SAE ARP 433A-2001 Liquid Oxygen Quantity Instruments《液态氧气定量仪器》.pdf
《SAE ARP 433A-2001 Liquid Oxygen Quantity Instruments《液态氧气定量仪器》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 433A-2001 Liquid Oxygen Quantity Instruments《液态氧气定量仪器》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、AEROSPACE RECOMMENDED PRACTICEARP433 REV.AIssued 1958-07Reaffirmed 2008-02Revised 2001-09Superseding ARP433Liquid Oxygen Quantity InstrumentsFOREWORDChanges in this Revision are format/editorial only.1. SCOPE:This Aeronautical Recommended Practice covers Liquid Oxygen Quantity Indicators for use wit
2、h associated Liquid Oxygen converters.1.1 Purpose:To recommend requirements for electrical Liquid Oxygen Quantity Instruments for use in aircraft, the operation of which may subject the instruments to the environmental conditions specified in Paragraph 3.3.2. REFERENCES:NACA Report 12353. GENERAL RE
3、QUIREMENTS:3.1 Materials and Workmanship:3.1.1 Materials: Materials should be of a quality which experience and/or tests have demonstrated to be suitable for use in aircraft instruments.3.1.2 Workmanship: Workmanship should be consistent with high-grade aircraft instrument manufacturing practice.SAE
4、 Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom,
5、 is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication may be
6、 reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax:
7、 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE ARP433 Revision A- 2 -3.2 Identification:The following information should be legibly and permanently marked on the instrument or attached thereto:a. Name of instrument - Liquid Oxygen Quantity Instrumentb. SAE Aeronau
8、tical Recommended Practice ARP433Ac. Manufacturers part numberd. Manufacturers serial number or date of manufacturee. Manufacturers name and/or trademarkf. Rangeg. Rating3.3 Environmental Conditions:The following conditions have been established as design requirements only. Tests should be conducted
9、 as specified in Sections 5, 6, and 7.3.3.1 Temperature: When installed in accordance with the instrument manufacturers instructions, the instrument should function over a range of ambient temperature from -55 C to 70 C. It should not be adversely affected by exposure to temperatures of -65 C to 80
10、C.3.3.2 Humidity: The instrument should function and not be adversely affected when exposed to any relative humidity in the range of 0 to 95% at any temperature up to 70 C.3.3.3 Vibration: When installed in accordance with the instrument manufacturers instructions, the instrument should function and
11、 should not be adversely affected when subjected to vibrations of the following characteristics:TABLE 1Typeof MountingCyclesper SecondMaximum DoubleAmplitude (Inches)MaximumAccelerationFuselage Forward 5 to 500 .036 2 Gof Spar AreaPanel or Rack 5 to 500 0.020 2 G(with shockmounts)SAE ARP433 Revision
12、 A- 3 -3.3.4 Altitude: The instrument should function and should not be adversely affected when subjected to a pressure and temperature range equivalent to -1000 to 50,000 feet standard altitude, per NACA Report 1235 except as limited by application of Paragraph 3.3.1. The instrument should not be a
13、dversely affected when subjected to a pressure of 50 inches Hg absolute.3.4 Fire Hazard:The electrical circuit should be so designed that the potentials should not create a fire hazard in the aircraft. The design of the circuit should be such that the current in the leads to the converter sensing el
14、ement should in no case exceed 0.2 amperes.3.5 Radio Interference:The instrument should not be the source of objectionable interference, under operating conditions at any frequencies used on aircraft, either by radiation or feedback, in radio equipment installed in the same aircraft as the instrumen
15、ts.3.6 Magnetic Effect:The magnetic effect of the indicator should not adversely affect the operation of other instruments installed in the same aircraft.3.7 Converter Capacitance:The instrument assembly should be designed for operation from the following input capacitances:a. Capacitance for variou
16、s size empty converters is in accordance with the linear relationship shown in Table 2.b. Capacitance for converters containing liquid oxygen should be calculated as follows:C = Ce + 5.796VC = Total capacitance (uuf)Ce = Capacitance of empty converter (uuf)V = Volume of liquid oxygen in converter (l
17、iters)TABLE 2Converter Capacitor(liters) Capacitance of EmptyConverter (uuf) 5 63.510 123.525 303.5SAE ARP433 Revision A- 4 -4. DETAIL REQUIREMENTS:4.1 Rating:4.1.1 Electrical: The instrument should be designed to operate on 11510 percent variation in AC voltage, and 4005 percent variation in freque
18、ncy.4.2 Indication:The quantity instrument should be of the null balancing three wire capacitance bridge type.4.2.1 Visibility: The indicating means and all significant markings should be readable from any point within the frustum of a cone whose side makes an angle of not less than 30 degrees with
19、the perpendicular to the dial, and whose small diameter is the aperture of the instrument case. The distance between the dial and the cover glass should be a practical minimum and should not exceed 0.250 of an inch.4.2.2 Indicator Case: The case should conform to Air Force-Navy Aeronautical Standard
20、 or a Military Standard such as: AND10412, MS33549, etc. The case should be hermetically sealed.4.2.3 Filling Medium: The case should be filled with an inert gas, at least 10 percent helium, if at least 98 percent purity, free of dust particles, and sufficiently dry so that fogging of the dial glass
21、 does not occur during the low temperature tests of this ARP.4.2.4 Dial:4.2.4.1 Finish: Unless otherwise specified by the user, matte white material should be applied to all major graduations, numerals, and indicating means. Non-functional surfaces should be durable dull black.4.2.4.2 Scale Length:
22、The dial scale length shall be 180 angular degrees, minimum.4.2.4.3 Graduations: The intervals employed should be determined by the associated converter in order to have a scale with sufficient graduations and numerals for each reading without overcrowding.4.2.4.4 Numerals: Sufficient numerals shoul
23、d be marked to positively identify all graduations.4.2.4.5 Instrument Name: The words “Liquid Oxygen“ and “Liters“ should appear on the dial.4.2.5 Low Level Indications: A preset switch may be incorporated in the indicator to actuate an external warning light.4.2.6 Power Indication: A means should b
24、e provided to permit checking operation of the indicator such as connections to an external test switch.5. TEST CONDITIONS:SAE ARP433 Revision A- 5 -5.1 Atmospheric Conditions:Unless otherwise specified, all tests required by this ARP should be made at atmospheric pressure of approximately 29.92 inc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP433A2001LIQUIDOXYGENQUANTITYINSTRUMENTS 液态 氧气 定量 仪器 PDF

链接地址:http://www.mydoc123.com/p-1022945.html