1、 Recommendation ITU-R SM.2080-0 (08/2015) Precision of time information in output data of monitoring receivers SM Series Spectrum management ii Rec. ITU-R SM.2080-0 Foreword The role of the Radiocommunication Sector is to ensure the rational, equitable, efficient and economical use of the radio-freq
2、uency spectrum by all radiocommunication services, including satellite services, and carry out studies without limit of frequency range on the basis of which Recommendations are adopted. The regulatory and policy functions of the Radiocommunication Sector are performed by World and Regional Radiocom
3、munication Conferences and Radiocommunication Assemblies supported by Study Groups. Policy on Intellectual Property Right (IPR) ITU-R policy on IPR is described in the Common Patent Policy for ITU-T/ITU-R/ISO/IEC referenced in Annex 1 of Resolution ITU-R 1. Forms to be used for the submission of pat
4、ent statements and licensing declarations by patent holders are available from http:/www.itu.int/ITU-R/go/patents/en where the Guidelines for Implementation of the Common Patent Policy for ITU-T/ITU-R/ISO/IEC and the ITU-R patent information database can also be found. Series of ITU-R Recommendation
5、s (Also available online at http:/www.itu.int/publ/R-REC/en) Series Title BO Satellite delivery BR Recording for production, archival and play-out; film for television BS Broadcasting service (sound) BT Broadcasting service (television) F Fixed service M Mobile, radiodetermination, amateur and relat
6、ed satellite services P Radiowave propagation RA Radio astronomy RS Remote sensing systems S Fixed-satellite service SA Space applications and meteorology SF Frequency sharing and coordination between fixed-satellite and fixed service systems SM Spectrum management SNG Satellite news gathering TF Ti
7、me signals and frequency standards emissions V Vocabulary and related subjects Note: This ITU-R Recommendation was approved in English under the procedure detailed in Resolution ITU-R 1. Electronic Publication Geneva, 2015 ITU 2015 All rights reserved. No part of this publication may be reproduced,
8、by any means whatsoever, without written permission of ITU. Rec. ITU-R SM.2080-0 1 RECOMMENDATION ITU-R SM.2080-0 Precision of time information in output data of monitoring receivers (2015) Scope This Recommendation provides examples of possible measurement methods for the accuracy of the time infor
9、mation in I/Q data of a monitoring receiver. Keywords I/Q data, time stamp accuracy The ITU Radiocommunication Assembly, considering a) that precise time information in I/Q data is of great relevance in the field of radio monitoring; b) that ambiguities of the time stamp specification between users
10、and different manufacturers may lead to misunderstanding of time information in the I/Q data; c) that the internal clock of a monitoring receiver will drift if no measures are taken to maintain timing accuracy; d) that, depending on the settings of a monitoring receiver, there are different time del
11、ays between the arrival of the signal at the RF input connector and the moment of the insertion of the precise time information in the I/Q data; e) that a well-defined specification for precise time information in I/Q data, if adopted by manufacturers of radio monitoring receivers, will benefit user
12、s by providing an easier and more objective comparison of similar products from different manufacturers, recommends 1 that the accuracy of the time information in the I/Q data stream is constant for every sample pair (I/Q) in order to be able to mark even short-duration, intermittent or pulsed signa
13、ls with the same accuracy; 2 that the precise time information in the I/Q-data is referenced to the RF input connector of the monitoring receiver to prevent the signal propagation delay in the receiver from influencing the time stamp; 3 that the internal clock of a monitoring receiver is synchronize
14、d with a high precision clock; 4 that the accuracy of the time information in I/Q data of a monitoring receiver is defined by the deviation between the reference time and the time stamp provided by the receiver, expressed by mean value and standard deviation; 5 that the accuracy of the time informat
15、ion in I/Q data of a monitoring receiver and the measurement method is specified by the manufacturer in their datasheet. Examples of possible methods are shown in the annexes. 2 Rec. ITU-R SM.2080-0 Annex 1 Definition of the time stamp accuracy of radio monitoring receivers 1 Scope For a number of a
16、pplications in the field of radio monitoring, highly precise time information in monitoring receivers is necessary. This Annex provides a definition of time stamp accuracy in the I/Q data of a monitoring receiver. This definition should be adopted as a common understanding of the terms and used in p
17、roduct technical data by all manufactures of radio monitoring receivers. 2 Clarification The time stamp accuracy consists of two parts. One is how well the receiver is synchronized with the reference time; the other is how well the signal transmission time within the receiver is compensated. FIGURE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITURSM208002015PRECISIONOFTIMEINFORMATIONINOUTPUTDATAOFMONITORINGRECEIVERS 监测 接收器 数据 输出 时间 信息 准确性 PDF

链接地址:http://www.mydoc123.com/p-794124.html