ITU-T H 830 11-2017 Conformance of ITU-T H 810 personal health system Services interface Part 11 Questionnaires Health & Fitness Service sender (Study Group 16).pdf
《ITU-T H 830 11-2017 Conformance of ITU-T H 810 personal health system Services interface Part 11 Questionnaires Health & Fitness Service sender (Study Group 16).pdf》由会员分享,可在线阅读,更多相关《ITU-T H 830 11-2017 Conformance of ITU-T H 810 personal health system Services interface Part 11 Questionnaires Health & Fitness Service sender (Study Group 16).pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.830.11 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (04/2017) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (H
2、RN, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health system: Services interface Part 11: Questionnaires: Health Part 11: Questionnaires: HFS Sender (Version 1.2, 2017-03-14). This Recommendation includes an electronic attachment with the protocol implementation conformance statement
3、s (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.830.11 2015-11-29 16 11.1002/1000/12676 2.0 ITU-T H.830.11 2016-07-14 16 11.1002/1000/12931 3.0 ITU-T
4、H.830.11 2017-04-13 16 11.1002/1000/13206 Keywords Conformance testing, Continua Design Guidelines, e-health, Health Part 11: Questionnaires: HFS Sender (Version 1.21, 2017-03-14), that was developed by the Personal Connected Health Alliance. The table below shows the revision history of this test s
5、pecification; it may contain versions that existed before transposition. Version Date Revision history 1.0 2015-07-01 Initial release for Test Tool DG2015 based on the requirements in b-ITU-T H.810 (2015)/b-CDG 2015. 1.1 2016-09-20 Initial release for Test Tool DG2016. It implements changes accordin
6、g to ITU-T H.810 (2016)/b-CDG 2016 (Iris + Errata) refreshments. 1.2 2017-03-14 Editorial: added insulin pump and continuous glucose monitor specializations to the TSS list in clause 6. Rec. ITU-T H.830.11 (04/2017) 1 Recommendation ITU-T H.830.11 Conformance of ITU-T H.810 personal health system: S
7、ervices interface Part 11: Questionnaires: Health users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly publis
8、hed. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 (2016) Recommendation ITU-T H.810 (2016), Interoperability design guidelines for personal health systems. ITU-T H.811 Recommendation ITU-T H.811 (2016)
9、, Interoperability design guidelines for personal health systems: Personal health devices interface. 1 This Recommendation includes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required f
10、or the implementation of Annex A. 2 Rec. ITU-T H.830.11 (04/2017) ITU-T H.812 Recommendation ITU-T H.812 (2016), Interoperability design guidelines for personal health systems: Services interface: Common certified capability class. ITU-T H.812.1 Recommendation ITU-T H.812.1 (2016), Interoperability
11、design guidelines for personal health systems: Services interface: Observation upload certified capability class. ITU-T H.812.2 Recommendation ITU-T H.812.2 (2016), Interoperability design guidelines for personal health systems: Services interface: Questionnaires certified capability class. ITU-T H.
12、812.3 Recommendation ITU-T H.812.3 (2016), Interoperability design guidelines for personal health systems: Services interface: Capability exchange certified capability class. ITU-T H.812.4 Recommendation ITU-T H.812.4 (2016), Interoperability design guidelines for personal health systems: Services i
13、nterface: Authenticated persistent session certified capability class. ITU-T H.813 Recommendation ITU-T H.813 (2016), Interoperability design guidelines for personal health systems: Healthcare information system interface. HL7 CDA QFD Health Level Seven (2014), HL7 Implementation Guide for CDA, Rele
14、ase 2: Questionnaire Form Definition Document, Release 1. http:/www.hl7.org/dstucomments/showdetail.cfm?dstuid=116 HL7 CDA QRD Health Level Seven (2014), HL7 Implementation Guide for CDA, Release 2: Questionnaire Response Document, Release 1. http:/www.hl7.org/dstucomments/showdetail.cfm?dstuid=117
15、3 Definitions 3.1 Terms defined elsewhere None. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: AHD Application Hosting Device ATS Abstract Test Suite ATNA Audit Trail and Node Authentication DUT Device Un
16、der Test CDG Continua Design Guidelines CGM Continuous Glucose Monitor GUI Graphical User Interface HFS Health M RESTSec 4;M RESTSec 5;M CommonReq 5;M Spec ITU-T H.812.2 Testable items Question 1;M Question 3;M Question 5;M Test purpose Check that: SUT retrieves a list of to-be-completed questionnai
17、res from simulated HFS application and an actual to-be-completed questionnaire document. Applicability C_SEN_000 AND C_SEN_GEN_004 AND C_SEN_GEN_006 Other PICS C_SEN_GEN_005 Initial condition The simulated HFS receiver provides a list of to-be-completed questionnaires with a single entry containing
18、a link to an actual to-be-completed questionnaire document. Test procedure 1. An HFS application uses an HTTP GET request without query parameters at the URL representing the patients questionnaire hData root section path (continua/questionnaires) using a secure hData connection in order to retrieve
19、 an atom feed containing a list of to-be-completed questionnaire documents containing one document. 2. An HFS application retrieves the actual to-be-completed questionnaire document using the value of the “link“ element contained in the atom feed retrieved in step 1. “Link“ element content will be a
20、 relative path to baseURL (WanReceiver). 3. An HFS application validates received document according to Questionnaire Form Definition Document HL7 CDA QFD. Pass/Fail criteria An HFS application under test supports capability exchange as specified in ITU-T H.812.3. An HFS application successfully ret
21、rieves the list of to-be-completed questionnaires from the simulated HFS application. An HFS application successfully retrieves the actual to-be-completed questionnaire document using the content of the “link“ element in the atom feed. An HFS application confirms that the questionnaire document has
22、been validated. Notes TP Id TP/HFS/SEN/QUE/GEN/BV-001 TP label Questionnaire response submitting. HFS Sender. Coverage Spec ITU-T H.812 Testable items RESTSec 3;M RESTSec 4;M RESTSec 5;M CommonReq 5;M Spec ITU-T H.812.2 10 Rec. ITU-T H.830.11 (04/2017) Testable items Question 6;M Test purpose Check
23、that: SUT posts a questionnaire response document to the simulated HFS receiver. Applicability C_SEN_000 AND C_SEN_GEN_004 AND C_SEN_GEN_006 Other PICS C_SEN_GEN_005 Initial condition The simulated HFS receiver is ready to receive a questionnaire response document from the HFS sender under test. Tes
24、t procedure 1. A questionnaire-enabled HFS sender under test uses HTTP POST with the following URL for posting a questionnaire response document to the simulated HFS Device: baseURL/continua/questionnaireResponse. Connection uses TLSv1.1 and an Oauth2 bearer token. Pass/Fail criteria An HFS applicat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTH830112017CONFORMANCEOFITUTH810PERSONALHEALTHSYSTEMSERVICESINTERFACEPART11QUESTIONNAIRESHEALTHFITNESSSERVICESENDERSTUDYGROUP16PDF

链接地址:http://www.mydoc123.com/p-797915.html