1、ANSIjICEA 5-70-547-2007 -!I . . IV:I STANDARD FOR WEATHER-RESISTANT POLYETHYLENE COVERED CONDUCTORS Approved by AMERICAN NATIONAL STANDARDS INSTITUTE September 27, 2007 Publication # ANSIIICEA S 70-547-2007 2007 by leEA INSULATED CABLE ENGINEERS ASSOCIATION, Inc. Approved as an American National Sta
2、ndard ANSI Approval Date: September 27, 2007 AN51/1CEA Publication 5-70-547-2007 standard For Weather-Resistant Polyethylene Covered Conductors Developed and Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, Georgia, 30112, USA Copyright 2007 by the Insulated
3、Cable Engineers Association, Incorporated. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. NOTICE AND DISCLA
4、IMER The information in this publication was considered technically sourid by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the d
5、evelopment of this document. The Insulated Cable Engineers Association, Inc. (ICEA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together persons who have an interes
6、t in the topic covered by this publication. While ICEA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgements contained i
7、n its standards and guideline publications. ICEA disclaims liability for personal injury, property, or other damages of any nature whatsoever, whether special, indirect consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this doc
8、ument. ICEA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. ICEA does not undert
9、ake to guarantee the performance of any individual manufacturer or sellers products or services byvirtue of this standard or guide. In publishing and making this document available, ICEA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is ICEA
10、 undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgement or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Inf
11、ormation and other standards on the topiC covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. ICEA has no power, nor does it undertake to police or enforce compliance with the content
12、s of this document. ICEA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to ICEA and is solely the respons
13、ibility of the certifier or maker of the statement. Section I 1.1 1.2 1.3 1.4 1.5 Section 2 2.0 2.1 2.2 2.3 2.4 2.5 Section 3 3.1 3.2 3.3 3.4 Section 4 4.1 4,2 Section 5 5.1 5.2 5.3 5.4 ICEA S-70-547-2007 Page i Contents Page Foreword iii General Scope 1 Design Options 1 Operating Conditions 2 Testi
14、ng and Test Frequency 2 Test Methods 2 Conductors General 3 Physical and Electrical Properties 3 2.1.1 Copper Conductors 3 2.1.2 Aluminum Conductors 3 2.1.3 Aluminum Conductor, Coated-Steel Reinforced. 4 2.1.4 Aluminum Conductor, Aluminum-Clad Reinforced 4 2.1.5 Copper and Copper-Clad Steel Composit
15、e 4 Conductor Size Units. 4 Conductor dc Resistance Per Unit Length 4 2.3.1 Direct Measurement of dc Resistance Per Unit Length 5 2.3.2 Calculation of dc Resistance Per Unit Length 5 Conductor Rated Strength 5 Conductor Diameter 6 Covering Material 7 3.1.1 Requirements for 75C Covering for Normal Se
16、rvice Operation 7 3.1.2 Requirements for 90C Covering for Normal Service Operation 7 Covering Thickness Requirements 7 Covering Physical Requirements 7 Separator T Performance Requirements For Finished Conductors General 16 Strength of Covered Conductors 16 Test Methods For Coverings Method for Meas
17、uring Covered Physical and Air Oven Aging Properties 17 Method for Measuring Covering Heat Deformation 17 (Distortion) Method for Measuring Covering Hot Creep 17 Method for Measuring Absorption Coefficient 17 2007 by the Insulated Cable Engineers Association, Incorporated -.-.-? ICEA S-70-547-2007 P
18、age ii Section 6 6.1 6.2 6.3 APPENDICES A B C LIST OF TABLES 3-1 3-1 (Metric) 3-2 3-2 (Metric) 3-3 3-3 (Metric) 3-4 3-4 (Metric) 3-5 6-1 Qualification Tests General Method for Determining Resistance to Environmental Stress Cracking Sunlight Resistance of Covering Materials with Less than 2 Percent C
19、arbon Black 6.3.1 Qualification . 6.3.2 Sunlight Resistance 6.3.2.1 Carbon-Arc Weather-O-Meter 6.3.2.2 Xenon-Arc Weather-O-Meter Titles and Dates of Industry Standards Referenced in this Document Recommended Bending Radii for Covered Conductors English/Metric Conversion Aluminum 1350 Conductor Const
20、ructions Aluminum 1350 Conductor Constructions Aluminum Conductors, Coated-Steel Reinforced (ACSR), and Aluminum Clad Steel Reinforced (ACSRlAW) Constructions Aluminum Conductors, Coated-Steel Reinforced (ACSR), and Aluminum Clad Steel Reinforced (ACSRlAW) Constructions Aluminum-Alloy 6201-T81 Condu
21、ctor Constructions Aluminum-Alloy 6201-T81 Conductor Constructions Copper Conductor Constructions. Copper Conductor Constructions Covering Physical Requirements Qualification Test Requirements 2007 by the Insulated Cable Engineers Association, Incorporated 18 18 18 18 18 18 18 20 22 22 8 9 10 11 12
22、12 13 14 15 19 Foreword ICEA S-70-547-2007 Page iii ICEA standards and guides are adopted in the public interest and are designed to eliminate misunderstanding between the manufacturer and user and to assist the user in selecting and obtaining proper products for his particular need. Existence of an
23、 ICEA standard or guide does not in any respect preclude the manufacture or use of products not conforming to the standard or guide. The user of this Standard is cautioned to observe any applicable health or safety regulations and rules relative to the manufacture and use of cable made in conformity
24、 with this Standard. This Standard hereafter assumes that manufacture, testing, installation and maintenance of cables defined by this publication will be performed only by properly trained personnel using suitable equipment. Requests for interpretation of this Standard must be submitted in writing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ICEAS705472007WEATHERRESISTANTPOLYETHYLENECOVEREDCONDUCTORS 风化 烯烃 电线 电缆 PDF

链接地址:http://www.mydoc123.com/p-783234.html