NAVY MIL-DTL-24640 23 E-2011 CABLE ELECTRIC -20 TO +105 癈 600 VOLTS LIGHTWEIGHT MULTI-CONDUCTOR 18 AWG TYPE MXCW (INCLUDING VARIATION TYPE MXCOW)《MXCW型18 AWG多芯轻量600V -20 ℃~+105 ℃电缆(包括变化型MXOW)》.pdf
《NAVY MIL-DTL-24640 23 E-2011 CABLE ELECTRIC -20 TO +105 癈 600 VOLTS LIGHTWEIGHT MULTI-CONDUCTOR 18 AWG TYPE MXCW (INCLUDING VARIATION TYPE MXCOW)《MXCW型18 AWG多芯轻量600V -20 ℃~+105 ℃电缆(包括变化型MXOW)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24640 23 E-2011 CABLE ELECTRIC -20 TO +105 癈 600 VOLTS LIGHTWEIGHT MULTI-CONDUCTOR 18 AWG TYPE MXCW (INCLUDING VARIATION TYPE MXCOW)《MXCW型18 AWG多芯轻量600V -20 ℃~+105 ℃电缆(包括变化型MXOW)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 6145 INCH-POUND MIL-DTL-24640/23E 8 November 2011 SUPERSEDING MIL-DTL-24640/23D 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRIC, -20 TO +105 C, 600 VOLTS, LIGHTWEIGHT, MULTI-CONDUCTOR, 18 AWG, TYPE MXCW (INCLUDING VARIATION TYPE MXCOW) This specification is approved for use by
2、 all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24640. Construction (Watertight) First - Copper conductor, coated or uncoated 18 AWG, 7 strands, in accordance with ASTM B8. S
3、econd - Mica glass tape insulation 0.00290.0002 inch (50 percent overlap maximum and minimum overlap of 45 percent). Conformance testing shall be in accordance with MIL-DTL-81381 prior to cabling. Third - Opaque-pigmented polyimide tape 0.001 inch (50 percent overlap minimum). Fourth - Opaque-pigmen
4、ted polyimide tape 0.001 inch with 0.0001 inch Fluorinated Ethylene Propylene (FEP) (50 percent overlap minimum). Fifth - Modified aromatic polyimide resin coating 0.0005 inch minimum (0.001 inch nominal). Identification codes applied using Method 1 or 3. Sixth - The required number of component wir
5、es shall be cabled together. Cabling sequence shall be consecutive, starting with number 1 from center outward. Fillers may be used, as necessary, to form a round cable. Seventh - Optional binder tape. Construction Variant for Type MXCW Eighth - Cross-linked polyolefin jacket (see table I for thickn
6、ess). NOTE: Manufacturers identification tape or thread is required (see 3.7.3). Construction Variant for Type MXCOW Eighth - Braided shield, tin-coated copper strands. Braid must be constructed to meet surface transfer impedance requirements as listed herein. Ninth - Optional binder tape. Tenth - C
7、ross-linked polyolefin jacket (see table II for thickness). NOTE: Manufacturers identification tape or thread is required (see 3.7.3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24640/23E 2 TABLE I. Construction details. PIN M24640/23 Ty
8、pe number Number of conductors Jacket thickness (inch) (min.) Cable diameter (inch) Cable weight (pounds per 1000 feet) (max.) (min.) (max.) -01UN -02UN -03UN -04UN -05UN -06UN -07UN -08UN -09UN MXCW-7 MXCW-10 MXCW-14 MXCW-19 MXCW-24 MXCW-30 MXCW-37 MXCW-44 MXCW-61 7 10 14 19 24 30 37 44 61 0.038 0.
9、041 0.041 0.041 0.044 0.044 0.044 0.044 0.047 0.295 0.375 0.402 0.440 0.520 0.547 0.584 0.656 0.729 0.319 0.405 0.434 0.474 0.560 0.589 0.630 0.708 0.785 90.0 139.0 173.0 215.0 295.0 340.0 398.0 492.0 640.0 TABLE II. Construction details - overall shield. PIN M24640/23 Type number Number of conducto
10、rs Jacket thickness (inch) (min.) Cable diameter (inch) Cable weight (pounds per 1000 feet) (max.) (min.) (max.) -01UO -02UO -03UO -04UO -05UO -06UO -07UO -08UO -09UO MXCOW-7 MXCOW-10 MXCOW-14 MXCOW-19 MXCOW-24 MXCOW-30 MXCOW-37 MXCOW-44 MXCOW-61 7 10 14 19 24 30 37 44 61 0.038 0.041 0.041 0.041 0.0
11、44 0.044 0.044 0.047 0.047 0.340 0.415 0.440 0.477 0.557 0.584 0.622 0.697 0.757 0.366 0.447 0.474 0.515 0.601 0.630 0.670 0.751 0.817 140.0 185.0 225.0 280.0 362.0 399.0 466.0 574.0 715.0 REQUIREMENTS: Qualification required. Construction details: See tables I and II. Finished wire: For polyimide t
12、ape constructions, the following additional tests shall be applicable in accordance with MIL-DTL-81381. Temperature rating 150 C (302 F) (max.) conductor temperature Voltage rating 600 volts (root mean square) at sea level Blocking Oven temperature, 1502 C (3023.6 F) no sticking of conductors Flamma
13、bility 3 seconds (max.) after flame 3.0 inches (max.) flame travel No flaming of tissue paper Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24640/23E 3 Humidity resistance 5 megohms for 1000 feet (min.) insulation resistance after humidity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464023E2011CABLEELECTRIC20TO105 600 VOLTSLIGHTWEIGHTMULTICONDUCTOR18AWGTYPEMXCWINCLUDINGVARIATIONTYPEMXCOWMXCW

链接地址:http://www.mydoc123.com/p-978622.html