1、National Fire Alarm and Signaling Code HandbookBK-NFPA-72HB16-150223-FM.indd 1 9/14/2015 8:16:32 PMBK-NFPA-72HB16-150223-FM.indd 2 9/14/2015 8:16:32 PMNational Fire Alarm and Signaling Code Handbook2016 EditionEdited byRichard J. Roux Senior Electrical Specialist, NFPAChristopher D. CoacheSenior Ele
2、ctrical Engineer, NFPANatioNal Fire ProtectioN associatioNthe leading information and knowledge resource on fire, electrical and related hazardsBK-NFPA-72HB16-150223-FM.indd 3 9/14/2015 8:16:34 PMProduct Management: Debra RoseDevelopment and Production: Kenneth RitchieCopyediting: Janet ProvostArt D
3、irection: Cheryl Langway Permissions: Josiane DomeniciCover Design: Cameron, Inc.Interior Design: Cheryl LangwayComposition: Cenveo Publisher ServicesManufacturing: Ellen GliskerPrinting/Binding: R.R. Donnelley/WillardCopyright 2015National Fire Protection AssociationOne Batterymarch ParkQuincy, Mas
4、sachusetts 02169-7471All rights reserved.Important Notices and Disclaimers: Publication of this handbook is for the purpose of circulating information and opinion among those concerned for fire and electrical safety and related subjects. While every effort has been made to achieve a work of high qua
5、lity, neither the NFPAnor the contributors to this handbook guarantee or warrantee the accuracy or completeness of or assume any liability in connection with the information and opinions contained in this handbook. The NFPA and the contributors shall in no event be liable for any personal injury, pr
6、operty, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, or reliance upon this handbook.This handbook is published with the understanding that the NFPA and the contributors to this han
7、dbook are supplying information and opinion but are not attempting to render engineering or other professional services. If such services are required, the assistance of an appropriate professional should be sought.NFPA 72, National Fire Alarm and Signaling Code (“NFPA 72”), is, like all NFPA codes,
8、 standards, recom-mended practices, and guides (“NFPA Standards”), made available for use subject to Important Notices and Legal Disclaimers, which appear at the end of this handbook and can also be viewed at www.nfpa.org/disclaimers.Notice Concerning Code Interpretations: This 2016 edition of the N
9、ational Fire Alarm and Signaling Code Handbook Handbook is based on the 2016 edition of NFPA 72. All NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) are developed in accordance with the published procedures of the NFPA by technical committees comprised of volunteers drawn
10、 from a broad array of relevant interests. The handbook contains the complete text of NFPA72 and any applicable Formal Interpretations issued by the NFPA at the time of publication. This NFPA Standard is accompanied by explanatory commentary and other supplementary materials.The commentary and suppl
11、ementary materials in this handbook are not a part of the NFPA Standard and do not constitute Formal Interpretations of the NFPA (which can be obtained only through requests processed by the responsible technical committees in accordance with the published procedures of the NFPA). The commentary and
12、 supplementary materials, therefore, solely reflect the personal opinions of the editor or other contributors and do not necessarily represent the official position of the NFPA or its technical committees.Reminder: Updating of Nfpa StandardsNFPA 72, National Fire Alarm and Signaling Code, like all N
13、FPA codes, standards, recommended practices, and guides (“NFPA Standards”), may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. An official NFPA Standard at any point in time consists of the current edition of the document together with any T
14、entative Interim Amendment and any Errata then in effect. In order to determine whether an NFPA Standard has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, visit the Document Information Pages on NFPAs website. The Document Information Pages provide up-to-d
15、ate, document specific information including any issued Tentative Interim Amendments and Errata. To access the Document Information Page for a specific NFPA Standard go to http:/www.nfpa.org/document for a list of NFPA Standards, and click on the appropriate Standard number (e.g., NFPA 72). In addit
16、ion to posting all existing Tentative Interim Amendments and Errata, the Document Information Page also includes the option to sign-up for an “Alert” feature to receive an email notification when new updates and other information are posted regarding the document.The following are registered tradema
17、rks of the National Fire Protection Association: National Fire Protection AssociationNFPANFPA 72Building Construction and Safety Codeand NFPA 5000Fire Protection HandbookLife Safety Codeand 101National Electrical Code, NEC, and NFPA 70NFPA No.: 72HB16ISBN (book): 978-145590-9360ISBN (PDF): 978-14559
18、0-9377ISBN (e-book): 978-145591-2872Library of Congress Control No.: 2015943729Printed in the United States of America15 16 17 18 19 5 4 3 2 1BK-NFPA-72HB16-150223-FM.indd 4 9/14/2015 8:16:34 PMDedicationThe editors of the National Fire Alarm and Signaling Code Handbook, Eighth Edition, proudly dedi
19、cate this edition to Lee Richardson, editor of the Fourth, Fifth, Sixth, and Seventh editions of the handbook. Lee was senior electrical engineer at NFPA and a longtime NFPA employee. He retired in 2015 after many years as staff liai-son of NFPA 72, National Fire Alarm and Signaling Code, and NFPA 7
20、20, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment. Lee was tenacious, detailed, and dedicated to fire alarm safety. He was also strongly committed to the codes and standards consensus development process by which the National Fire Alarm and Signaling Code is d
21、eveloped. Over the years, Lee worked with many Technical Committees and Task Groups and served on several industry committees and panels. He also served as staff liaison for many other NFPA documents, including NFPA 85, NFPA 86, NFPA 86C, and NFPA 86D.Lee will be greatly missed at NFPA, and we wish
22、him well in his retirement.BK-NFPA-72HB16-150223-FM.indd 5 9/14/2015 8:16:38 PMBK-NFPA-72HB16-150223-FM.indd 6 9/14/2015 8:16:38 PMviiContentsPreface xiAcknowledgments xiii About the Contributors xvAbout the Editors xixPART ONENFPA 72, National Fire Alarm and Signaling Code, 2016 Edition, with Comme
23、ntary 11 Administration 31.1 Scope 31.2 Purpose 51.3 Application 71.4 Retroactivity 111.5 Equivalency 121.6 Units and Formulas 121.7 Code Adoption Requirements 132 Referenced Publications 152.1 General 152.2 NFPA Publications 152.3 Other Publications 162.4 References for Extracts in Mandatory Sectio
24、ns 173 Definitions3.1 General 193.2 NFPA Official Definitions 193.3 General Definitions 214 Reserved 935 Reserved 936 Reserved 937 Documentation 957.1 Application. (SIG-FUN) 957.2 Minimum Required Documentation. (SIG-FUN) 967.3 Design (Layout) Documentation 997.4 Shop Drawings (Installation Document
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA72H2016NATIONALFIREALARMANDSIGNALINGCODEHANDBOOKEIGHTTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1008809.html