NAVY UFGS-43 15 00 00 20-2006 LOW PRESSURE COMPRESSED AIR PIPING (NON-BREATHING AIR TYPE)《低压压缩空气管道(非呼吸用空气型)(代替 NAVY UFGS-15211N 08 01 03 NAVY UFGS-15211N)》.pdf
《NAVY UFGS-43 15 00 00 20-2006 LOW PRESSURE COMPRESSED AIR PIPING (NON-BREATHING AIR TYPE)《低压压缩空气管道(非呼吸用空气型)(代替 NAVY UFGS-15211N 08 01 03 NAVY UFGS-15211N)》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-43 15 00 00 20-2006 LOW PRESSURE COMPRESSED AIR PIPING (NON-BREATHING AIR TYPE)《低压压缩空气管道(非呼吸用空气型)(代替 NAVY UFGS-15211N 08 01 03 NAVY UFGS-15211N)》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-43 15 00.00 20 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-15211N (August 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION TABLE OF CONTENTSDI
2、VISION 43 - PROCESS GAS AND LIQUID HANDLING, PURIFICATION, AND STORAGEEQUIPMENTSECTION 43 15 00.00 20LOW PRESSURE COMPRESSED AIR PIPING (NON-BREATHING AIR TYPE)04/06PART 1 GENERAL1.1 REFERENCES1.2 RELATED REQUIREMENTS1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Welding procedures and qualifications1.4.1
3、.1 Butt Welded Joints1.4.2 Employers Record Documents1.4.3 Welding Procedures and Qualifications1.4.3.1 Certification1.4.3.2 Renewal of Qualification1.4.4 Equipment Data1.5 SAFETY PRECAUTIONS1.5.1 Temperature Restriction1.5.2 Rotating Equipment1.5.3 Welding and BrazingPART 2 PRODUCTS2.1 LOW PRESSURE
4、 AIR COMPRESSOR, 7 1/2 TO 224 KW 10 TO 300 HP2.2 LOW PRESSURE AIR COMPRESSOR UNIT, LESS THAN 7 1/2 kW 10 HP2.2.1 Compressor and Receiver Capacity2.2.2 Mounting2.2.3 Compressor Type2.2.4 Nameplate2.2.5 Receiver2.2.6 Receiver Condensate Drain2.2.7 Compressor Accessories2.2.8 Control2.2.9 Motor2.2.10 S
5、tarter2.2.11 NoiseSECTION 43 15 00.00 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.3 LOW PRESSURE AIR RECEIVER2.4 LOW PRESSURE COMPRESSED AIR DRYERS2.4.1 Air Circuit2.4.2 Refrigeration System2.4.3 Instrumentation and Control2.5 LOW PRES
6、SURE COMPRESSED AIR DRYER (CHILLED WATER TYPE)2.5.1 Air Circuit2.5.2 Chilled Water Circuit2.5.3 Refrigeration System2.5.4 Instrumentation and Control2.5.5 Temperature Indicators2.6 DESICCANT AIR DRYERS2.7 LOW PRESSURE COMPRESSED AIR PIPING AND ACCESSORIES2.7.1 Steel Piping2.7.2 Copper Tubing2.7.3 Va
7、lves2.7.3.1 Gate Valves2.7.3.2 Globe and Angle Valves2.7.3.3 Pressure Reducing Valves2.7.3.4 Safety Valves2.7.3.5 Check Valves2.7.3.6 Pressure Regulators2.7.3.7 Needle Valves2.7.3.8 Ball Valves2.7.4 Pressure Gages2.7.5 Hangers and Supports2.7.6 Quick Disconnect Couplings2.7.7 Single Cartridge Type F
8、ilters2.7.8 Strainers2.7.9 Traps2.7.10 Lubricators2.7.11 Flexible Connections2.7.12 Dielectric Unions2.7.13 Tetrafluoroethylene Tape2.7.14 Hose Reel Assembly2.8 SLEEVES2.8.1 Floor Slabs, Roof Slabs, and Outside Walls Above and Below Grade2.8.2 Partitions2.9 VALVE BOX2.10 IDENTIFICATION LABELS FOR PI
9、PING2.11 BURIED UTILITY WARNING AND IDENTIFICATION TAPE2.12 FRESH WATER2.13 SOURCE QUALITY CONTROLPART 3 EXECUTION3.1 INSTALLATION3.1.1 Excavation and Backfilling3.1.2 Corrosion Protection3.1.3 Piping3.1.3.1 Fittings3.1.3.2 Clearances for Welding3.1.3.3 Cleaning and Flushing Procedures3.1.3.4 Change
10、s in Pipe Size3.1.3.5 Drainage and Flexibility3.1.4 Threaded Joints3.1.5 Welding and Brazing Procedures3.1.5.1 Cleaning for Welding and Brazing3.1.5.2 Stress Cracking During BrazingSECTION 43 15 00.00 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
11、IHS-,-,-3.1.5.3 Welding or Brazing of Valves3.1.6 Flare Fittings3.1.7 Valves3.1.7.1 Gate Valves3.1.7.2 Globe Valves3.1.7.3 Pressure-Reducing Valves3.1.8 Hangers and Supports3.1.9 Pressure Gages3.1.10 Strainers3.1.11 Equipment Foundations3.1.12 Equipment Installation3.1.13 Cleaning of System3.1.14 Pi
12、pe Sleeves3.1.15 Floor, Wall, and Ceiling Plates3.1.16 Flashing for Buildings3.1.17 Unions and Flanges3.1.18 Painting of Piping and Equipment3.1.19 Identification of Piping3.1.20 Warning and Identification Tape3.2 CLEANING SILVERBRAZED PIPING3.2.1 Hot Flushing Method3.2.2 Hot Recirculating Flush Met
13、hod3.2.3 Cold Soak Method3.3 FIELD QUALITY CONTROL3.3.1 Examinations3.3.1.1 Welding Examinations3.3.1.2 Brazing Examinations3.3.2 Testing3.3.2.1 General Requirements, Testing3.3.2.2 Hydrostatic Tests and Leak Tightness Tests3.3.2.3 Operational Tests3.4 INSTRUCTION TO GOVERNMENT PERSONNEL- End of Sec
14、tion Table of Contents -SECTION 43 15 00.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-43 15 00.00 20 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-15211N (August 2003)UNIFIED
15、 FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION 43 15 00.00 20LOW PRESSURE COMPRESSED AIR PIPING (NON-BREATHING AIR TYPE)04/06*NOTE: This guide specification covers the requirements for non-breathing air compressed a
16、ir systems inside of buildings with pressures up to 862 kPa (gage) 125 psig.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telepho
17、ne number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).Use of electronic communication is encouraged.Brackets are used in the text to indicate designer choices or locations where text must be supplied by the designer.*NOTE: Project requirem
18、ents may require supplemental information added to the paragraphs contained herein.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in th
19、is paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature SECTION 43 15 00.00 20 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-when you add a RID outside of the Sections Reference Article to
20、automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the pub
21、lish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AIR-CONDITIONING AND REFRIGERATION INSTITUTE (ARI)ARI 520 (2004) Positive Displacement Condensing UnitsAMERICAN
22、 NATIONAL STANDARDS INSTITUTE (ANSI)ANSI B16.24 (1991; Errata 1991) Cast Copper Alloy Pipe Flanges and Flanged Fittings Class 150, 300, 400, 600, 900, 1500, and 2500AMERICAN WELDING SOCIETY (AWS)AWS D1.1/D1.1M (2006) Structural Welding Code - SteelAWS Z49.1 (1999) Safety in Welding, Cutting and Alli
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS43150000202006LOWPRESSURECOMPRESSEDAIRPIPINGNONBREATHINGAIRTYPE 低压 压缩空气 管道 呼吸 空气 代替 NAVYUFGS15211N080103NAVYUFGS15211NPDF

链接地址:http://www.mydoc123.com/p-984873.html