1、ICEA S-67-401-2005 STANDARD FOR STEEL ARMOR AND ASSOCIATED COVERINGS FOR IMPREGNATE-PAPER INSULATED CABLES Publication # ICEA S-67-401-2005 2005 by INSULATED CABLE ENGINEERS ASSOCIATION, INC. STANDARD FOR STEEL ARMOR AND ASSOCIATED INSULATED CABLES COVERINGS FOR IMPREGNATE-PAPER Standard ICEA S-67-4
2、01-2005 Published By INSULATED CABLE ENGINEERS ASSOCIATION, Inc. Post Office Box 1568 Carrollton, Georgia 301 12, U.S.A. Approved by Insulated Cable Engineers Association, Inc.: December, 2004 o Copyright 2005 by the Insulated Cable Engineers Association, Inc. All rights including translation into o
3、ther languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the international and Pan American Copyright Conventions. O 2005 by the Insulated Cable Engineers Association. ICEA S-67-401-2005 NOTICE AND DISCLAIMER The i
4、nformation in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development
5、of this document. The Insulated Cable Engineers Association (ICEA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together persons who have an interest in the topic co
6、vered by this publication. While ICEA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards an
7、d guideline publications. ICEA disclaims liability for personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. ICEA discl
8、aims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. ICEA does not undertake to guarantee
9、the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, ICEA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is ICEA undertaking to
10、perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and othe
11、r standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. KEA has no power, nor does it undertake to police or enforce compliance with the contents of this document
12、. ICEA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to KEA and is solely the responsibility of the cert
13、ifier or maker of the statement. O 2005 by the Insulated Cable Engineers Association. ICEA S-67-40 1-2005 Page i CONTENTS Page SECTION 1 GENERAL . 1 1.1 SCOPE 1 1.2 TYPES OF STEEL ARMOR AND CONDITIONS OF INSTALLATION i SECTION 2 MATERIALS, CONSTRUCTIONS, AND REQUIREMENTS . 2 2. I 2.2 2.3 2.4 2.5 BED
14、DING FOR ARMORED CABLE 2 2.1.1 Application . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . .2 2.1.2 Direction of Lay . 2.1.3 Thickness . . . . . . . . . PLAIN AND ZINC-COATED STEEL TAPE FOR FLAT TAPE ARMOR 2 2.2.1 Width of Tape . . . . . . . . . . . . . . . . . . . , . . . . . . . . . .
15、. . . . . . . . . , 2 2.2.2 Thickness of Tape . 2 2.2.3 Application, Lay, and Spacing 2 2.2.4 Tensile Strength and Elongation . 3 2.2.5 Galvanizing Tests for Zinc-coated Steel Tape 3 ZINC-COATED LOW-CARBON-STEEL WIRE ARMOR 3 2.3.1 Buried Cable . . . ._. 3 2.3.2 Submarine Cable ., . 3 2.3.3 Requireme
16、nts for Wire to be Used in Armoring . 4 OVERALL SERVING FOR ARMORED CABLE 4 2.4.1 Application . 4 2.4.2 Direction of Lay 4 THERMOPLASTIC COVERING FOR ARMORED CABLE 5 2.5.1 Application . 5 2.5.2 Thickness . 5 ._._ 5 2.5.3 Alternating-current Spark Test SECTION 3 ELECTRICAL TESTS ON ARMORED CABLE 8 3.
17、1 3.2 TESTS AFTER INSTALLATION TESTS TO BE MADE AT THE FACTORY 8 8 SECTION 4 APPENDICES . 9 APPENDIX A INSTALLATION INFORMATION . 9 APPENDIX B REFERENCED STANDARDS . 9 O 2005 by the Insulated Cable Engineers Association. ICEA S-67-401-2005 Page ii Foreword This Standards Publication for Steel Armor
18、and Associated Coverings for Impregnated-Paper-Insulated Cables was developed by the Insulated Cable Engineers Association (ICEA) . KEA Standards are adopted in the public interest and are designed to eliminate misunderstanding between the manufacturer and the user and to assist the user in selectin
19、g and obtaining the proper product for his particular need. Existence of an ICEA Standard does not in any respect preclude the manufacture or use of products not conforming to the standard. The user of this Standard is cautioned to observe any health or safety regulations and rules relative to the m
20、anufacture and use of cable made in conformity with this Standard. Requests for interpretation of this Standard must be submitted in writing to: Insulated Cable Engineers Association P.O. Box 1568 Carrollton, GA 301 12, USA An official written interpretation will be provided once approved by ICEA. S
21、uggestions for improvements gained in the use of this Standard will be welcomed by the Association. O 2005 by the Insulated Cable Engineers Association ICEA S-67-401-2005 Page 1 Section 1 GENERAL 1 .I SCOPE This Standards Publication applies to materials, constructions, and requirements for steel ar
22、mor and associated coverings for impregnated-paper-insulated cables for use in power circuits. There may be installation, operating, or service conditions which require the use of armor and associated coverings which do not meet the requirements of these standards, e.g., nonmagnetic armor on single-
23、 conductor cable for use in alternating-current circuits. (This paragraph has been approved as Authorized Engineering Information.) 1.2 TYPES OF STEEL ARMOR AND CONDITIONS OF INSTALLATION (a) Flat tape armor 1. With an outer covering for use on cables for direct burial. 2. Without an outer covering
24、for use on cables supported by an aerial messenger strand. (b) Wire armor, with or without an outer covering and with either a fibrous bedding or jacket for use on submarine cables or on cables for direct burial. O 2005 by the Insulated Cable Engineers Association. ICEA S-67-401-2005 Page 2 Section
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ICEAS674012005STEELARMORANDASSOCIATEDCOVERINGSFORIMPREGNATEPAPERINSULATEDCABLESPDF

链接地址:http://www.mydoc123.com/p-783233.html