UL 3703 CRD-2017 UL standard for safety Solar Trackers - Section Paragraph Reference 6 Mechanical Assembly (reference only) 16 Bonding for Grounding and PERFORMANCE Subject Add ad.pdf
《UL 3703 CRD-2017 UL standard for safety Solar Trackers - Section Paragraph Reference 6 Mechanical Assembly (reference only) 16 Bonding for Grounding and PERFORMANCE Subject Add ad.pdf》由会员分享,可在线阅读,更多相关《UL 3703 CRD-2017 UL standard for safety Solar Trackers - Section Paragraph Reference 6 Mechanical Assembly (reference only) 16 Bonding for Grounding and PERFORMANCE Subject Add ad.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): QIKAStandard Number: UL 3703Standard Title: Standard for Solar TrackersEdition Date: October 8, 2015Edition Number: 1Section / Paragraph Reference: 6 Mechanical Assembly (reference only), 16 Bondingfo
3、r Grounding and PERFORMANCESubject: Add additional requirements for spring clip module securement and pinnedjoints in the bonding path.DECISION:6 Mechanical Assembly6.2 A tracker shall be assembled so that it is not adversely affected by the vibration of normal operation.16 Bonding for Grounding16.6
4、 A connection in the bonding path shall be by a positive means, such as by a clamp, a rivet, a boltedor screwed connection, or by welding, soldering, or brazing with materials having a softening or meltingpoint greater than 455C (850F). The bonding connection shall penetrate nonconductive coatings,
5、suchas paint or vitreous enamel. Ferrous metal parts shall comply with Protection Against Corrosion, Section6. Revolute or pinned joints in the bonding path shall be assessed for positive means according to theSection 62A, Cyclic Load Test.PERFORMANCE62A Cyclic Loading Test62A.1 The provisions of th
6、is section establish a minimum level of fatigue resistance for the structure (see6.2) and bonding path (see 16.6), for units that include revolute or pinned joints.62A.2 The tracking system, composed of the module, module mounting means and supporting structuralmembers shall resist low-cycle fatigue
7、 without a loss in mechanical integrity or loss of bonding path circuitcontinuity, when subjected to a minimum of 15,000 cycles of the alternating load defined in this section.62A.2.1 Mechanical Integrity: The Tracker shall not exhibit evidence of structural or mechanical failure,visual permanent de
8、formation that may adversely affect system safety or compliance, and for any PVmodule securement means including top-down clamps, there shall not be any shifting/movement.62A.2.1.1 The load applied shall be based upon the summed tributary area of the modules defining arepeatable unit, including all
9、functional interfaces of the racking system.62A.2.1.2 If the modules are stowed within 10 of flat/horizontal during high wind speeds (greater than50 mph), the applied loading shall be 10 psf minimum in the negative (downward) direction and 5 psf inthe positive (upward) direction.UL COPYRIGHTED MATER
10、IAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL62A.2.1.3 If the modules are not stowed within 10 of flat/horizontal during high wind speeds, the appliedloading shall be 20 psf in the negative (downward) direction and 10 psf in the positive (upward) direction.Exc
11、eption: Other applied loads (e.g., originating from wind tunnel testing or computational fluid dynamicsmodeling) are allowed if they are clearly stated on the manufacturers technical datasheet and installationinstructions.62A.2.1.4 The load(s) shall be applied as point loads at the center of the mod
12、ule(s), or as distributedload(s) across the modules and the load shall vary cyclically from positive to negative at a frequency notgreater than 2 HZ.62A.2.2 Bonding Path Continuity. Bonding paths shall pass the Bonding Path Resistance Test (below) atthe start and completion and not exhibit loss of c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL3703CRD2017ULSTANDARDFORSAFETYSOLARTRACKERSSECTIONPARAGRAPHREFERENCE6MECHANICALASSEMBLYREFERENCEONLY16BONDINGFORGROUNDINGANDPERFORMANCESUBJECTADDADPDF

链接地址:http://www.mydoc123.com/p-1068096.html