MSS SP-105A-2016 Instrument Valves for Code Applications.pdf
《MSS SP-105A-2016 Instrument Valves for Code Applications.pdf》由会员分享,可在线阅读,更多相关《MSS SP-105A-2016 Instrument Valves for Code Applications.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、MSS SP-105-2016a Instrument Valves for Code Applications Standard Practice Developed and Approved by the Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. 127 Park Street, NE Vienna, Virginia 22180-4602 Phone: (703) 281-6613 Fax: (703) 281-6671 E-mail: standardsmsshq.org
2、 www.msshq.org NOTICE: This 2016a Edition Replaces the Original 2016 Edition. MSS STANDARD PRACTICE SP-105i This MSS Standard Practice was developed under the consensus of the MSS Technical Committee 115 and the MSS Coordinating Committee. The content of this Standard Practice is the resulting effor
3、ts of competent and experienced volunteers to provide an effective, clear, and non-exclusive standard that will benefit the industry as a whole. This MSS Standard Practice describes minimal requirements and is intended as a basis for common practice by the manufacturer, the user, and the general pub
4、lic. The existence of an MSS Standard Practice does not in itself preclude the manufacture, sale, or use of products not conforming to the Standard Practice. Mandatory conformance to this Standard Practice is established only by reference in other documents such as a code, specification, sales contr
5、act, or public law, as applicable. MSS has no power, nor does it undertake, to enforce or certify compliance with this document. Any certification or other statement of compliance with the requirements of this Standard Practice shall not be attributable to MSS and is solely the responsibility of the
6、 certifier or maker of the statement. “Unless indicated otherwise within this MSS Standard Practice, other standards documents referenced to herein are identified by the date of issue that was applicable to this Standard Practice at the date of approval of this MSS Standard Practice (see Annex A). T
7、his Standard Practice shall remain silent on the validity of those other standards of prior or subsequent dates of issue even though applicable provisions may not have changed.” By publication of this Standard Practice, no position is taken with respect to the validity of any potential claim(s) or o
8、f any patent rights in connection therewith. MSS shall not be held responsible for identifying any patent rights. Users are expressly advised that determination of patent rights and the risk of infringement of such rights are entirely their responsibility. In this Standard Practice, all text, notes,
9、 annexes, tables, figures, and references are construed to be essential to the understanding of the message of the standard, and are considered normative unless indicated as “supplemental”. All appendices, if included, that appear in this document are construed as “supplemental”. Note that supplemen
10、tal information does not include mandatory requirements. The SI (metric) units and U.S. customary units in this Standard Practice are regarded separately as the standard; each should be used independently of the other. Combining or converting values between the two systems may result in non-conforma
11、nce with this Standard Practice. The U.S. customary units in this Standard Practice are the standard, in cases of conflict or incongruity. Substantive changes contained in this 2016a edition include those changes from the superseded 2016 edition. All substantive changes are “flagged” by parallel bar
12、s as shown on the margins of this paragraph. The specific detail of the 2016a changes may be determined by comparing the material flagged with that in the previous 2010 edition. Excerpts of this Standard Practice may be quoted with permission. Credit lines should read Extracted from MSS SP-105-2016a
13、 with permission of the publisher, Manufacturers Standardization Society of the Valve and Fittings Industry. Reproduction and/or electronic transmission or dissemination is prohibited under copyright convention unless written permission is granted by the Manufacturers Standardization Society of the
14、Valve and Fittings Industry Inc. All rights reserved. Originally Approved: July 1990 Originally Published: October 1990 Superseded 2016 Edition Published: November 2016 Current 2016a Edition Approved: May 2017 Current 2016a Edition Published: June 2017 MSS is a registered trademark of Manufacturers
15、Standardization Society of the Valve and Fittings Industry, Inc. Copyright , 2017 by Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. Printed in U.S.A. MSS STANDARD PRACTICE SP-105ii TABLE OF CONTENTS SECTION PAGE 1 SCOPE . 1 2 DEFINITIONS . 1 3 MATERIALS . 2 4 DESIGN R
16、EQUIREMENTS . 2 5 QUALIFICATION TESTS 3 6 ACCEPTANCE TESTING 5 7 MARKING . 5 FIGURE 1 Direct Mounted Instrument Manifold Gasket Groove and Flange Details U.S. Customary . 6 2 Direct Mounted Instrument Manifold Gasket Groove and Flange Details SI (Metric) 7 ANNEX A Referenced Standards and Applicable
17、 Dates 8 MSS STANDARD PRACTICE SP-1051 INSTRUMENT VALVES FOR CODE APPLICATIONS 1. SCOPE 1.1 This Standard Practice applies to small valves and manifold valves developed for and predominately used in instrument, control, and sampling piping systems for code applications. It covers steel and alloy val
18、ves of nominal pipe size (NPS) 2 and smaller, and pressure ratings of 15,000 psi (103.4 MPa) and lower at 100 F (38 C). See MSS SP-99 for instrument valves not involving code applications. 1.2 This Standard Practice applies to instrument valve designs including, but not limited to, needle valves, pa
19、ckless valves, ball valves, plug valves, check valves, and manifold valves. Instrument valves are generally of proprietary design. This Standard Practice is not intended to define or limit designs, construction, performance, envelope dimensions, or valve types. 1.3 The application of valve type, siz
20、e, rating, materials of construction, and suitability for the service are the responsibility of the purchaser and are outside the scope of this Standard Practice. 2. DEFINITIONS 2.1 General Definitions given in MSS SP-96 apply to this Standard Practice. 2.2 Cold Working Pressure Rating (CWP) The max
21、imum allowable working pressure of a valve at ambient conditions, i.e., -20 F to 100 F (-29 C to 38 C). 2.3 Control Piping Piping used to interconnect pneumatically or hydraulically operated control apparatuses, or to signal control systems. 2.4 Instrument Piping Piping used to connect instruments t
22、o main piping or other instruments. 2.5 Instrument Valves Valves designed for use in instrument, control, and sampling piping systems, (e.g., see ASME B31.1, Article 122.3). 2.6 Manifold Valve Two or more instrument valves fabricated into a single valve body. 2.7 Packless Valve A valve with a diaphr
23、agm or bellows stem seal instead of a packing or O-ring seal at the stem. 2.8 Pressure Boundary Parts The following items are defined to be pressure boundary parts. Each item may not apply to all valve designs. a) Body b) Bonnet c) Union Nut d) Body-to-Bonnet Bolting e) Body Bolting 2.9 Sampling Pip
24、ing Piping used for the collection of samples (such as steam, water, oil, gas, and chemicals) from process systems. MSS STANDARD PRACTICE SP-1052 3. MATERIALS 3.1 General The pressure boundary parts of the valve shall be made of the materials specified herein. 3.2. Non-pressure boundary parts (e.g.,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- MSSSP105A2016INSTRUMENTVALVESFORCODEAPPLICATIONSPDF

链接地址:http://www.mydoc123.com/p-822934.html