NAVY MIL-H-24776-1992 HYDRAZINE TEST KIT NAVAL SHIPBOARD (METRIC)《海军军舰上的肼测试装备(衡量标准)》.pdf
《NAVY MIL-H-24776-1992 HYDRAZINE TEST KIT NAVAL SHIPBOARD (METRIC)《海军军舰上的肼测试装备(衡量标准)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-H-24776-1992 HYDRAZINE TEST KIT NAVAL SHIPBOARD (METRIC)《海军军舰上的肼测试装备(衡量标准)》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-H-2477b 68 999990b 0575982 b MILITARY SPECIFICATION HYDRAZINE TEST KIT, NAVAL SHIPBOARD (METRIC) !METRIC I MIL-H-Z4776(SH) 8 June 1992 This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the
2、Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a water testing outfit using an organic dye for the determination of hydrazine in feedwater and boiler water. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifica
3、- tions, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the soli
4、citation (see 6.2). SPECIFICATIONS FEDERAL PPP-F-320 - Fiberboard, Corrugated and Solid, Sheer Stock (Con- tainer Grade) and Cut Shapes MILI TARY MIL-P-116 - Preservation, Methods of. MIL-L-19140 - Lumber and Plywood, Fire Retardant Treated STANDARDS FEDERAL FED-STD-313 - Material Safety Data, Trans
5、portation Data and Disposal Data for Hazardous Materials Furnished to Government Activities Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 5523, Depart
6、ment of the Navy, Washington, DC 20362-5101 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 6810 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHS
7、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-24776 68 m 777770b 0575783 8 m MIL I TARY MIL-STD-2073-1 - DOD Material Procedures for Development and Ap- plication of Packaging Requirements (Unless otherwise indicated, copies of federal and military specific
8、ations, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D 700 Robbins Avenue, Philadelphia, PA 19111-5094. 2.2 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified,
9、 the issues of the documents which are DOD adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR TESTING AND
10、 MATERIALS (ASTM) D 1385 - Standard Test Method for Hydrazine in Water. D 3951 - Standard Practice for Commercial Packaging. (DoD adopted) (Application for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) (Non-Government standar
11、ds and other publications are normally available from the organizations that prepare or distribute the documents. These documents also may be available in or through libraries or other informational services.) 2.3 Order of precedence. In the event of a conflict between the text of this document and
12、the references cited herein, (except for related associated detail specifications, specification sheets, or MS standards), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUI
13、REMENTS 3.1 Definition. The hydrazine test kit measures the amount of hydrazine present in feedwater and boiler water at both the parts per billion (p/b) and the parts per million (plm) level. The kit consists of a plastic sample with breaking device, evacuated ampoules containing test chemicals, an
14、d high and low range color comparators. 3.2 First article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 6.4) in accordance with 4.2.1. 3.3 Characteristics. 3.3.1 Performance. The hydrazine test kit shall measure the amount of hydrazine in feedwater and boile
15、r water between O and 500 p/b using the low range comparator and between O and 100 plm using the high-range conparator at a sample 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- e MIL-H-24776 68 9999906 0575984 T W MIL-H-Z4776(SH) I O temperature
16、 of 21 to 38 degrees Centigrade (OC). The value obtained shall be equal to the readable value nearest to the actual hydrazine level of the sample or to the next readable value above or below this value. Both comparators shall read O when no hydrazine is present. A readable value is defined as equal
17、to the value of a color standard, the average of two adjacent color standards, or greater than the highest color standard. 3.3.2 Physical characteristics. 3.3.2.1 Component parts. The hydrazine test kit shall consist of the following: (a) One low range colorimetric comparator. (b) One high range col
18、orimetric comparator. (c) One box of 30 ampoules. (d) One sample cup. (e) One storage case. 3.3.2.1.1 Low range colorimetric comparator. Details and dimensions of the low range color comparator used for making the hydrazine determinations shall be as shown on figure 1. The comparator shall consist o
19、f a transparent tube in which eight liquid filled, sealed glass standard color ampoules are mounted and enclosed. There shall be a center space into which the test ampoule can be inserted for color comparison. The comparator shall have the color standards representing O, 10, 30, 50, 70, 100, 300, an
20、d 500 p/b hydrazine. These color standards shall range in color from clear to light yellow to yellow. The standard color ampoules shall be fabricated to the same dimensions as the test ampoules, 3.3.2.1.3. The comparator shall be marked with the date of manufacture. The com- parator shall yield the
21、results as specified in table I when tested as specified in 4.5.1. TABLE I. Hydrazine solution values for low range comparator. Standard ( p/b hydrazine) Accepted values (P/b) O 10 30 50 70 1 O0 300 500 O 5, 10, 20 30 * 10.0 50 * 10.0 60, 70, 85 85, 100, 200 300 * 100 400, 500, greater than 500 3.3.
22、2.1.2 Hinh range colorimetric comparator. Details and dimensions of the high range color comparator used for making the hydrazine determinations shall be as shown on figure 2. The high range comparator shall consist of a rack in which nine liquid filled, sealed glass standard color ampoules are moun
23、ted. The comparator shall have the color standards representing O, 5, 10, 15, 20, 40, 60, 3 I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-24776 68 m 9999906 0575985 II P 80, and 100 p/m hydrazine. These color standards shall range in color
24、from clear to yellow to yellowish orange. the same dimensions as the test ampoules, 3.3.2.1.3. The comparator shall be marked with the date of the manufacture. The comparator shall yield the results as specified in table II when tested as specified in 4.5.1. The standard color ampoules shall be fabr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILH247761992HYDRAZINETESTKITNAVALSHIPBOARDMETRIC 海军 军舰 测试 装备 衡量 标准 PDF

链接地址:http://www.mydoc123.com/p-979492.html