ISO 10478-1994 Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy.pdf
《ISO 10478-1994 Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy.pdf》由会员分享,可在线阅读,更多相关《ISO 10478-1994 Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD IS0 10478 First edition 1994-08-01 ANI Internnat Dsc Set Petroleum products - Determination of aluminium and silicon in fuel oils - Inductively coupled plasma emission and atomic absorption spectroscopy methods Prod and a light detector with a 2 Q IS0 IS0 10478:1994(E) suitabl
2、e measuring and readout system. The scale shall be linear in absorbance or in light intensity, or shall be directly in concentration units with curve cor- rection. 5.8 Volumetric flasks, 100 ml and 1 000 ml, com- plying with IS0 1042, class A. 5.9 Pipettes, 1 ml, 2 ml, 5 ml, 10 ml, 20 ml and 25 ml,
3、complying with IS0 648, class A. 5.10 Pipettes, 1 ml and 2 ml, graduated in 0,l ml subdivisions, complying with IS0 835-2. 5.11 Measuring cylinders, 10 ml, 25 ml, 50 ml and 100 ml, with subdivided graduations, complying with IS0 4788. 5.12 Beaker, 400 ml squat form, complying with IS0 3819. 5.13 Fil
4、ter paper, “ashless”, 0,Ol % (m/m) ash maximum. 5.14 Plastic bottles, unfilled virgin plastic, suitable for long-term storage of dilute acid solutions, 100 ml and 1 000 ml. 5.15 Balance, capable of being read to the nearest 0,2 mg. 6 Sample preparation The sample shall be homogenized thoroughly befo
5、re the test portion is taken. Place the sample container in an oven at a temperature between 50 “C and 60 “C and maintain the sample at this temperature until all the sample has melted and reached a uniform viscosity. Insert the shaft of the mixer (5.3) into the sample so that the head of the shaft
6、is immersed to approximately 5 mm from the base of the container. Homogenize the sample for approximately 5 min. In the case of fluid samples which have stood undis- turbed for several months, use a plastic rod to dis- lodge any sediment adhering to the base of the sample container before homogeniza
7、tion. NOTE 2 Failure to use this homogenization procedure will invalidate results, 7 Procedure 7.1 Test portion The mass of test portion taken from the sample (clause 6) shall weigh between 20 g and 50 g, and preferably contain approximately 1,3 mg of alu- minium. NOTE 3 The mass of test portion pro
8、posed, based on the aluminium content, will also suffice for the silicon determi- nation, as both elements are usually found in fuel oils as- sociated with each other. 7.2 Preparation of test solution 7.2.1 Immediately after homogenization transfer the test portion from the homogenized sample to the
9、 weighed platinum basin (5.1); reweigh the basin and contents to the nearest 0,l g to obtain the mass of the test portion taken. 7.2.2 Warm the basin and contents gently with a Bunsen flame until the sample ignites. Maintain the contents of the basin at a temperature such that most of the combustibl
10、e material is removed and only car- bon and ash remain. NOTE 4 If the sample contains considerable amounts of moisture, foaming and frothing may cause loss of sample. If foaming and frothing occur, discard the sample and to a fresh portion add 1 ml to 2 ml of propan-2-01 (4.3) before heating. If foa
11、ming and frothing are not sufficently reduced, add 10 ml of a mixture of toluene/propan-2-01 (4.5) to a further test portion and mix thoroughly. Place several strips of ashless filter paper (5.13) in the mixture and warm gently (when the paper begins to burn, the greater part of the water will have
12、been removed). 7.2.3 Place the basin and contents in the muffle furnace (5.5) preheated to a temperature of 550 “C f 25 “C. Maintain the muffle furnace at this temperature until all the carbon has been removed and only ash remains. NOTE 5 This may require heating overnight. 7.2.4 Cool the basin to r
13、oom temperature and to the contents of the basin add 0,4 g of the flux (4.2) and mix it with the ash. Place the basin and contents for 5 min in a muffle furnace preheated to a temperature of 925 “C f 25 “C. Remove the basin and ensure contact of the flux with the ash. Replace the basin in the muffle
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO104781994PETROLEUMPRODUCTSDETERMINATIONOFALUMINIUMANDSILICONINFUELOILSINDUCTIVELYCOUPLEDPLASMAEMISSIONANDATOMICABSORPTIONSPECTROSCOPYPDF

链接地址:http://www.mydoc123.com/p-1249710.html