NEMA MG 10-2013 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors.pdf
《NEMA MG 10-2013 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors.pdf》由会员分享,可在线阅读,更多相关《NEMA MG 10-2013 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、 NEMA MG 10-2013 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors NEMA MG 10-2013 Energy Management Guide For Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors Published by National Electrical Ma
2、nufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, Virginia 22209 www.nema.org 2014 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Lit
3、erary and Artistic Works, and the International and Pan American copyright conventions. NOTICE AND DISCLAIMER The information in this publication was considered technically sound by a consensus among persons engaged in its development at the time it was approved. Consensus does not necessarily mean
4、there was unanimous agreement among every person participating in the development process. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document herein is one, are developed through a voluntary standards development process. This process
5、 brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. Although NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the documents, nor does it independently
6、 test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature, whether special, indirect, consequential, or
7、 compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty t
8、hat the information in this document will fulfill any particular purpose(s) or need(s). NEMA does not undertake to guarantee the performance of any individual manufacturers or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is
9、not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advi
10、ce of a competent professional in determining the exercise of reasonable care in any given circumstance. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by
11、 this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any healt
12、h- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. MG 10-2013 Page i 2014 National Electrical Manufacturers Association CONTENTS Foreword . ii Scope ii Section 1 INTRODUCTION . 1 1.1 Referen
13、ced Standards . 1 1.2 General 3 1.2.1 Medium Motors 3 1.2.2 Usual Service Conditions 3 1.3 Power Supply. 3 1.3.1 Ratings 3 1.3.2 Effects of Variation in Voltage and Frequency 4 1.3.3 Effects of Voltage Unbalance 4 1.4 Efficiency . 4 1.4.1 Motor Losses . 8 1.4.2 Variations in Motor Losses 8 1.4.3 Eff
14、iciency Testing Methods . 9 1.4.4 Testing Variations . 9 1.4.5 Manufacturing Variations 9 1.4.6 NEMA Standards on Efficiency Nomenclature and Labeling 9 1.5 Evaluation of Efficiency Economics . 13 1.5.1 Simple Payback Analysis 13 1.5.2 Present Worth Life Cycle Analysis 13 1.6 Motor Selection 15 1.6.
15、1 Induction Motors 15 1.6.2 Multispeed Motors . 15 1.7 Power Factor . 16 1.8 Application Analysis . 18 1.8.1 Applications Involving Load Cycling 18 1.8.2 Applications Involving Extended Periods of Light Load Operation . 21 1.8.3 Applications Involving Throttling or Bypass Control 21 1.8.4 Applicatio
16、ns Involving Overhauling Loads 23 Section 2 MAINTENANCE 24 MG 10-2013 Page ii 2014 National Electrical Manufacturers Association Foreword The Motor and Generator Section of NEMA published the first edition of MG 10 with the statement to periodically review the guide for the purpose of keeping it up
17、to date with advancing technology. This edition, MG 10-2013 is the result of this commitment to include typical characteristics of IEC Design H and N induction motors and information on the NEMA energy efficient and Premium efficiency motor standards. The goal of this guide is to assist the reader i
18、n the choice of equipment for his application. The practice of periodically reviewing and updating the guide will be continued. Comments on the guide from readers are welcomed and should be addressed to: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 North 1
19、7th Street, Suite 900 Rosslyn, Virginia 22209 Scope This energy management guide provides practical information concerning the proper selection and application of medium AC polyphase squirrel-cage induction motors including installation, operation, and maintenance in fixed frequency applications MG
20、10-2013 Page 1 2014 National Electrical Manufacturers Association Section 1 INTRODUCTION The shortage and large cost increases of vital national energy resources has demonstrated the need to conserve such resources. In 1992 the Energy Policy Act mandated minimum levels of nominal efficiency which so
21、me classes of motors were required to meet after October 27, 1997. As a result of the market demand for standardization in the identification of motors having efficiency that exceeded the levels set by the Energy Policy Act, NEMA introduced the new Premium efficiency motor standard in June of 2001.
22、In 2007 the U.S. Congress passed the Energy Independence and Security Act increasing the level of the efficiency standards on existing covered electric motors and added efficiency standards for additional types of electric motors manufactured on or after December 19, 2010. In February of 2011 NEMA r
23、evised Premium Efficiency Motor tables for medium motors by adding efficiency values for 8 pole Premium efficiency motors. It is important that motor users and specifiers understand the selection, application, and maintenance of electric motors in order to improve the management of electrical energy
24、 consumption. Energy Management as related to electric motors is the consideration of the factors that contribute to reducing the energy consumption of a total electric motor-driven system. Among the factors to be considered are the motor design and application. An electric motor is an energy conver
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAMG102013ENERGYMANAGEMENTGUIDEFORSELECTIONANDUSEOFFIXEDFREQUENCYMEDIUMACSQUIRRELCAGEPOLYPHASEINDUCTIONMOTORSPDF

链接地址:http://www.mydoc123.com/p-994305.html