NAVY MIL-DTL-24643 63 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LSYSGU《LSYSGU型1000 V电缆》.pdf
《NAVY MIL-DTL-24643 63 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LSYSGU《LSYSGU型1000 V电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 63 A-2010 CABLE ELECTRICAL 1000 VOLTS TYPE LSYSGU《LSYSGU型1000 V电缆》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/63A 28 January 2010 SUPERSEDING MIL-DTL-24643/63 1 March 2007 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, 1000 VOLTS, TYPE LSYSGU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the produc
2、t described herein shall consist of this specification sheet and MIL-DTL-24643. This cable type is specifically designed for single circuit (see figure 1), three-phase, wye connected (with neutral wire), 60 or 400 Hertz, electrical power distribution. The designation Y represents the wye connection.
3、 Using two conductors per phase reduces the series inductance to 50 percent of the single conductor per phase value. In addition, the symmetrical spacing of the phase conductors from the neutral wire provides for balanced voltage drop when three-phase loads are applied. Construction (Watertight with
4、 Circuit Integrity) First - Copper conductor, coated or uncoated (see table I for size). Second - Optional separator. Third - Extruded silicone rubber, or silicone rubber-glass tape insulation at the manufacturers option (see table I for diameter). Refer to table II for identification code. Fourth -
5、 Seven conductors cabled together with a left-hand lay of six conductors around the center conductor (see figure 2 for cross-sectional view). The length of lay shall not exceed 24 times the pitch diameter. Fillers may be employed to obtain a well-rounded assembly. Fifth - Optional binder. Sixth - Cr
6、oss-linked polyolefin jacket (see table I for thickness). AMSC N/A 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/63A TABLE I. LSYSGU sizes and characteristics. Conductor Cable Amps per Phase (2 conductors) Military part no. M2464
7、3/63 AWG Circular MILS Stranding 40 C ambient 50 C ambient /1000 ft 25 C (max.) Jacket thickness (min.) Overall diameter (max.) Weight (lbs/ft) -01UN 16 2580 7 x 0.0192 18 16 4.300 0.040 0.535 0.188 -02UN 14 4110 7 x 0.0242 29 27 2.680 0.040 0.580 0.255 -03UN 12 6530 7 x 0.0305 39 36 1.900 0.040 0.6
8、40 0.314 -04UN 10 10380 7 x 0.0385 62 58 1.125 0.040 0.730 0.420 -05UN 8 16510 19 x 0.0295 84 77 0.790 0.050 1.000 0.725 -06UN 4 41740 19 x 0.0469 145 133 0.287 0.050 1.170 1.400 -07UN 2 66360 19 x 0.0591 193 178 0.203 0.060 1.310 2.000 -08UN 1 83690 37 x 0.0476 237 218 0.145 0.060 1.450 2.400 -09UN
9、 0 105600 61 x 0.0416 272 254 0.120 0.060 1.600 3.000 -10UN 00 133100 61 x 0.0467 320 294 0.0888 0.065 1.780 3.750 -11UN 000 167800 61 x 0.0524 376 346 0.0674 0.065 1.880 4.500 NOTE: All dimensions are in inches unless otherwise specified. FIGURE 1. LSYSGU single circuit user diagram. 2 Provided by
10、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/63A 1 (A)6 (C)5 (B)4 (A)3 (C)2 (B)7 (N)FIGURE 2. LSYSGU cross-section design. TABLE II. LSYSGU identification code and color. Conductor # Identification code Color 1 A Black 2 B White 3 C Red 4 A Blac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464363A2010CABLEELECTRICAL1000VOLTSTYPELSYSGULSYSGU 1000 电缆 PDF

链接地址:http://www.mydoc123.com/p-978691.html