,omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionallyfind information or requirements that may be subject to more than one interpretation or may beincomplete or incorrect. Users wh
4、o have suggestions for the improvement of ACI documents arerequested to contact ACI. Proper use of this document includes periodically checking for errata atwww.concrete.org/committees/errata.asp for the most up-to-date revisions.ACI committee documents are intended for the use of individuals who ar
5、e competent to evaluate thesignificance and limitations of its content and recommendations and who will accept responsibility for theapplication of the material it contains. Individuals who use this publication in any way assume all risk andaccept total responsibility for the application and use of
6、this information.All information in this publication is provided “as is” without warranty of any kind, either express or implied,including but not limited to, the implied warranties of merchantability, fitness for a particular purpose ornon-infringement.ACI and its members disclaim liability for dam
7、ages of any kind, including any special, indirect, incidental,or consequential damages, including without limitation, lost revenues or lost profits, which may resultfrom the use of this publication.It is the responsibility of the user of this document to establish health and safety practices appropr
8、iate tothe specific circumstances involved with its use. ACI does not make any representations with regard tohealth and safety issues and the use of this document. The user must determine the applicability of allregulatory limitations before applying the document and must comply with all applicable
9、laws and regulations,including but not limited to, United States Occupational Safety and Health Administration (OSHA) healthand safety standards.Order information: ACI documents are available in print, by download, on CD-ROM, through electronicsubscription, or reprint and may be obtained by contacti
10、ng ACI.Most ACI standards and committee reports are gathered together in the annually revised ACI Manual ofConcrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgACI 440.4R-04 became effective Sep
11、tember 21, 2004.Copyright 2004, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by anymeans, including the making of copies by any photo process, or by electronic ormechanical device, printed, written, or oral, or recording for sound or visual
12、reproduc-tion or for use in any knowledge or retrieval system or device, unless permission inwriting is obtained from the copyright proprietors.1ACI Committee Reports, Guides, Manuals, and Commentariesare intended for guidance in planning, designing, executing,and inspecting construction. This docum
13、ent is intended for theuse of individuals who are competent to evaluate thesignificance and limitations of its content and recommendationsand who will accept responsibility for the application of thematerial it contains. The American Concrete Institute disclaimsany and all responsibility for the sta
14、ted principles. The Instituteshall not be liable for any loss or damage arising therefrom.Reference to this document shall not be made in contractdocuments. If items found in this document are desired by theArchitect/Engineer to be a part of the contract documents, theyshall be restated in mandatory
15、 language for incorporation bythe Architect/Engineer.Tarek Alkhrdaji Edward R. Fyfe Vistasp M. Karbhari Morris SchupackCharles E. Bakis Ali Ganjehlou James G. Korff David W. ScottP. N. Balaguru Duane J. Gee Michael W. Lee Rajan SenLawrence C. Bank T. Russell Gentry John Levar Mohsen A. ShahawyAbdeld
16、jelil Belarbi Janos Gergely Ibrahim Mahfouz Carol K. ShieldBrahim Benmokrane William J. Gold Henry N. Marsh Khaled A. SoudkiGregg J. Blaszak Nabil F. Grace Orange S. Marshall Robert E. SteffenTimothy E. Bradberry Mark F. Green Amir Mirmiran Gamil TadrosGordon L. Brown Mark Greenwood Ayman S. Mosalla
17、m Jay ThomasVicki L. Brown Doug D. Gremel Antonio Nanni Houssam A. ToutanjiThomas I. Campbell*H. R. Hamilton Kenneth Neale Miroslav VadovicCharles W. Dolan*Issam E. Harik John P. Newhook David VanderpoolDat Duthinh Kent A. Harries Max L. Porter Milan VatovecGarth J. Fallis Mark P. Henderson Mark A.
18、Postma David WhiteAmir Fam Bohdan Horeczko Hayder A. Rasheed*Co-chairs of Subcommittee 440-I.Note: The committee acknowledges the significant contribution of associate member Raafat El-Hacha.Prestressing Concrete Structures with FRP TendonsReported by ACI Committee 440ACI 440.4R-04(Reapproved 2011)E
19、merging Technology SeriesFiber-reinforced polymers (FRPs) have been proposed for use instead ofsteel prestressing tendons in concrete structures. The promise of FRP materialslies in their high-strength, lightweight, noncorrosive, nonconducting, andnonmagnetic properties. This document offers general
20、 information on thehistory and use of FRP for prestressing applications and a description ofthe material properties of FRP. The document focuses on the current stateof design, development, and research needed to characterize and ensure theperformance of FRP as prestressing reinforcement in concrete
21、structures. TheSami H. RizkallaChairJohn P. BuselSecretaryACI encourages the development and appropriate use of new and emerging technologies through the publication of the Emerging TechnologySeries. This series presents information and recommendations based on available test data, technical reports
22、, limited experience with fieldapplications, and the opinions of committee members. The presented information and recommendations, and their basis, may be less fullydeveloped and tested than those for more mature technologies. This report identifies areas in which information is believed to be less
23、fullydeveloped, and describes research needs. The professional using this document should understand the limitations of this document andexercise judgment as to the appropriate application of this emerging technology.proposed guidelines are based on the knowledge gained from worldwideexperimental re
24、search, analytical work, and field applications of FRPsused as prestressed reinforcement. The current development includes abasic understanding of flexure and axial prestressed members, FRP shearreinforcement, bond of FRP tendons, and unbonded or external FRP tendonsfor prestressing applications. Th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI4404R2004PRESTRESSINGCONCRETESTRUCTURESWITHFRPTENDONS 带有 FRP 钢筋 预应力 混凝土 建筑 PDF

链接地址:http://www.mydoc123.com/p-401308.html