REG NASA-LLIS-0404-1996 Lessons Learned - Traveling Wave Tube Amplifier on Martian Surface Failure Due to Corona (1976).pdf
《REG NASA-LLIS-0404-1996 Lessons Learned - Traveling Wave Tube Amplifier on Martian Surface Failure Due to Corona (1976).pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-0404-1996 Lessons Learned - Traveling Wave Tube Amplifier on Martian Surface Failure Due to Corona (1976).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 0404Lesson Info:a71 Lesson Number: 0404a71 Lesson Date: 1996-04-26a71 Submitting Organization: JPLa71 Submitted by: J.A. RobertsSubject: Traveling Wave Tube Amplifier on Martian Surface: Failure Due to Corona (1976) Abstract: When commanded to switch on, TWTA No. 1 on Viking L
2、ander 2 failed to produce an S-band RF downlink, probably due to RF breakdown of the high-voltage power converter. High-voltage circuits designed to operate within the Martian atmosphere require special design precautions, such as insulation from ground potential, to avoid corona or other forms of h
3、igh-voltage breakdown.Description of Driving Event: (Relevant Historical Lessons Learned)Traveling Wave Tube Amplifier (TWTA) No. 1 on Viking Lander 2 failed to produce an S-band RF downlink when commanded “ON“ October 13, 1976. The most probable failure model is that the high-voltage power converte
4、r developed a corona breakdown. A subsequent attempt to operate this TWTA during the extended mission late in 1978 also failed to produce downlink.From Martian day one (SOL 1) after Lander 2 touchdown, TWTA No. 2 had been used and it had performed very well. On SOL 33, the link was switched to TWTA
5、No. 1 because it ran cooler than No. 2, and the increasing solar angle was beginning to raise the Lander ambient temperature. TWTA No. 1 produced normal carrier and telemetry sidebands; however, the ranging subcarrier was suppressed by noise by 6 to 8 dB. These symptoms continued from SOL 33 to SOL
6、38. On SOL 39, no signal was observed at the Deep Space Stations after the TWTA “ON“ command. Subsequent telemetry via the UHF relay link (not involved) showed the TWTA bay temperature did not make its usual climb. The TWTA went through its 90-second cathode warm-up period, and the failure must have
7、 occurred shortly after the high-voltage was programmed to come on.Other failure mechanisms examined and discarded include: sequence error, spurious signals on the Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-uplink from the stations, “power-on“ s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS04041996LESSONSLEARNEDTRAVELINGWAVETUBEAMPLIFIERONMARTIANSURFACEFAILUREDUETOCORONA1976PDF

链接地址:http://www.mydoc123.com/p-1018051.html