1、 INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.54TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (02/2004) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Splice closure for marinized terrestrial cables (MTC) ITU-T Recommendation L.54 ITU-T Rec. L.54
2、 (02/2004) i ITU-T Recommendation L.54 Splice closure for marinized terrestrial cables (MTC) Summary This Recommendation refers to both the design and the main characteristics that an underwater splice closure for MTC should have in order to be suitable for this application, as well as to guarantee
3、the expected lifetime of the whole transmission link. This Recommendation provides the tests for characterization and evaluation of the underwater splice closures performance, including mechanical integrity and optical stability of the product simulating the effect of the environment (water), as wel
4、l as interventions related to installation and network maintenance. Source ITU-T Recommendation L.54 was approved on 6 February 2004 by ITU-T Study Group 6 (2001-2004) under the ITU-T Recommendation A.8 procedure. ii ITU-T Rec. L.54 (02/2004) FOREWORD The International Telecommunication Union (ITU)
5、is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardiz
6、ing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered
7、 by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate
8、 both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g., interoperability or applicability) and compliance with the Recommendation is achieved wh
9、en all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPER
10、TY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted
11、 by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that
12、 this may not represent the latest information and are therefore strongly urged to consult the TSB patent database. ITU 2004 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. ITU-T Rec. L.54 (02/2004) iii CONTENT
13、S Page 1 Introduction 1 2 Scope 1 3 References. 1 4 Abbreviations and definitions. 2 5 Main characteristics 2 6 Qualification tests . 3 7 Sample preparation . 4 8 Reference measurements 4 9 Tests 4 9.1 Temperature cycling. 5 9.2 Tensile with twist restrained. 5 9.3 Tensile with torque minimized. 6 9
14、.4 Bending under tension (sheave passage) 7 9.5 Repeated bending (optional). 7 9.6 Hydraulic pressure resistance. 8 9.7 Bumps. 8 9.8 Vibration. 9 9.9 Corrosion resistance (optional). 9 Appendix I Examples of different closure designs available on the market. 10 ITU-T Rec. L.54 (02/2004) 1 ITU-T Reco
15、mmendation L.54 Splice closure for marinized terrestrial cables (MTC) 1 Introduction An important part of any installed underwater optical cable system is the jointing between different cable spans. In fact, it is very important that a splice closure utilized for an underwater (i.e., MTC) optical ca
16、ble system is manufactured in order to guarantee not only a good quality of transmission during the expected lifetime, but also cost savings for maintenance purposes. A splice closure comprises a mechanical structure (closure housing) that is attached to the ends of two or more underwater cables, an
17、d a set of boxes (organizers) for containing and protecting the fibres and passive optical devices (if any). As a general rule, the closure housing and the armour terminations, generally designed for a whole MTC family, should be dimensioned for the strongest cable designed for that particular link
18、(maximum tensile strength and maximum pressure resistance). Splice closures for MTC applications may contain fibre splices, mass splices and passive devices. Moreover, since such closures are typically mounted on the cable before it is installed, it should also be designed to withstand all handling
19、and loads that occur during cable installation. 2 Scope This Recommendation details: the mechanical and environmental characteristics of splice closures for MTC applications; the main optical performances that such closures have to guarantee during their lifetimes. 3 References The following ITU-T R
20、ecommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation ar
21、e therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as
22、a stand-alone document, the status of a Recommendation. ITU-T Recommendation G.972 (2000), Definition of terms relevant to optical fibre submarine cable systems. ITU-T Recommendation G.976 (2000), Test methods applicable to optical fibre submarine cable systems. ITU-T Recommendation L.12 (2000), Opt
23、ical fibre joints. ITU-T Recommendation L.13 (2003), Performance requirements for passive optical nodes: Sealed closures for outdoor environments. IEC 60068-2-6:1995, Environmental testing Part 2: Tests Vibration (sinusoidal). IEC 60794-1-2:2003, Optical fibre cables Part 1-2: Generic specification
24、Basic optical cable test procedures (Methods:E1, E6, E7, E18A, F1, F10). 2 ITU-T Rec. L.54 (02/2004) IEC 60794-3-30:2002, Optical fibre cables Part 3-30: Outdoor cables Family specification for optical telecommunication cables for lake and river crossings. IEC 61300-2-22:1995, Fibre optic interconne
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL542004SPLICECLOSUREFORMARINIZEDTERRESTRIALCABLESMTCMARINIZED 陆地 光缆 MARINIZED 剪接 封闭 系列 建造 安装 电缆 保护

链接地址:http://www.mydoc123.com/p-799540.html