SAE AIR 1660B-1997 Fuel Level Control Valves Systems《燃油液位控制阀 系统》.pdf
《SAE AIR 1660B-1997 Fuel Level Control Valves Systems《燃油液位控制阀 系统》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 1660B-1997 Fuel Level Control Valves Systems《燃油液位控制阀 系统》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and enginee ring sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefr
2、om, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invit es your written comments and suggestions.Copyright 1997 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.
3、S.A.QUESTIONS REGARDING THIS DOCUMENT: (412) 772-8510 FAX: (412) 776-0243TO PLACE A DOCUMENT ORDER: (412) 776-4970 FAX: (412) 776-0790SAE WEB ADDRESS http:/www.sae.org400 Commonwealth Drive, Warrendale, PA 15096-0001AEROS PACE INFORM ATION REPORTSubmitted for recognition as an American National Stan
4、dardAIR1660 RE V. BIssued 1981-06Revised 1997-12Superseding AIR1660AF uel L evel C ontrol V alves /S ystemsFOREWORDChanges in this revision are format/editorial only.1. SCOPE:A fuel level control valve/system controls the quantity of fuel in a tank being filled or emptied. This document provides a g
5、eneral familiarization with these mechanisms (e.g. forms they take, functions, system design considerations). This document provides the aircraft fuel system designer with information about these mechanisms/devices, so that he can prescribe the types of level control valves/systems which are best su
6、ited for his particular fuel system configuration.2. APPLICABLE DOCUMENTS:The following publication forms a part of this document to the extent specified herein and is available from SAE, Inc., 400 Commonwealth Drive, Warrendale, PA 15096:AIR1615 Thesaurus for Fuel System Components3. TYPES:Generall
7、y, it is desired to have a relatively high time-rate-of-change of fuel quantity in fuel tanks, so rather large line sizes and valves are used (up to 6-inch diameter lines and 3-inch diameter level control valves, in some cases). This dictates the use of a large shutoff valve; the most efficient meth
8、od of controlling this “large” shutoff valve is by the use of a relatively small pilot valve. The pilot valve is directly influenced by the liquid level to be controlled, and the shutoff valve is controlled by the pilot valve. When the shutoff valve and pilot valve are in the same package, it is cal
9、led an integral level control valve, and, when the pilot valve and shutoff valve are not in the same package, it is called a remote-sensing level control system.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license fro
10、m IHS-,-SAE AIR1660 Revision B- 2 -3.1 Types of Shutoff Valves:Diaphragm Type - The operator is a flexible membrane.Piston Type - The operator is a piston.Tank-Mounted - The valve has one port (inlet or outlet) open to the tank. This port will not accommodate the attachment of a conduit.Line-Mounted
11、 - The valve has inlet and outlet ports both of which can accommodate the attachment of conduits. (Note: this type may be located inside a fuel tank, but it is not a tank-mounted type.)Normally-Open - This type opens when pressure is applied in the applicable direction. (Note: this type may be close
12、d when at rest with no pressure applied.) The cracking/opening pressure can be specified.Normally-Closed - This type closes or remains closed when pressure is applied in the applicable direction.Hydromechanical - Mode control is accomplished by blocking/opening the pilot port(s) or by applying/remov
13、ing pressure to/from the pilot port(s).Electromechanical - Mode control is accomplished by introduction/removal of an electric signal.Plug-In - Refers to types that can be installed/removed into/from tanks or lines without disconnecting the aircraft conduit connections and with minimal leakage from
14、the undrained tanks/lines.Integral - The shutoff valve and sensing element are in one package (i.e. one part number).Remote - The shutoff valve and sensing element are in individual packages (i.e. two or more part numbers). The shutoff valve and sensing element(s) are connected by the user.Copyright
15、 SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE AIR1660 Revision B- 3 -3.2 Types of Sensing Elements:Float Valve - A small shutoff valve that gains mode control by submergence or unsubmergence in liquid.Flo
16、at Switch - An electric switch that gains mode control by submergence or unsubmergence in liquid.Fluidic Level-Sensor - A pressure transmitter that transmits pressure when submerged in a gas and does not transmit pressure when submerged in a liquid.Miscellaneous - Fuel quantity gaging systems can pr
17、ovide electrical signals at predetermined fuel quantities to control the mode of the shutoff valve. Fiber-optic devices discriminate between the indices of refraction of gases and liquids and respond with appropriate electric signals for mode control of the shutoff valve.4. DEFINITIONS:AIR1615 - THE
18、SAURUS FOR FUEL SYSTEM COMPONENTS contains many definitions that are applicable to level control valves/systems. The following definitions are those commonly used to describe the design features of level control valves/systems.Operator - The dynamic element which when pressure is applied to it urges
19、 the poppet in the desired direction (open or closed).Overbalance - The ratio of the force (or moment) tending to close the shutoff valve to the force (or moment) tending to open the shutoff valve.Overshoot - The volume of liquid that passes through the shutoff valve after the shutoff valve has been
20、 signaled to close.Sensing Level - The liquid level at which the sensing element is actuated.Final Level - The liquid level after final closure of the shutoff valve; this level is a function of the liquid surface area versus the liquid height above/below the sensing level. This differs from the sens
21、ing level because of the influence of the overshoot of the shutoff valve.Surge-Pressure Relief - Surge-pressure suppression accomplished by limiting the pressure in the operator chamber of the shutoff valve (usually accomplished by the use of a small, spring-loaded relief valve). When this scheme is
22、 used, the shutoff valve will reopen when excessive pressure is introduced at the inlet.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE AIR1660 Revision B- 4 -4. (Continued):Surge-Pressure Control
23、- Surge-pressure suppression accomplished by controlling the flowrate of liquid into the operator chamber in a fashion to control the time-rate-of-change of poppet position with respect to the seat. This scheme is also called “variable-orifice surge control”, and, when this scheme is used, the shuto
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR1660B1997FUELLEVELCONTROLVALVESSYSTEMS 燃油 控制 系统 PDF

链接地址:http://www.mydoc123.com/p-1020054.html