GMKOREA EDS-T-5229-2011 High-Pressure Pump for Headlamp-Cleaning System.pdf
《GMKOREA EDS-T-5229-2011 High-Pressure Pump for Headlamp-Cleaning System.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5229-2011 High-Pressure Pump for Headlamp-Cleaning System.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING STANDARDS General Specification SUPERCEDED EDS-T-5229 High-Pressure Pump for Headlamp-Cleaning System This standard may be applied only for current projects. It is Superceded for all future projects and replaced by GMW16619. Copyright 2011 General Motors Company All Rights Reserved Dece
2、mber 2011 Originating Department: GM Korea Engineering Standards Page 1 of 10 Version : 3 1 Introduction Note: Nothing in this standard supersedes applicable laws and regulations. Note: In the event of conflict between the Korean and English language, the Korean language shall take precedence. 1.1 P
3、urpose and Scope. This test specification defines the general test conditions for high - pressure pumps for headlamp cleaning systems. Called shortly “pump“ in the following. Which test specifications are to be applied, as well as material specifications, form, dimensions and surface treatment are t
4、o be noted from the drawing. In addition to this specification, the pump must satisfy the requirement of the countries in the assembly with a high - pressure headlamp cleaning system, in which it is applied. 2 References Note: Only the latest approved standards are applicable unless otherwise specif
5、ied. 2.1 External Standards/Specifications. DIN 30640 DIN 40050 DIN 50049 JIS D5704 MVSS F30 SMS 2983E 2.2 GM Standards/Specifications. EDS-T-7005 EDS-T-7143 EDS-T-7405 GMW3059 2.3 Additional References. None 3 Test Preparation and Evaluation 3.1 Resources. 3.1.1 Calibration. The test facilities and
6、 equipment shall be in good working order and shall have a valid calibration label. 3.1.2 Alternatives. Alternative test facilities and equipment may also be used. However, all measuring variables as specified in this standard shall be determined correctly with respect to their physical definition.
7、3.1.3 Equipment. For the performance of the tests described in this test specification the testing instruments and test means listed in the following are necessary. Unlisted parts are to be serviceably selected. 3.1.3.1 Test arrangement for the performance of the test in condense - water constant cl
8、imate corresponding to EDS-T-7005. 3.1.3.2 Test arrangements for the determining of the chemical constancy corresponding to clause 4.2.1.2 of this test specification. 3.1.3.3 Test arrangement for the determining of the resistance to ozone of elastomers corresponding to EDS-T-7405-1 clause 4. 3.1.3.4
9、 Temperature Cabinet. Temperature cabinet for return - air operation with exhaust, explosion - proof. GM KOREA ENGINEERING STANDARDS EDS-T-5229 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 2 of 10 Version : 3 Work space: Suitable size. Performances: 2 performances = 1
10、00 mm. Range of temperature: (-40) E . +100 E . continuously adjustable (Program control is recommended) Temperature constancy: 2K spatially and temporally Rate of acceleration of temperature for the empty tempering chamber: 1 K/min (recommended value). 3.1.3.5 Voltage Stabilizer. Range of voltage:
11、0 . 15 V continuously adjustable Range of current: 0 . 100 A, current limiting continuously adjustable 3.1.3.6 Voltage Measuring Instrument. Voltage measuring instrument for example moving - coil instrument of the grade 0.5 with corresponding compensating resistance. 3.1.3.7 Current Measuring Instru
12、ment. Current measuring instrument for example moving - coil instrument of the grade 0.5 with corresponding shunt. 3.1.3.8 Time Switch with Counting Device. The time switch with counting device is an instrument with which the pump is operated after readjusted operating and spacing time over the tota
13、l number of cycles. The time switch with counting device should be able to switch automatically off after reaching a presupposed number of cycles. Input and output voltage: 0 15 V Rise time of output voltage: 0.1 second Decay time of output voltage: 0.1 second Interval times: Variable Continuously f
14、rom 1 s to 30 seconds Pause interval variable: Continuously from 1 s to 30 seconds Accuracy of reading: 0.5 second Counting device: Frequency 0.1 Hz Counting volume 2,000 impulses 3.1.3.9 Over - Pressure Measuring Instrument. Over - pressure measuring instrument for example sensitive pressure gauge,
15、 grade 0.6, with an indicating range of 0 ) 400 KPa and a scale division of 2 KPa. Electro-dynamically working data - receiver and electric indicating instruments are like - wise instertable, so far available. 3.1.3.10 Gauge Glasses. Content 10-6m3 Scale Division 10-6m3 Number 100 1 4 1,000 10 2 2,0
16、00 20 1 3.1.3.11 Cable. 3.1.3.11.1 Cable of suitable length, composed of twin, snaked, electric leads with a cross section of 1.5 mm2 for the electrical connection of the time switch with the pumps. The combining elements at the ends of the electric leads (for example, cable eyes, banana plug) must
17、be soldered with the electric leads. 3.1.3.11.2 Cable of suitable length, composed of an electric lead with a cross section of 16 mm2 for the electrical connection of the time switch with the voltage stabilizer. The combining elements at the ends of the electric lead (for example, cable eyes) must b
18、e soldered with the electric lead. This cable is necessary only at the endurance test of the pumps according to clause 4.2.8. 3.1.3.12 Oscillating Table with Oscillator. GM KOREA ENGINEERING STANDARDS EDS-T-5229 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 3 of 10 Ver
19、sion : 3 The oscillating table with oscillator, called shortly oscillating table in the following, is a device with which oscillations are executed respectively in a vertical direction and 2 horizontal directions standing vertically one after another, temporally independent of each other. The oscill
20、ator must be so designed that the oscillating table executes oscillations corresponding to the following data. Frequency: 10 Hz . 50 Hz sine, continuously adjustable Accuracy of reading 0.5 Hz Frequency drift: (6030) sec/octave Oscillating amplitude: 0.2 mm . 0.7 mm adjustable Accuracy of reading: 0
21、.02 mm 3.1.3.13 Testing Medium. Water (tap water) or a mixture of 50 vol. % water and 50 Vol % isopropanol is used as testing medium, as described in the individual testing points. The quantity of the testing medium is to be so selected that the pump is constantly filled with fluid during the test.
22、3.1.3.14 Testing Nozzle. For the function test corresponding to clauses 4.2.5.3 and 4.2.5.4 of this test specification, a testing nozzle is to be used. The nozzle should make possible reproduce able measurements of the pump parameters. The geometric dimension sizes of the testing nozzle are evident
23、from Appendix 1. For the endurance test production nozzles can be used. 3.1.3.15 Regulating Valve. The regulating valve forms a unit with the nozzle. The opening pressure of the regulating valve should be (12515) KPa, the closing pressure 60 KPa. For the test, released production parts are to be use
24、d. 3.1.3.16 Timing Relay. The timing relay limits the duration of connection of the pump to (0.530.03) seconds per manipulation. For the test, released production parts are to be used. 3.1.3.17 Hose Garniture. The hose garniture is composed of braided hoses which serve for the connection of the sing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST52292011HIGHPRESSUREPUMPFORHEADLAMPCLEANINGSYSTEMPDF

链接地址:http://www.mydoc123.com/p-757124.html