GPA STD 2188-2014 Method for the Determination Of Ethyl Mercaptan in LP-Gas Using Length of Stain Tubes.pdf
《GPA STD 2188-2014 Method for the Determination Of Ethyl Mercaptan in LP-Gas Using Length of Stain Tubes.pdf》由会员分享,可在线阅读,更多相关《GPA STD 2188-2014 Method for the Determination Of Ethyl Mercaptan in LP-Gas Using Length of Stain Tubes.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 GPA Standard 2188-14 Method for the Determination Of Ethyl Mercaptan in LP-Gas Using Length of Stain Tubes Adopted as a Standard 1988 Revised 2014 Gas Processors Association 6526 East 60th Street Tulsa, Oklahoma 74145 DISCLAIMER GPA publications necessarily address problems of a general nature and
2、may be used by anyone desiring to do so. With respect to particular circumstances, local, state, and federal laws and regulations should be reviewed. Every effort has been made by GPA to assure accuracy and reliability of the information contained in its publications. It is not the intent of GPA to
3、assume the duties of employers, manufacturers, or suppliers to warn and properly train employees, or others exposed, concerning health and safety risks or precautions. GPA makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any liability
4、 or responsibility for loss or damage resulting from its use or for the violation of any federal, state, or municipal regulation with which this publication may conflict, or for any infringement of letters of patent regarding apparatus, equipment, or method so covered. Copyright2014 by Gas Processor
5、s Association. All rights reserved. No part of this Report may be reproduced without the written consent of the Gas Processors Association. Impact Statement Standard for Determination of Ethyl-Mercaptan in LP Gas Using a Length of Stain Tubes GPA 2188 Purpose This standard covers the determination o
6、f the concentration of Ethyl-Mercaptan in LP Gas using a length of stain tube. While other mercaptans and sulfur species may be indicated in this stain tube it is important to remember that the tubes are calibrated for and intended to be used to determine the concentrations of Ethyl Mercaptan in LP
7、Gas. This standard has seen only reprinting and no revisions since 1989, when it was adopted as a tentative method. It was revised in 1989 and reprinted in 1990 and 1998. In 1989 major studies were performed by Sung I. Johnson and W.J. Hines. At that time the team evaluated four brands of tubes and
8、developed accuracy statements which would hold true today and were actually better than, in most cases, the manufacturers stated accuracies. The current revision updates some materials used in the procedures which by todays best practices would be found obsolete in terms of what we would use to coll
9、ect or transport a sample to the stain tube, i.e. gum rubber tubing, etc. The most significant addition to the standard is a “Cautionary Statement”. The intention of the statement is to inform the user that it is critical that manufacturers instructions be followed implicitly. Each lot of stain tube
10、s is tested by the manufacturer for compliance to stated accuracy and each lot or box of stain tubes quite possibly is slightly different in terms of how they are to be used, i.e. exposure times, indicating colors or contaminants, etc. Further the manufacturers instructions will state the exponent t
11、o be used for multiple or partial testing “pulls” of the pump or if these are allowed at all. This information may vary from lot to lot and from one brand of tube to another. Also of significance is the concept that if high accuracy and repeatability is required and chromatography is not indicated o
12、r feasible, then there is many portable handheld electronic devices which offer these things, as well as low power usage and intrinsic safety. So the user should consider if a length of stain tube is really the best commercially available option based on their situation and requirements. Impact It i
13、s not expected that the use of this Standard will have any new or further impact. The users of this Standard should perform their own economic evaluation to include the use of handheld portable electronic devices as applicable. Method for the Determination Of Ethyl Mercaptan in LP-Gas Using Length o
14、f Stain Tubes 1.0 Cautionary Statement The need to determine the concentration of Ethyl Mercaptan in Propane can be driven by numerous factors, including safety related incidents. The user should be aware that if definitive, highly accurate and repeatable readings are needed, length of stain tubes m
15、ay not be the first choice as a commercially viable solution. In recent years there have been advancements in the determination of components of interest in various gases and liquids by means of portable electronic devices (which are outside the scope of this document). Concentration level accuracie
16、s can be greatly enhanced by the use of these electronic devices and of course chromatographic analysis can be the most accurate means of determining the concentration levels of components of interest. The analytical results are highly dependent on many factors. Therefore, it is imperative that the
17、user read, understand and follow the instructions in each box of tubes implicitly (since every box or lot of tubes potentially has its own individual characteristics). Interferences may include temperature and moisture content of the material under test, ambient conditions, and a number of other dil
18、uents and contaminants. Ambient or operational conditions may preclude the use of a stain tube. It may be too hot or humid outside or the conditions in the Propane may not be appropriate for stain tube use. Manufacturers instructions will direct the user. Stain tube accuracies as stated by most manu
19、facturers is 25%. While GPA testing shows 10% accuracy in controlled conditions, it is important for the user to determine if the stated accuracy by the stain tube manufacturer is acceptable, based on the operational conditions, ambient conditions and operational and safety requirements for the dete
20、rmination of the concentration level of Ethyl Mercaptan in Propane. 2.0 Scope 2.1 This method covers the determination of ethyl mercaptan in LP-gas. Limited data (Appendix A) show a precision of 10% of the measured amount. The suggested range of tubes to be used is 0.5 to 25 ppmv. A chromatographic
21、method should be used for more precise, quantitative determination of ethyl mercaptan in propane. CAUTION: This test procedure requires the release of combustible LP-Gas vapors. The user is warned to take proper safety precautions to prevent the accumulation of a combustible mixture and prevent igni
22、tion. This procedure should never be performed in an enclosed building unless a properly designed vapor recovery exhaust hood is provided. Liquid propane evaporates rapidly and can freeze flesh quickly. If any liquid propane is encountered, avoid any skin contact. 1 3.0 Summary of Method 3.1 The sam
23、ple is passed through the detector tube made specifically for the detection of ethyl mercaptan by specially prepared chemicals. The length of stain (or color change) produced in the detector tube when exposed to a measured volume of sample is directly proportional to the amount of ethyl mercaptan pr
24、esent in the sample being tested. A bellows or piston type pump is used to draw a measured volume of sample through the tube at a controlled rate of flow. The length of stain produced is converted to volume by comparison with a calibration scale supplied by the manufacturer with each box of detector
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GPASTD21882014METHODFORTHEDETERMINATIONOFETHYLMERCAPTANINLPGASUSINGLENGTHOFSTAINTUBESPDF

链接地址:http://www.mydoc123.com/p-782334.html