NAVY MIL-P-22497C-1970 POWER SUPPLY TYPE IV(A) (TORPEDO TESTING).pdf
《NAVY MIL-P-22497C-1970 POWER SUPPLY TYPE IV(A) (TORPEDO TESTING).pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-P-22497C-1970 POWER SUPPLY TYPE IV(A) (TORPEDO TESTING).pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、MILITARY SPECIFICATION POWER SUPPLY, WE IV(A) .L (TORPEDO TESTING) . .1 .- -. _. . This specifica%ion has been approved by the Naval Ordnance Systems Command, Department of the Navy 1. SCOTE 1.1 Scope. This specification describes the requirements for the pro- curement of a rectifier type power supp
2、ly for use in Naval shipboard or er mppy Type IV(A) wi supply var- ical svstems normally energized by - .- shore-based torpedo workshops. Pow ious dc voltages for torpedo electr- - storage batteries. In ad$+ nn +.n mmnlvinE continuous direct current, . Contents of the manual shall be subject to the
3、approval of the procuring activity. 3.2.18 installation data. The contractor will provide the procuring activity with a reproducible copy of basic installation data vithin 90 days after receipt to the contract. This data shall give all informa- tion necessary for planning the installation of power s
4、upplies, such as . b Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-22497C( os) o-ierall size, weigh%, position and typ of input connector, power rating, t:l.pe O .;entilation, location of ventilation louvers, control Location, ani position of
5、 output connector. This data shall be shown on the con- zactor s drakrings. L 3.3 Zerformance requirements and product characteristics. The power sugply shall meet the following performance requirements and product Characteristics : 3.3.1 Input power source. The unit shall operate satisfactorily fro
6、m any one of the following power sources: 3.3.1.1 Input voltage. The power supply shall o2erate satisfactorily from +phase input voltages of either 208 plus or minus 10 percent, 220 plus or minus 10 percent, or 440 plus or minus 10 percent. 3.3.1.2 Input frequency. 50 or 60 Hz plus or minus 5 percen
7、t. 3.3.1.3 Input current. The input current to the power supply shall not exceed 25 amperes per phase when operated at the minimum specified input of 208 minus 10 percent volts while providing rated dc output.of 90 volts at 50 amperes. When operating with an inpu% of 440 minus 10 percent volts while
8、 providing rated dc output of 90 volts at 50 amperes, the input current to the power supply shall-not exceed 12 apeies per phse. 3.3.1.4 Phase sequence. The power supply shall operate as specified . without regard to the phase sequence of the input power. 3.3.2 Output voltages and current. The dc ou
9、tput of the power supply shall be available in two ranges, identified as the LOW range and HIGH range, which shall be selectable fromthe front panel by means of a two- position, rotary-type switch. The voltage and current requirements in both ranges are as follows: SFJITCH VOLTAGE RATED CONT. MAX. S
10、URGE CURRENT 33SITION RANGE CUflRrn (START TO 15 SECOND) Low 6 - 40 vdc 100 amperes 200 amperes BIGE 6 - 90 vdc 50 amperes 100 amperes 3.3.2.1 Static load regulation. With constant line voltage, the out- put voltage shall not vary more than plus or minus one percent with an- cutput current change fr
11、on no-load to continuous rated full load 7 Y-. I i- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_ MIL-P-22477C 13 7997706 O302463 T 3.3.2.2 Dynarn5.c repiLal;ion and response t-tme. In the LOW RANGE posi- tion with the sudden application or relea
12、se of any load current up to 50 aTperes, the voltage at the output terminals shall not fall nor rise more b,-.an 5 gercent fromthe no-load setting and shall decline to 37 percent of tke -,-oltage excursion within 75 milliskconds. plies ta any output-voltage above 25 volts. 25 clzs,. k4th the sudden
13、application or release of any load current up to 50 mperes, the voltage at the output terminals shall not fall nor rise more than 1.25 volts and shall recover to within 0.5 volt of the no- load voltage within 75 milliseconds. L. . This requirement ap- At no-load settings below 3.3.2.2.1 Overshoot or
14、 undershoot. A momentary interruption of the ac . input power shall not cause the output voltage to overshoot the preset value by more than 5 percent. When ac input power is applied to the power supply, the dc output voltage shall rise at a rate of not less than 30 volts per second to the voltage se
15、t by the output voltage con- trol. The output .voltage shall not overshoot the preset value by more than 5 percent, and shal1,retwn to the preset value in less than 0.5 second. A sudden change in the position of the output voltage control setting shall not cause an overshoot or an undershoot of volt
16、age in ex- cess of 5 percent of the new preset value. 3.3.2.3 Output stability. At any given voltage setting within the voltage range specified in 3.3.2, the output voltage shall remain with- in olus or minus one volt, without adjustment, for a minimum of four Oou_rs, monitored continuously by use o
17、f the voltmeter recorder of 4.5.5. 3.3.2.4 Static line regulation. The static line regulation shall not exceed 1 percent for a plus or minus 10 percent line voltage change or a plus or minus 5 percent variation of input frequency at constant ioad. 3.3.2.5 Output voltage control. Changes in the power
18、 supplys output voltage control shall result in simultaneous changes in the dc output voltage, with negligible lag. adjusting the output voltage in the range of 6 to 90 volts within in- crements of less than one-half volt. The output voltage shall be inear within plus or minus 20 degrees with respec
19、t to the angular displacement of the output voltage control. The voltage control shall be capable of 3.3.2.6 Ripple voltage. The ripple content of the dc output o9 the powsr sup-1)- shall not exceed 0.50 percent rms (1.50 percent peak-lo- geai:) cit. m;.- output aboire 25 volts or current within rat
20、ing in the LOW civa, va, rale. -. 3.3.2.7 Output isolation. Output of the powersupply shall be isolated from ground with either polarity capable of being grounded. 8 - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-22497C 13 m 9999906 030246
21、4 L II i- . . MIL-P-22497C( OS) 3.3.2.8 Loss-of-phase protection. Protection against damage to the pover supply due to the loss of any one of the 3-phse inputs shall be 2rovided. 3.3.2.9 Series operation. The power supply shall be so designed and ccnstructed that the outputs of two units may be conn
22、ected series-additive $0 obtain an output voltage equal to the sum of the output voltages of the Individual power supplies. except the series connection of output terminals shall be required. . For series operation, no interconnection NOTE Khen operating two power supplies with series-connected outp
23、ut circuits, tne output voltage controls shall be -varied simultaneously to approximately bal- ance the voltage and load between the two units 3.3.2.10 Current limiting. The power supply shall incorporake a con- tinuous current limiting circuit to limit the current to il5 amperes plus O minus i5 amp
24、eres in the HIGH voltage range, and 230 amperes plus O minus- 30 amperes in the LOWvoltage range, and shall automatically restore the output voltage to its original preset value upon removal of the overload. 3.3.2.11 The power supply shall operate as speciied herein for any coiiibincttion OC resisti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。