REG UFGS-26 56 36 00 40-2013 FLOOD LIGHTING.pdf
《REG UFGS-26 56 36 00 40-2013 FLOOD LIGHTING.pdf》由会员分享,可在线阅读,更多相关《REG UFGS-26 56 36 00 40-2013 FLOOD LIGHTING.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-26 56 36.00 40 (February 2013)-Preparing Activity: NASA SupersedingUFGS-26 56 36.00 40 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2013*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 56 36
2、.00 40FLOOD LIGHTING02/13PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 ADMINISTRATIVE REQUIREMENTS1.3.1 Pre-Installation Meeting1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Drawing Requirements1.5.1.1 Luminaire Drawings1.5.2 Design Data for Luminaires1.5.3 Standard Products1.5.3.1 Alternative Qualifica
3、tions1.5.3.2 Material and Equipment Manufacturing Date1.6 SUSTAINABLE DESIGN REQUIREMENTS1.6.1 Local/Regional Materials1.6.2 Environmental Data1.6.3 Energy Efficiency1.7 SUPPORT SERVICEPART 2 PRODUCTS2.1 PRODUCT COORDINATION2.2 PRODUCT STANDARDS2.3 FLOODLIGHTING LUMINAIRES2.4 FLUORESCENT FLOODLIGHTS
4、, EXTERIOR2.5 HIGH-INTENSITY-DISCHARGE (HID) LUMINAIRES2.5.1 Mounting Devices2.5.2 Focusing, Fusing,and Connecting2.6 QUARTZ-IODINE LUMINAIRES, SPECIAL PURPOSE2.6.1 Housing, Reflectors, and Lamps2.7 SUBSTATION-YARD LIGHTING LUMINAIRES2.7.1 Pole Mounting2.7.2 Reflector Assembly2.7.3 Wiring2.8 LAMP BA
5、LLASTSSECTION 26 56 36.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.9 SERIES CIRCUIT TRANSFORMERS2.10 LAMPS2.10.1 HID Lamps2.10.2 Low-Pressure Sodium2.10.3 High-Pressure Sodium2.10.4 Metal Halide2.10.5 Incandescent Lamps2.11 EQUIPMEN
6、T IDENTIFICATION2.11.1 Manufacturers Nameplate2.11.2 Labels2.12 FACTORY APPLIED FINISHPART 3 EXECUTION3.1 INSTALLATION3.2 FIELD TESTING3.3 WARRANTY- End of Section Table of Contents -SECTION 26 56 36.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
7、m IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-26 56 36.00 40 (February 2013)-Preparing Activity: NASA SupersedingUFGS-26 56 36.00 40 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2013*SECTION 26 56 36.00 40FLOOD LIGHTING02/13*NOTE: This gu
8、ide specification covers the requirements for floodlighting fixtures and energy efficient lamps.Show a three-dimensional detail of each fixture on the drawings, with letter designation keyed to the drawings and electrical symbols describing the type, style, class, kind, and size of fixture as follow
9、s:Floodlighting fixtures, including luminaries for NEMA Type 2, 3, 4, 5, 6, and 7 beam-spread distribution patterns.On all fixture drawings indicate the materials and finishes for reflectors, refractors, diffusers, and shielding; fixture mounting details; the number, size, and description of lamps;
10、and electrical characteristics of branch-circuit or feeder connections.Use Section 26 09 23.00 40 LIGHTING CONTROL DEVICES for control devices (includes tailoring for exterior lighting).Use Section 26 56 13.00 40 LIGHTING POLES AND STANDARDS for pole or standard, including mounting and base accessor
11、ies of exterior fixtures.Use Section 26 56 19.00 40 ROADWAY LIGHTING for roadway and street lighting.Use Section 26 56 23.00 40 AREA LIGHTING for general exterior lighting.Use Section 26 55 53.00 40 SECURITY LIGHTING for security and CCTV area lighting.Adhere to UFC 1-300-02 Unified Facilities Guide
12、 Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide SECTION 26 56 36.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-specification for project speci
13、fic requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this
14、 guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: This section contains the following sketches (Graphics) and are available in metric (SI) and U.S. Customary (IP) syste
15、m dimensions. Sketch titles and style numbers are unchanged for both types. The metric values indicated are a conversion of U.S. Customary (IP) system dimensions.Do not include list of sketches, or sketches themselves, in project specifications. Use luminaire sketches as details on drawings whenever
16、 possible. If special features are required, do not modify sketches, but indicate these changes as notes in fixture schedule. The “XL“ style numbers and dates should remain on the drawing details.Sketch No. TitleXL-2 FloodlightXL-3 Floodlight and Sports LightXL-28 Luminaire Mounting BracketsNOTE: Do
17、 not include this index in project specification.*NOTE: Show the following information on the drawings or specify in the project specifications:a. Luminaire schedule and indicate pertinent information; i.e., mounting, lamps, ballasts, and voltage.1. Type of luminaire;2. Voltage, wattage, and frequen
18、cy rating required;3. Accessories required, such as photocell, time switches, and auxiliary lamps;SECTION 26 56 36.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Location of poles or standards;5. Referenced sketch; and6. Extent and lo
19、cation of the work to be accomplished and wiring and equipment necessary for a complete installation.*NOTE: Demolition work that involves disposal of fluorescent and HID lamps and ballasts will require the use of Section 02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs AND MERCURY.*P
20、ART 1 GENERAL*NOTE: Including building energy performance language within this specification signals a commitment to design, build, and operate a building with superior energy performance-one whose energy use, greenhouse gas emissions, and costs-to-operate are lower than 75 percent of comparable bui
21、ldings nationwide.Designers are encouraged to include the latest EPA/DOE “Energy Star“ applicable lighting fixtures and lamps in the design, for both existing and new facilities.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The pu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS26563600402013FLOODLIGHTINGPDF