1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2008 by Navistar, Inc. DECEMBER 2008 Page 1 of 5 NAVISTAR, INC. TMS (TRUCK MATERIAL SPECIFICATION) NUMBER
2、: TMS-1068 srr TITLE: Bellows Flexible Pipe CURRENT REV No.: 0812 DATE: December 2008 WRITTEN/EDITED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES: N/A PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may involve hazardous materials,
3、equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change Notice: NEW Reference: 0
4、7 Keywords: Exhaust Pipe; Flexible Pipe/Hose; Bellows 1.0 APPLICATION This specification covers two types of bellows (flexible steel pipe) used for making connections between pipes used in the exhaust system. Each application needs to be developed on a case by case basis due to the differences in di
5、splacement and/or vibrations in the different vehicle/application/location. The bellows described in this document is to be used when raw fuel is present in the exhaust gas traveling through the piping, or when spiral wound flex (TMS-1050) cannot meet the leak rate required by the engine/aftertreatm
6、ent provider. Spiral wound flex per TMS-1050 may be used if it is after the treatment areas (DOC, DPF, SCR) of the exhaust system or there is no raw fuel or other reactant present in the exhaust gas at that point. 2.0 SCOPE This specification covers requirements for the material, construction, dimen
7、sions, quality, leakage, installation, design guidance, source approval and quality control, for both types of bellows. TYPE I is meant to be used in high temperature applications as the liner insulates the bellows from the exhaust gas heat, or to act as a dual wall pipe to insulate surrounding comp
8、onents from the exhaust heat. TYPE I - Bellows with inner liner TYPE II - Bellows only Additional qualifiers: A Materials Engineering and Aftertreatment Engineering group must provide written approval prior to use of alternate materials. Aftertreatment Engineering may make modifications to the mater
9、ial requirements when application guidelines from Engine Manufacturers dictate. All vendor prints must indicate all material types and specifications comprising a bellows assembly. 4.2 Construction Bellows shall be constructed of a series of corrugations that allow flexibility, so as to require a ma
10、ximum pulling force of 35 pounds to achieve an extension of 15% from the nominal length. Extension shall be 2.5 in/ft minimum from the compressed position. The end treatment of the bellows should be designed for welding or attachment to pipes with clamps based on TMS 1058, Figure 5B. Both ends shall
11、 have all burrs removed. 4.3 Leakage Rate Maximum leakage rate of bellows in the designed to position shall be less than 0.01 standard cubic feet of air per minute at 10 psig. 4.4 Dimensions Bore Diameter - Type I this only applies to the interface area between the pipe and the bellows. 4.5 Length -
12、 applies to both Type I and Type II There is no rule of thumb for the proper length for bellows as there is with spiral wound flex pipe. The required length for a design will depend on how much movement is necessary, and the vibration loads from the engine. Packaging also plays a role in the length.
13、 The supplier will need to determine the length of the bellows based on their design (number height and size of ribs/corrugations). Nominal length is the non-stressed length or free length of the bellows. 4.6 Installation Install bellows such that it is at its nominal or non-stressed state. The inle
14、t and outlet of the bellows should be in a straight line when installed in the vehicle. 4.6.1 Flow Direction The flex hose shall be installed in the truck exhaust system in such a manner that the flow direction label on the hose is aligned with the direction of the exhaust gas flow. 4.6.1.1 Flow Dir
15、ection Labeling Type I bellows construction having an inner liner may have a preferential direction of gas flow through the bellows. The bellows shall be marked on the outside of the bellows to indicate the preferred direction of flow. The method of marking and frequency of the markings shall be agr
16、eed upon between Engineering, the Quality Department of the receiving NAVISTAR Plant(s), and the supplier. Upon agreement, no changes in the marking procedure/process will be made without the prior approval of Engineering and the Plant Quality Department(s). An example of an approved marking is show
17、n in Figure 1. NAVISTAR engineering assembly drawings should specify the flow direction when this type of bellows is used in the assembly. 4.7 Welding bellows to pipe 4.7.1 Weld Quality 4.7.1.1 Appearance Welds should be smooth, continuous, and encompass the entire flex hose-to-pipe joint. Start and
18、 stop points, which create stress risers in the bellows assembly which could lead to premature failure, are prohibited. Welds and surrounding areas should be free of excessive weld spatter and/or heat damage. 4.7.1.2 Leak Rate The total leak rate for the welded assembly should not exceed the leak ra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- INTERNTMS10682008BELLOWSFLEXIBLEPIPE 波纹 柔性 PDF

链接地址:http://www.mydoc123.com/p-786073.html