SAE J 2517-2010 Hybrid III Family Chest Potentiometer Calibration Procedure《混合动力III系箱形电位器校准规程》.pdf
《SAE J 2517-2010 Hybrid III Family Chest Potentiometer Calibration Procedure《混合动力III系箱形电位器校准规程》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2517-2010 Hybrid III Family Chest Potentiometer Calibration Procedure《混合动力III系箱形电位器校准规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2016 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/J2517_201608SURFACE VEHICLERECOMMENDED PRACTICEJ2517 AUG2016Issued 2000-06Revised 2010-09Reaf
5、firmed 2016-08Superseding J2517 SEP2010Hybrid III Family Chest Potentiometer Calibration ProcedureRATIONALEJ2517 has been reaffirmed to comply with the SAE five-year review policy.TABLE OF CONTENTS1. SCOPE AND PURPOSE 22. REFERENCES 22.1 Applicable Documents 22.1.1 SAE Publications. 22.2 Related Pub
6、lication . 32.2.1 Federal Publication . 33. CALIBRATION PROCEDURE 33.1 Chest Potentiometer Assembly. 33.2 Calibration Fixture . 33.3 Calibration Procedure . 53.4 Use of the Calibration Coefficients 64. NOTES 64.1 Marginal Indicia . 6APPENDIX A SAMPLE HIII-5F CHEST POTENTIOMETER CALIBRATION VALUES 7F
7、IGURE 1 CALIBRATION FIXTURE SIDE VIEW 4FIGURE 2 CALIBRATION FIXTURE FRONT VIEW 4TABLE 1 CALIBRATION SETUP DIMENSIONS . 5TABLE 2 CALIBRATION POINTS 5SAE INTERNATIONAL J2517 AUG2016 Page 2 of 71. SCOPE AND PURPOSEThis procedure establishes a recommended practice for establishing the sensitivity of the
8、 chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred toas chest compression). A
9、n inherent nonlinearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output
10、) is nonlinear.Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/ (volt/volt) or mm/ (mvolt/volt). These sensitivity values are used to convert recorded voltage measurements to engineering units,
11、in this case chest compression in mm. Some of these techniques intended to correct for the nonlinearity and others did not. Of those that did correct for the nonlinearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testi
12、ng Equipment Committee (DTEC), and led to overall variability in chest compression measurements between laboratories. The intent of this recommended practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round
13、robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin of this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The initial version of SAE J2517 released in May 2000 attempted to f
14、ix this problem by recommending a two-point calibration which was not intended to correct for the nonlinearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also did not require the measurement of a starting position of the potentiometer before each cras
15、h test, thus it did not correct for the difference in starting chest geometry between a subject dummy and its design intent. It was intended to be a simple and reproducible calibration procedure which crash test facilities could easily adopt with little or no modifications to their facilities. In pr
16、actice, most laboratories did not adopt the procedure since it did not correct for the nonlinearities.Recent attempts to reduce dummy-to-dummy and lab-to-lab variations at lower deflection levels (around 25 mm) have renewed interest in adopting a calibration procedure to correct for the nonlinearity
17、 of the measurement system. This current revision of this procedure uses a multipoint calibration with a third order regression to correct for the nonlinearities of the system with a standardized method. It requires changes in the calibration method of the transducer, the data collection procedures
18、when used in a dummy, and the processing procedures after test data is collected. Following this standardized methodology will minimize linearity errors as well as lab-to-lab variations.2. REFERENCES2.1 Applicable Documents2.1.1 SAE PublicationsAvailable from SAE, 400 Commonwealth Drive, Warrendale,
19、 PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J211-1 Instrumentation for Impact TestPart 1Electronic InstrumentationSAE J2570 Performance Specifications for Anthropomorphic Test Device TransducersSAE J2706 Hybrid III Six-Year-Old Child Dummy
20、 Users ManualSAE J2856 Users Manual for the 50th Percentile Male Hybrid III Test DummySAE J2857 Hybrid III 3-Year-Old Child Dummy Users ManualSAE Engineering Aid 25 Users Manual for the Small Adult Female Hybrid III Test DummySAE Engineering Aid 26 Users Manual for the Large Male Hybrid III Test Dum
21、mySAE INTERNATIONAL J2517 AUG2016 Page 3 of 72.2 Related Publication2.2.1 Federal PublicationAvailable from the Superintendent of Documents, U.S. Government Printing Office, Mail Stop: SSOP, Washington, DC 20402-9320.Federal Safety Standards, Motor Vehicle Regulation No. 572, Test Dummies Specificat
22、ionsAnthropomorphic Test Dummy for Applicable Test Procedures.3. CALIBRATION PROCEDURE3.1 Chest Potentiometer AssemblyThe chest potentiometer assembly consists of the potentiometer, potentiometer bracket, arm connector and arm. These components will be treated as an assembly during the calibration p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ25172010HYBRIDIIIFAMILYCHESTPOTENTIOMETERCALIBRATIONPROCEDURE 混合 动力 III 系箱形 电位器 校准 规程 PDF

链接地址:http://www.mydoc123.com/p-1027392.html