1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 , TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU#/.3425#4)/. G0G0).34!,!4)/.G0G0!.$02/4%#4)/.G0G0/ location and purpose of the termination; number or quantity of terminations required; type of service or transmission link involved; flexibility and protecti
2、on requirements.Basically, all exchange, repeater (amplifier or regenerator), and major cross-connection point terminations areof the “fixed” type utilizing wrapping, soldering of insulation displacement connection (IDC) techniques.Local distribution and customer terminations utilize a mixture of “f
3、ix” and “temporary” (screw terminal) typeterminations depending on individual conditions. Where required, over-voltage protection may be provided as anintegral component of the terminating device or a separate “add-on” facility.Within a cable network, two methods of terminating cables are available.
4、 These may generally be referred to asthe direct and indirect methods.Direct termination implies that the conductors associated with a particular cable connected directly to theterminal forming the “end” of the cable circuit, e.g. the cable conductor and terminal are directly coupled.Indirect termin
5、ation implies that the cable conductor is connected to the end terminal via a device thatincorporates a preformed or manufactured termination.Direct terminations are usually utilized in end terminals such as at the exchange main distribution frame (MDF)and customer premises, although some direct ter
6、minations are used in the customer distribution cable area. In mostother mid-point terminations (distribution cabinets and pillars, repeater housings and termination points for trunkcarrier and coaxial cables), indirect terminations utilizing devices with pre-terminating tail cables are spliced into
7、 thebasic bearer cables.The electric conducting parts of terminating devices will be of metal such as copper, brass or other similaralloys suitably plated to resist corrosion and other environmental effects and provide good electrical connection, eitherby contact, pressure, soldering or wrapping.Var
8、ious insulating materials (plastic extrusions and resin moulding) provide the mechanical mounting andelectrical insulation of the metallic components.2 Termination types2.1 Termination types for symmetric pair conductors2.1.1 Wire-wrapping typeIn this type the conductor is wire-stripped and cut, ins
9、erted in a wire-wrap tool and wire-wrapped around theterminal point.2.1.2 Solder-on-typeIn this type the conductor is wire-stripped and cut, then inserted in the terminal slot and soldered.2.1.3 Wrap-and-solder typeIn this type, after wrapping, the conductor is soldered to the cut end of a terminal.
10、2 Volume IX - Rec. L.92.1.4 Binder-post typeThere are different forms of this type:a) Termination by means of screws. The conductor is wire-stripped, cut and fastened with screws by means ofa screwdriver.b) Termination by means of nuts. The termination consists of a fixed threaded brass post contain
11、ing washersand a threaded hex nut. The conductors are terminated between the washers.2.1.5 Insulation displacement contact (IDC) typeIn this type, generally the conductor is installed and pressed into a U-element contact by means of a specialtool.The U-element contact has different forms and is the
12、most frequently used terminating type.2.1.6 Termination for unused conductorsThis termination is made by means of plastic connectors without U-element contacts and is used for theprotection of unused conductors in a pedestal or splice closure.2.2 Termination types for coaxial conductors2.2.1 Connect
13、ors typesCoaxial pairs are terminated in connectors mounted on a metallic diaphragm for accessing the repeater housingof the terminal equipment.The connector joins the stiff coaxial tube to the flexible one leading into the housing or exchange, and isprovided with a device for pneumatic insulation.2
14、.2.2 Direct-joint typeA joint between the air core tube and the flexible coaxial cable is made at times.3 Termination useThe types of termination mentioned above are used in different devices and locations for terminating cables inall their applications: main distribution frame, regenerating equipme
15、nts, cabinets, terminal boxes and subscriberspremises.These devices present some physical characteristics which may vary greatly from country to country, althoughtheir technical features (i.e. electrical and environmental requirements) are very similar.4 Requirements for MDF terminating devicesThe b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL91988METHODSOFTERMINATINGMETALLICCABLECONDUCTORS 电缆 方法 户外 设备 其他 部分 结构 安装 保护 研究 64 PDF

链接地址:http://www.mydoc123.com/p-799603.html