GSA RR-F-00625 A-1965 FRAME FILE DRAWER《文档制图框架》.pdf
《GSA RR-F-00625 A-1965 FRAME FILE DRAWER《文档制图框架》.pdf》由会员分享,可在线阅读,更多相关《GSA RR-F-00625 A-1965 FRAME FILE DRAWER《文档制图框架》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、RR-F-00625a (MA-FSS ) June 15, 1965 Revision of Int . Fed. Spec. m-F-00625( MA-FSS) December 18, 1964 INTERIM FEDERAL SPECIFICATION FRAhE, FILE DRAWER This Interim Federal Specification was developed by the Standardization Division, Federal Supply Service, General Services Administration, Washington
2、, D. C. 20406, based upon currently available technical infor- mation. and forward recommendations for changes to the preparing activity at the address shown above, It is recommended that Federal agencies use it in procurement 1. SCOPE AND CLASSIFICATION 1.1 Scope. and desk file drawers. This specif
3、ication covers metal file drawer frames to be used in file cabinets 1.2 Classification. 1.2.1 Type and grade. 1.2.2 Sizes. (See 3.3 and 6.2). 2. APPLICABLE SPECLFICATIONS AND STANDARDS 2.1 The following specifications and standards, of the issues in effect on date of The file drawer frames shall be
4、of one type and one grade. invitation for bids, form a part of this specification. Federal Specifications: PPP-B-566 - Boxes, Folding, Paperboard. PPP-B-585 - Boxes, Wood, Wirebound. PPP-B-591 - Boxes, Fiberboard, Wood-Cleated. PPP-B-601 - Boxes, Wood, Cleated-Plywood. PPP-B-621 - Boxes, Wood, Naile
5、d and Lock-Corner. PPP-B-636 - Box, Fiberboard. PPP-B-640. - Boxes, Fiberboard, Corrugated, Triple Wall, PPP-B-665 - Boxes, Paperboard, Eletal Stayed (Including Stay Material PPP-B-676 - Boxes, Set-up, Paperboard. UU-P-121 - Paper, Bond and Writing, white and Colored. Federal Standards: Fea. Std. No
6、. 102 - Preservation. Packaging and Packing Levels. I Fed. Std. No. 123 - Marking for Domestic Shipment (Civilian Agencies) THIS DOCUMENT CONTAINS 5 - PAGES. FSC 7520 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-RR-F-00625A 75 m 7797774 004023 7 m
7、 m-F-O0625a( GSA-FSF) Military Standards: MIL-STD-lo5 - Sampling Procedures and Tables for Inspection by Attributes. MIL-STD-129 - Marking for Shipment and Storage. 3. REQUIREMENTS 3.1 Material. The frame shall be of steel with a corrosion resistant coating or plating and shall be of sufficient rigi
8、dity to meet the requirements of this specification. The frame shall show no rust when tested as described in 4.5.2. The coating or plating shall not crack or flake off when tested in accordance with 4.5.3. 3.2 Construction and design. The construction shall be such as to assure compliance with the
9、requirements specified herein when examined in accordance with 4.3 and tested in accordance with 4.5. than i14 inch. screwdriver and pliers or by toolless assembly. The frame shall be designed to hold the side rails in a parallel position in a manner that they will not separate from the end supports
10、 when tested in accordance with 4.5.4. wide. for a distance of not less than 2-718 inches on one end, to permit break-off for use of the frame in drawers of various depths. may be from 318 to 314 inch. the notched side rails are not required. When tested in accordance with 4.5.1 the midpoint of the
11、side rails shall not sag more The frame shall be designed for easy assembly, either with the use of a common The side rails shall be 118 2 1/32 inch thick and not less than 112 inch They shall be rounded on the edges to promote sliding of the file folders and shall be notched The notching shall be a
12、t 112 inch intervals, except that the end notch If the frame is designed to telescope for a minimum of 2-718 inches, 3.3 Dimensions. Dimensions of the frames shall be as specified in table I. TABLE I.- Dimensions Height I Width Depth Between Inside I To TOD I aximum I Overa 1 Overall I Between End e
13、dges of side - Size of siae Overall at Bottom at Top Supports. Rails. Adjacent Rails 2 i18 - + 114 Maximum Fully extended to Supports. Inches Inches Inches Inches Inches Inches Minimum L 1/16 Letter 9-318 10 11-718 12-314 26 12 Legal I 9-318 10 I 14-718 I 15-3/h I 26 I 15 3.4 Identification marking.
14、 Each frame shall be marked with the manufacturers name or trademark of such known character that the source of manufacture may be readily determined. 3.5 Workmanship. The frames shall be free from foreign matter, scratches, scuffs, dents, burrs, pits, or any other defects that may affect serviceabi
15、lity. 4. 4.1 Responsibility for inspection. SAXLING, INSPECTION, AND TEST PRWEDURES Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements as specified herein. laboratory acceptable to the Government. inspections s
16、et forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Except as otherwise specified, the supplier may utilize his own facilities or any commercial The Government reserves the right to perform any of the 4.2 Sampl
17、ing. -2- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- RR-F-00625A 75 m 7777774 0040824 7 m RR-F-00625 illegible; improper size, location, sequence, or method of application. Materials Workmanship Any component missing, or damaged. Inadequate appi
18、cation of components such as incomplete closure of container flaps, loose strapping, inadequate stapling. Bulging or distortion of container. -3 - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-RR-F-00625A 75 7777774 0040825 O 0 RR-F-O0625a( GA-FSS
19、4.5 Tests. Samples taken in accordance with 4.2.4 shall be tested in accordance with 4.5.1, 4.5.2,4.5.3 and 4.5.4. If the number of defective units in the sample exceeds the acceptance number for tha2 sample, the entire lot represented by the sam le shall be reje,cted. laboratory temperature of 70 F
20、. 2 10 F. and a relative humidity of 50 percent 2 10 percent. An assembled file frame, adjusted to its maximum depth, shall be Place in each folder 500 sheets of bond paper, 8xio+ inches, conforming Any frame in the sample having one or more defects shall be reJ%-Led. Tests shall be performed at a 8
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GSARRF00625A1965FRAMEFILEDRAWER 文档 制图 框架 PDF