GMW GMW14759-2012 Determination of the Permeability of Elastomers to Liquids or Vapor Issue 2 English.pdf
《GMW GMW14759-2012 Determination of the Permeability of Elastomers to Liquids or Vapor Issue 2 English.pdf》由会员分享,可在线阅读,更多相关《GMW GMW14759-2012 Determination of the Permeability of Elastomers to Liquids or Vapor Issue 2 English.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW14759 Determination of the Permeability of Elastomers to Liquids or Vapor Copyright 2012 General Motors Company All Rights Reserved September 2012 Originating Department: North American Engineering Standards Page 1 of 5 1 Scope Note: Nothing in this
2、 standard supercedes applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. The object of this standard is to determine the permeability of elastomers to liquids, or liquid/vapor mixtures to
3、which they are in contact during service. 1.2 Foreword. Not applicable. 1.3 Applicability. Not applicable. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. ISO 188 2.2 GM Standards/Specifications. None 3 Resources
4、 3.1 Facilities. Not applicable. 3.2 Equipment. 3.2.1 Test Equipment. 3.2.2 Thickness Gauge. The thickness gauge must be capable of indicating the test piece thickness to an accuracy of 0.01 mm. The two contact members consist of domed surfaces of spherical radius 12.5 mm, formed on rods of 10 mm di
5、ameter, between which the test pieces are placed. The force between the contact members shall be 0.85 N 0.03 N. The thickness gauge shall normally consist of one fixed contact member, with the other moving vertically above it, linked to a suitable dial gauge. 3.2.3 Test Apparatus. The test apparatus
6、 shall consist of cylindrical aluminum vessel with internal dimensions of 35 mm 0.5 mm diameter, and 50 mm 0.5 mm height. Around the opening, there shall be a recess, 54 mm diameter and 1.5 mm 0.1 mm deep for the test piece (in case of test piece thickness of 2 mm 0.1 mm). In case of test pieces wit
7、h deviating thickness, supporting discs or spacer rings shall be used. It shall be ensured that the thickness of the test piece is compressed to about 75% of its original height. The test piece shall be clamped between the vessel and the clamp ring, which also has an internal diameter of 35 mm 0.5 m
8、m. The ring shall also have on the side, which is close to the test vessel, a recess 42 mm 0.5 mm diameter and 2 mm 0.5 mm depth for the installation of a support mesh. The support mesh shall consist of suitable gauze, and of such spacing that, while the area in contact with the test piece is at a m
9、inimum, it is sufficiently strong to resist the test piece being displaced from its position by the internal pressure developed within the vessel during the test. The ring shall be clamped to the test vessel by means of six (6) equally spaced screws. Other dimensions are shown in Figure A1, Appendix
10、 A. 3.2.4 Heating oven capable of maintaining the required temperatures within the specified tolerances (e.g., heat oven to ISO 188 Method B). Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without licen
11、se from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14759 Copyright 2012 General Motors Company All Rights Reserved September 2012 Page 2 of 5 3.2.5 Balance with a capacity of 1000 g maximum, and an accuracy 0.01 g. 3.2.6 Test medium shall be specified on the relevant engineering drawings or mater
12、ial specifications. 3.3 Test Vehicle/Test Piece. 3.4 Test Time. Not applicable. 3.4.1 Test Material. 3.4.2 Shape and Size. Unless otherwise specified, the following test pieces shall be used. 3.4.3 Standard Test Piece: Cylindrical discs of diameter 50 mm 1 mm, thickness 2.0 mm 0.1 mm, either molded
13、or cut from sheet. 3.4.4 Test pieces from complete components: where complete components are supplied for test, standard test pieces as described shall be cut from the component. The thickness of the complete component shall be used as thickness of the test piece. 3.4.5 In special cases the complete
14、 component will be used as test piece, here an appropriate test vessel must be provided. 3.4.6 Number of Test Pieces. For initial sample approval and arbitration purposes, at least three (3) test pieces cut from at least two (2) components shall be tested, for routine quality control purposes at lea
15、st one (1) test piece shall be tested. 3.5 Test Required Information. Not applicable. 3.6 Personnel/Skills. Not applicable. 4 Procedure 4.1 Preparation. 4.1.1 Test Sample Preparation. The minimum time period between vulcanization and testing of elastomers shall be 72 h. The test piece shall remain a
16、t a temperature of 23 C 5 C for at least 8 h before testing, and shall be free from strain during this period. 4.1.2 Test Procedure. 4.1.3 Prior to test the thickness of the test piece shall be measured at five (5) positions minimum equally distributed over the test area, at a temperature of +23 C 5
17、 C. The mean thickness shall be calculated from these individual values. 4.1.4 The test vessel shall be completely filled with the test medium in the case of tests to Method A, or to a depth of 40 mm in the case of tests to Method B. The test piece shall then be placed into the recess on top of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW147592012DETERMINATIONOFTHEPERMEABILITYOFELASTOMERSTOLIQUIDSORVAPORISSUE2ENGLISHPDF

链接地址:http://www.mydoc123.com/p-757564.html