NAVY MIL-R-24037 A-1969 RADIACMETERS QUARTZ-FIBER SELF-INDICATING GENERAL SPECIFICATION《石英光纤自我显示通用规范放射性检测》.pdf
《NAVY MIL-R-24037 A-1969 RADIACMETERS QUARTZ-FIBER SELF-INDICATING GENERAL SPECIFICATION《石英光纤自我显示通用规范放射性检测》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-R-24037 A-1969 RADIACMETERS QUARTZ-FIBER SELF-INDICATING GENERAL SPECIFICATION《石英光纤自我显示通用规范放射性检测》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-R-24037A bb I 7777906 O423322 5 W MIL-R- 2403 7A 12 December 1969 SUPERSEDING MIL-R-24037(SHIPS) 29 May 1964 and 25 Sanuary 1954 MIL-R-10059D MILITARY SPECIFICATION RADIACMETERS, QUARTZ-FIBER SELF- INDICATING GENERAL SPECIFICATION This specification is mandatory for use by ali Departments and Ag
2、encies of the Department of Defense. 1. SCOPE 1.1 This specification covers ion-chamber quartz-fiber dosimeters (radiacmeters) capable of measuring doses of gamma or X-radiation. 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids or request for
3、proposal, form a part of this specification to the extent specified herein: SPECIFICATIONS FEDERAL PPP-B-566 - Boxes, Folding, Paperboard PPP-B-636 - Box, Fiberboard PPP-B-676 - Boxes, Setup PPP-T-76 - Tape, Pressure-Sensitive Adhesive Paper, Water Resistant, for Carton Sealing PPP-T-97 - Tape, Pres
4、sure-Sensitive Adhesive, Filament Reinforced MIL-P-116 - Preservation, Methods of MIL-A-8625 - Anodic Coatings, or Aluminum and Aluminum Alloys MIL-P- 15024 - Plates, Identification - Information and Marking for Identification of Electrical, MIL-E-21981 - Electronics Type Designation, Identification
5、 Plates and Markings; Requirements MIL-C-23237 - Charger, Radiac Detector MIL-1-45208 - Inspection System Requirements MIL-C-55038 - Charger, Radiac Detector PP-1578(. )/PD MILITARY Electronic and Mechanical Equipment for STANDARDS MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection
6、 by Attributes MIL-STD-129 - Marking for Shipment and Storage MIL-STD-167 - Mechanical Vibrations of Shipboard Equipment MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts MIL-STD-454 - Standard General Requirements for Electronic Equipment (Copies of specifications, standards,
7、 drawings, and publications required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contract- ing officer.) FSC 6665 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
8、 MIL-R-24037A bb 777770b ._ 0423323 7 R!l MIL-R -24037A 2.2 Other publications. - The following document f0rms.a part of this specification to the extent specified herein, Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply: OFFICUL CLAS
9、SIFICATION COMMITTEE Uniform Freight Classification Rules (Application for copies should be addressed to the Official Classification Committee, Room 202 Union Station, 516 West Jackson Boulevard, Chicago, Illinois 60606.) 3. REQUIREMENTS 3.1 Qualification. - quartz fiber dosimeters furnished under t
10、his specification shall be a product which has been tested and passed the qualification tests specified herein, and has been listed on or approved for listing on the applicable qualified products list (see 6.2). 3.2 Detail requirements for individual quartz-fiber dosimeters. - Detail requirements or
11、 exceptions applicable to individual types of quartz-fiber dosimeters shall be as specified in the detail specifications listed in Supplement 1 to this specification. In the event of any conflict between requirements of this specification and the detail specification, the latter shall govern. 3.3 Re
12、quirements to be included in detail specifications. 2 The following requirements shall be as spec- (a) Scale marking. (b) Range. (C) Leakage and leakage after heavy irradiation. (d) Accuracy, (e) Energy dependence. (f) Ion chamber saturation and rate dependence. 3.4 Reliability. - The equipment will
13、 be subjected to continuous use for long periods under the varied ified in the detail specifications: and severe conditions of Military service without overhaul. If it is to meet these conditions, it is imperative that reliability of operation be considered of prime importance in the design and manu
14、facture of the equip- ment. The manufacturer shall employ ali methods possible in the process of manufacture which will ascfure quality and maximum reliability parts to equipment circuits, adequate factors of safety shall be provided by suitable deratings from the part specification values in order
15、to insure high equipment reliability under all service conditions, The design shall include all possible features which will result in reliable and stable operation. 3.5 Materials. - Materials shall be chosen with care, not only from a standpoint of complete suitability (a) Minimal response to neutr
16、ons. (b) Minimum use of materials with appreciable neutron cross-sections wherever possible. (c) Proper energy dependence as specified in the individual detail specification. for the purpose intended, but also based on the following three considerations: 3.6 Description. - The radiacmeter shall be a
17、 hermetically-sealed, pocket-type quartz-fiber electroscope for detecting and indicating integrated exposures to X- and gamma radiations. The electroscope shall dis- charge by an amount proportional to the quantity of radiation which passes through the chamber. The total amount of radiation to which
18、 the instrument has been exposed shall be indicated by the image of the electro- scope fiber on a calibrated reticle. It shall be possible to observe the position of the fiber image on the reticle when the radiacmeter is pointed at a source of light. The instrument shall have a cylindrical barrel eq
19、uipped with an alligator type pocket clip. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-24037A bb W 777770b 0423324 9 W I MIL-R-24037A 3.7 Mechanical. - 3.7.1 Electroscope fiber. - The electroscope fiber shaU be constructed of quartz or an
20、y equivalent ma- terial approved by the command or agency concerned, 3.7.2 a. - we reticle shall be etched or engraved. or applied by the glue silver process or any other process approved by the command or agency concerned on a diaphragm of glass or other material satisfactory to the command or agen
21、cy concerned. The scale shall be unaffected by strong sunlight or the range or storage temperatures specified in 3.10. 3.7.2.1 Imperfections or spots. - Imperfections or spots, on the scale (a) shall not be wider than the width of a major scale line in the rectangular area defined by the scale gradu
22、ations, (b) spots external to this area may be of such size and number so that the integrated total area of these spots shall appear no greater than the area of the zero mark on the scale. For this purpose only those spots having a diameter larger than the width of a major division Line shall be cou
23、nted. 3.7.2.2 Scale division spacing. - Using the zero and central readings as a datum, scale division spacings shall not deviate more than 5 percent at the 1/4 and 3/4 scale levels and not more than 10 percent at the full scale level, 3.7.3 Charging electrode diaphragm. - The charghg electrode diap
24、hragm shall be constructed of a flexible, high ohmic resistant material. The charging electrode shall be mounted in the center of the dia- phragm. The diaphragm shall be so constructed that theforce required, at sea level and at an ambient tem- perature of 70 ISOF., on the charging electrode to make
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR24037A1969RADIACMETERSQUARTZFIBERSELFINDICATINGGENERALSPECIFICATION 石英 光纤 自我 显示 通用 规范 放射性 检测

链接地址:http://www.mydoc123.com/p-981199.html