NAVY MIL-S-15103 F INT AMD 3-2006 SALINITY INDICATING EQUIPMENT《盐度显示设备》.pdf
《NAVY MIL-S-15103 F INT AMD 3-2006 SALINITY INDICATING EQUIPMENT《盐度显示设备》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-S-15103 F INT AMD 3-2006 SALINITY INDICATING EQUIPMENT《盐度显示设备》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandardsnavy.mil, with the subject line “Document Comment”. Since contact
2、information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 6630 INCH-POUND MIL-S-15103F(SH) w/INT. AMENDMENT 3 6 June 2006 USED IN LIEU OF MIL-S-15103F(SH) w/AMENDMENT 2 13 July 2000 MILITARY SPE
3、CIFICATION SALINITY INDICATING EQUIPMENT This specification is approved for use within the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers salinity indicating equip
4、ment consisting of multi-channel consoles and sensors. Multi-channel consoles provide for individual salinity channel modules, individual visual alarms, a common meter, and a common audible alarm. These consoles have the ability to actuate externally-operated dump valves, indicators, and alarms. Con
5、soles employ temperature compensated salinity sensors. 1.2 Console type designation. The console type designation shall be in the following form as specified (see 6.2.1): IC/SB 15 B 3D 005M 8 Equipment (see 1.2.1) Salinity channel module capacity (see 1.2.2) Console type (see 1.2.3) Dump valve circu
6、its (see 1.2.4) Maximum indication and scale units (see 1.2.5) Salinity modules provided (see 1.2.6) 1.2.1 Equipment. The equipment shall be identified by the four-letter symbol “IC/SB” which denotes that the equipment is part of the interior communication (IC) system, salinity indicating circuit (S
7、B). 1.2.2 Salinity channel module capacity. A number denotes the maximum number of salinity channel modules that can be accommodated by the console. Consoles shall be available in capacities of 1, 7, and 15 channels for the basic console and 7 and 15 channels for the repeater console. 1.2.3 Console
8、type. A single letter denotes the console type as follows: B - Basic console. R - Repeater console (see 3.10.1). M - Dual meter console (see 3.10.2). 1.2.4 Dump valve circuits. This designation, consisting of one digit and the letter D, denotes the number of dump valve control circuits provided. The
9、 possible designations are 3D, 2D, 1D, and 0D (0D signifying that there is no dump capability provided). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-S-15103F(SH) 1.2.5 Maximum indication and scale units. This designation, as shown below, deno
10、tes the maximum range of the transmitter or meter readout and the scale units. Scale units are indicated by M (microsiemens per centimeter (S/cm) and P (parts per million (p/m) of chloride). Standard ranges shall be as follows: 005M 0 to 5 S/cm 050M 0 to 50 S/cm 010P 0 to 10 p/m of chloride 050P 0 t
11、o 50 p/m of chloride 02500M 0 to 2500 S/cm 005M/050M Dual meter console; 0 to 5 S/cm and 0 to 50 S/cm Meters for applications requiring other than the standard meter scales shall be approved by NAVSEA. An “S” following the scale unit designation shall indicate a special meter requirement. 1.2.6 Sali
12、nity modules provided. This number denotes the actual number of salinity channel modules provided. 1.2.7 Special console requirements. An “S” following the number of salinity modules provided shall indicate a special console requirement. 1.3 Salinity sensor type designation. The salinity sensor type
13、 designation shall be in the following form: IC/SB 1 10 Identification (see 1.3.1) Material (see 1.3.2) Sensor constant (see 1.3.3) 1.3.1 Identification. The salinity sensor shall be identified by the four letters “IC/SB” denoting interior communication salinity indicating circuits. 1.3.2 Material d
14、esignation. This designation shall indicate the material of the sensor as follows: 1 - Brass. 2 - Corrosion-resistant steel. 1.3.3 Sensor constant. This designation shall indicate the sensor constant as follows: No designation - 0.1/cm 5 - 5.0/cm10 - 10.0/cm 2. APPLICABLE DOCUMENTS 2.1 Government Do
15、cuments. 2.1.1 Specifications and Standards. The following specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications
16、and Standards (DoDISS) and supplement thereto, cited in the solicitation. SPECIFICATIONS FEDERAL PPP-F-320 - Fiberboard; Corrugated and Solid, Sheet Stock (Container Grade), and Cut Shapes. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-S-1510
17、3F(SH) MILITARY MIL-S-901 - Shock Tests, H.I. (High-Impact); Shipboard Machinery, Equipment and Systems, Requirements for. MIL-R-5757 - Relays, Electromagnetic, General Specification for. MIL-M-10304 - Meters, Electrical Indicating, Panel Type, Ruggedized, General Specification for. MIL-M-10304/23 -
18、 Meters, Electrical Indicating, Panel Type, Ruggedized: Voltmeter and Ammeter, DC, Long Scale (Flush Mounting, Round Flange, 4-1/2 Inch), Style 44. MIL-P-15024 - Plates, Tags and Bands for Identification of Equipment. MIL-P-15024/5 - Plates, Identification. MIL-A-15303 - Audible Signals: Alarms, Bel
19、ls, Buzzers, Horns, and Sirens, Electronic, Shipboard. MIL-V-16556 - Valve, Solenoid, Three-Way Bypass (Naval Shipboard Use). MIL-C-24643 - Cable and Cord, Electrical, Low Smoke, For Shipboard Use, General Specification For. MIL-C-24643/2 Cable, Electrical, 300 Volts, Types LSDCOP and LSTCOP. MIL-E-
20、17555 - Electronic and Electrical Equipment, Accessories, and Provisioned Items (Repair Parts): Packaging of. MIL-L-19140 - Lumber and Plywood, Fire Retardant Treated. MIL-S-19500 - Semiconductor Devices, General Specification for. MIL-R-19523 - Relays, Control, Naval Shipboard. MIL-P-24423 - Propul
21、sion and Auxiliary Control Consoles and Associated Control and Instrumentation Equipment, Naval Shipboard Use, Basic Design Requirements. MIL-R-39016 - Relays, Electromagnetic, Established Reliability, General Specification for. MIL-T-46072 - Tube, Round, Copper Alloy Numbers 330, 331, 332 and 370 (
22、Leaded Brass), Seamless. STANDARDS MILITARY MIL-STD-108 - Definitions of and Basic Requirements for Enclosures for Electric and Electronic Equipment. MIL-STD-167-1 - Mechanical Vibrations of Shipboard Equipment (Type I Environmental and Type II Internally Excited). MIL-STD-454 - Standard General Req
23、uirements for Electronic Equipment. MIL-STD-461 - Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference. MIL-STD-462 - Electromagnetic Interference Characteristics, Measurement of. 3 Provided by IHSNot for ResaleNo reproduction or networking permitt
24、ed without license from IHS-,-,-MIL-S-15103F(SH) MILTARY (Continued) MIL-STD-701 - Lists of Standard Semiconductor Devices. DOD-STD-1399, Section 300 - Interface Standard for Shipboard Systems Electric Power, Alternating Current. (Metric) 2.1.2 Other Government drawings. The following other Governme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILS15103FINTAMD32006SALINITYINDICATINGEQUIPMENT 盐度 显示 设备 PDF

链接地址:http://www.mydoc123.com/p-981485.html