SAE AS 22759 183B-2017 WIRE ELECTRICAL POLYTETRAFLUOROETHYLENE POLYMIDE INSULATED SMOOTH SURFACE NORMAL WEIGHT SILVERCOATED COPPER CONDUCTOR 200 VOLTS ROHS.pdf
《SAE AS 22759 183B-2017 WIRE ELECTRICAL POLYTETRAFLUOROETHYLENE POLYMIDE INSULATED SMOOTH SURFACE NORMAL WEIGHT SILVERCOATED COPPER CONDUCTOR 200 VOLTS ROHS.pdf》由会员分享,可在线阅读,更多相关《SAE AS 22759 183B-2017 WIRE ELECTRICAL POLYTETRAFLUOROETHYLENE POLYMIDE INSULATED SMOOTH SURFACE NORMAL WEIGHT SILVERCOATED COPPER CONDUCTOR 200 VOLTS ROHS.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 AEROSPACE STANDARD WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER- COATED COPPER CONDUCTOR, 200 C, VOLTS ROHS AS22759/183Copyright 2017 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval sy
2、stem or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServi
3、cesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED2010-02REVISED2017-09THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8D REV.B FEDERAL SUPPLY CLASS 6145 AS22759 /183 SHEET 1 OF 5 REV. B PROCUREMENT SPECIFICATION: NONE SAE Technical Standards Board Rules provide that: “This report is published by SAEtoad
4、vance thestate of technicaland engineering sciences. The useof this report is entirely voluntary, and its applicability andsuitability for any particularuse, includingany patent infringement arisingtherefrom,is the sole responsibility of theuser.” SAE reviews eachtechnical reportatleast every fiveye
5、ars at whichtime it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS22759/183B RATIONALE SPECIFICATION UPDATED TO INCLUDE AS29606 CONDUC
6、TOR REQUIREMENTS, ROHS RESTRICTIONS, AND AS22759 MODIFICATIONS. THIS CHANGE ALSO INCREASES THE MAXIMUM WEIGHT REQUIREMENTS FOR WIRE SIZES 8 THROUGH 02 TO ACCOUNT FOR INCREASED CIRCULAR MIL AREA (CMA) ADOPTED IN AS29606. AS22759 IS A CONVERTED MILITARY SPECIFICATION ORIGINALLY NOTED AS MIL-W-22759 CR
7、EATED IN 1971. CONDUCTOR REQUIREMENTS WERE ORIGINALLY DEFINED BY ASTM B3, B298, AND B355 FOR TIN, SILVER, AND NICKEL PLATE RESPECTIVELY. THESE SPECIFICATIONS CONTROLLED THE CONDUCTOR BY ESTABLISHING STRAND SIZE, CONDUCTOR SIZE, AND MAXIMUM DCR (DIRECT CURRENT RESISTANCE). BY THE LATE 1980S, CONDUCTO
8、R PRODUCERS WERE PRODUCING TIGHT TOLERANCE CONDUCTORS WHICH WERE MADE AT THE MINIMUM DIMENSIONAL AND MAXIMUM DCR LIMITS OF THE SPECIFICATION TO REDUCE THE WEIGHT (MASS) OF THE FINALLY INSULATED WIRE. BY THE EARLY 1990S, THE TIGHT TOLERANCE CONDUCTORS WERE PREVALENT THROUGHOUT AEROSPACE. ABOUT THE SA
9、ME TIME, LARGE GAUGE SIZE CONDUCTORS (SIZE 8 THROUGH 4/0) STARTED EXHIBITING CRIMP FAILURES IN TERMINAL LUGS MOUNTED ON AIRCRAFT GENERATORS. SINCE THESE CIRCUITS ROUTED PRIMARY ELECTRICAL POWER FROM THE GENERATOR TO THE MAIN POWER DISTRIBUTION CENTERS, CRIMP DEGRADATION RESULTING IN DISRUPTION OF EL
10、ECTRICAL POWER CAUSED SIGNIFICANT CONCERN. SEVERAL OEMS, AS WELL AS NAVY AND AIR FORCE LABORATORIES, INVESTIGATED THE FAILURES AND DETERMINED THAT THE FAILED CRIMPS WERE DUE TO A COMBINATION OF LOW CMA, HIGH VIBRATION, AND THERMAL CYCLING. ADDITIONAL TESTING ESTABLISHED MINIMUM CMA LEVELS WHICH WOUL
11、D PREVENT THE CRIMP FAILURES. THESE NEW LIMITS WERE OFFERED TO ASTM BUT REJECTED. NAVAIR THEN PRODUCED AN ENGINEERING POSITION LETTER (EPL) TO MANDATE THE INCREASED CMAS ON STRANDING USED IN AS22759 CONSTRUCTIONS. NAVAIR THEN CREATED MIL-W-29606 WHICH WAS INTENDED TO REPLACE THE ASTM SPECIFICATIONS
12、AS THE REQUIRED CONDUCTOR SPECIFICATION. BEFORE THE MIL-W-29606 COULD BE ADDED TO MIL-W-22759, THE SPECIFICATION TRANSITION AND ADOPTION TOOK PLACE CONVERTING THE DOCUMENTS FROM MILITARY SPECIFICATIONS TO AS DOCUMENTS IN THE 1999 TO 2000 TIME FRAME. SINCE THE EPL NO LONGER HAD LEGAL STANDING AFTER T
13、HE CONVERSION, WIRE PRODUCERS DID NOT HAVE TO ABIDE BY THE RESTRICTIONS WHICH ALLOWED THIS ISSUE TO CREEP BACK INTO THE PRODUCTS FROM TIME TO TIME. IN 2011, THE SAE AE-8D COMMITTEE OPENED A PROJECT TO UPDATE THE AS22759 AND ITS ASSOCIATED DETAILED SPECIFICATION SHEETS. WHEN LOOKING AT THIS ISSUE, TH
14、E COMMITTEE DECIDED TO ADOPT MIL-W-29606 (NOW AS29606) AND REPLACE THE ASTM REQUIREMENTS WITH THE AS29606 REQUIREMENTS. SINCE THE DIAMETER RANGE OF THE CONDUCTOR STRANDS NEEDED TO SHIFT SLIGHTLY TO THE RIGHT TO MEET THE NEW MINIMUM CMA REQUIREMENTS, OVERALL PRODUCT WEIGHT MAXIMUMS SHIFTED ABOUT 3 TO
15、 5%. THE COMMITTEE EVALUATED SEVERAL METHODS OF INCORPORATING THIS CHANGE, INCLUDING CANCELING AND SUPERSESSION, BUT THE END USERS DID NOT WANT TO CHANGE PART NUMBERS FOR PRODUCTS WHICH HAVE BEEN USED IN AEROSPACE AND INDUSTRY FOR OVER 40 YEARS AND IS CURRENTLY ON THOUSANDS OF DRAWINGS. SINCE THESE
16、PRODUCTS ARE PRIMARILY USED FOR PRIMARY POWER DISTRIBUTION FROM THE GENERATORS TO THE MAIN DISTRIBUTION PANELS, THE WEIGHT INCREASE TO THE ELECTRICAL INTERCONNECT SYSTEM IS CONSIDERED INSIGNIFICANT. SINCE THIS CHANGE DOES AFFECT THE MAXIMUM WEIGHT LIMITS FOR SIZES 8 THROUGH 4/0, END USERS SHOULD VER
17、IFY THAT THE NEW WEIGHT RANGES MEET THE DESIGN REQUIREMENTS OF LEGACY APPLICATIONS. NOTICE THE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759. AEROSPACE STANDARD AS22759 /183 SHEET 2 OF 5 REV. B WIRE, ELECTRICAL, POLYTE
18、TRAFLUOROETHYLENE/POLYMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER- COATED COPPER CONDUCTOR, 200 C, VOLTS ROHS FP / POLYIMIDE / FP TAPE FP TAPE FP TAPE META-ARAMID FIBER BRAID TREATED TO PREVENT FRAYING 1/ SIZE 8 THROUGH 6 FP / POLYIMIDE / FP TAPE FP TAPE FP TAPE FP TAPE META-ARAMID FIBER B
19、RAID TREATED TO PREVENT FRAYING 1/ SIZE 4 THROUGH 04 FP FLUOROCARBON POLYMER MODIFIED POLYTETRAFLUOROETHYLENE (PTFE) CONDUCTOR STRANDED SILVER COATED COPPER 1/ BRAID: BRIGHT AROMATIC POLYAMIDE YARN, 200 DENIER, 100 FILAMENTS, TIGHTLY FORMED, UNIFORM IN APPEARANCE, TREATED WITH A CLEAR FINISHER COATI
20、NG. THE FINISHER COATING SHALL BE COMPATIBLE WITH THE TEMPERATURE RATING AND PERFORMANCE REQUIREMENTS OF THE INSULATED WIRE. BRAID SHALL GRIP THE UNDERLYING INSULATION SUFFICIENTLY AS TO NOT SLIDE ALONG THE TAPE SURFACE DURING NORMAL HANDLING. FIGURE 1 - AS22759/183 CONFIGURATION AEROSPACE STANDARD
21、AS22759 /183 SHEET 3 OF 5 REV. B WIRE, ELECTRICAL, POLYTETRAFLUOROETHYLENE/POLYMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER- COATED COPPER CONDUCTOR, 200 C, VOLTS ROHS TABLE 1 - CONSTRUCTION DETAILS FOR FINISHED WIRE PART NO. 1/ WIRE SIZE CONDUCTOR 4/ FINISHED WIRE 3/ STRANDING (NUMBER OF S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS22759183B2017WIREELECTRICALPOLYTETRAFLUOROETHYLENEPOLYMIDEINSULATEDSMOOTHSURFACENORMALWEIGHTSILVERCOATEDCOPPERCONDUCTOR200VOLTSROHSPDF

链接地址:http://www.mydoc123.com/p-1023840.html