1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 - TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU-!).4%.!.#% ).4%2.!4)/.!,G0G04%,%0(/.%G0G0#)2#5)432/54).%G0G0-!).4%.!.#%G0G03#(%$5,%G0G0 an example of its use is givenin Figure 2/M.605.As far as possible the schedule is drawn up on the principle of batch m
2、easurements of circuits on a given routeand shows the days and times during which the routine maintenance measurements should be carried out.Each international test centre will require a set of eight forms to cover the four weeks of the odd and the fourweeks of the even months, four weeks constituti
3、ng a month for the purpose of the schedule.Week 1 is the first whole week of a month beginning with a Monday. Week 4 may include days belonging tothe following calendar month.Odd months denotes January, March, May, etc., and even months February, April, etc.The schedule form allows for simultaneous
4、testing on two different routes where two test positions areprovided for routine measurements. If more than two routine test positions are available, additional or suitably modifiedforms will be required.2.2 Arranging the scheduleThe periodicity for circuit routines should be determined from Recomme
5、ndation M.610.The total time required to routine test all the circuits on a route should be assessed. It will depend on:a) the total number of circuits,b) the type of measurements and tests to be made, andc) the expected rate of completion of routines for each circuit.The determination of item c) wi
6、ll require particular care. The duration of circuit routines may be expected todiffer from one test centre to another due to the different facilities provided: for example, circuit test accessarrangements, and the organization of the work. Thus, no guidance can be given to the expected rate of compl
7、etion ofroutines.To reduce the need to make frequent changes to the schedule, due allowance should be made for any plannedincrease of the number of circuits on a route.The individual testing periods may be of 1, 2, 3 or 4 hours duration. Where the total routine time required for aroute would make a
8、single testing period impracticable, two or more testing periods should be allocated to the route, butthese periods should be separated in time by at least 4 hours._1)In some Administrations this function may be delegated by the technical service, but in all cases the technical services areresponsib
9、le for ensuring the satisfactory preparation and application of the schedule.2 Fascicle IV.1 - Rec. M.605The days and times of the testing periods will be decided by a bilateral agreement between the two technicalservices concerned. To initiate the scheduling of routines for a route, the technical s
10、ervice to which the circuit controlstation is responsible should request copies of the current schedule form from the distant end technical service. Thecontrolling end technical service should indicate on the forms the day(s) and time(s) it proposes, choosing anyunallocated periods on the forms for
11、this purpose. The forms should then be returned to the distant technical service andagreement sought on the proposals2).It is intended that individual testing periods be allocated to the circuits of one control station only. However,subject to the bilateral agreement between the two technical servic
12、es involved, individual testing periods may be used ona common basis for the circuits of both control stations.2.3 Use of echo canceller devicesThe number of echo cancellation stages and the echo path delay characteristics must be stated in order toprogram tests properly using the echo canceller tes
13、t facility as specified in Recommendation O.22 1. Thesecharacteristics should be included in ATME No. 2 schedule forms when exchanged between Administrations. IfATME No. 2 is not used between Administrations, echo canceller delay information should be conveyed by othermeans, for example a telex mess
14、age, or the manual routine testing schedule (Figure 1/M.605).2.4 Changes to the scheduleAs far as possible testing periods should be chosen so that new circuits can be incorporated without change tothe schedule.Modifications to the days and/or times of testing for existing circuits, or expansion of
15、the schedule toaccommodate additional circuits or new routes should be determined by the technical service to which the circuit controlstation is responsible, in agreement with the other interested technical service(s). If the technical service responsible for acircuit sub-control station considers
16、it necessary to alter the routine maintenance schedule, it should propose changes andobtain the agreement of the technical service responsible for the control station. Any intended modifications or additionsto the schedule should be entered in red on a current copy which should be forwarded to the d
17、istant technical service(s)concerned. Agreement or counterproposals can then be made by any suitable means3).2.5 Programming of routine measurements and testsIt is the responsibility of each Administration to decide how the agreed scheduled test periods should beutilized for the effective completion
18、 of routines on the circuits it controls.This will involve determining the type of measurements and tests to be made on each circuit taking intoaccount the recommended periodicities.2.6 Unscheduled periodsAvailable periods in the schedule which are unallocated may be used for any purpose relating to
19、 circuitroutines. Such use is on an ad hoc basis and each occasion must be agreed by the terminal control and sub-controlstations concerned.3 Circuit routines by automatic transmission measuring equipment ATME No. 23.1 Schedule formFor the orderly and effective use of ATME for circuit routines it is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTM6051988ROUTINEMAINTENANCESCHEDULEFORINTERNATIONALPUBLICTELEPHONYCIRCUITS 国际 公用电话 电路 例行 维护 进度表 PDF

链接地址:http://www.mydoc123.com/p-799886.html