《GME 60292-2000 Determination of Colour Fastness and Resistance to Aritificial Light (English German Include Appendix A thru C).pdf》由会员分享,可在线阅读,更多相关《GME 60292-2000 Determination of Colour Fastness and Resistance to Aritificial Light (English German Include Appendix A thru C).pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Test MethodMaterialsGME 60292Determination of Colour Fastnessand Resistance to Aritificial LightBeurteilung der Lichtechtheit undder Lichtbestndigkeit1 Scope 1 ZweckThis Test Method shall be used for determining thecolour fastness to artificial light of dyes, prints, paintson organic materials of th
2、e interior trim (textiles, films,artificial leather, plastics, cardboard, wood etc.) by ex-posure to artificial light representative of natural day-light and to the simultaneous action of heat. This TestMethod is valid to determine the colour fastness whenusing a xenon arc lamp source of light.Die P
3、rfung dient zur Ermittlung der Lichtechtheit vonFrbungen, Drucken und Lackierungen von organi-schen Werkstoffen der Innenaustattung (Textilien,Folien, Kunstleder, Kunststoffen, Pappen, Holz o.)unter Einwirkung von knstlichem Tageslicht undgleichzeitiger Hitzeeinwirkung. Dieses Prfverfahrengilt fr di
4、e Lichtechtheitsbestimmung bei Verwendungvon gefiltertem Xenonbogenlicht.Note: Nothing in the specification, however, super-sedes applicable laws and regulations unless a spe-cific exemption has been obtained.Hinweis: Falls keine Ausnahmen vereinbart wurden,darf die Vorschrift keine anzuwendenden Ge
5、setzeund Regelungen auer Kraft setzen.Note: In the event of a conflict between the Englishand the German language, the German languageshall take precedence.Hinweis: Im Falle von Unstimmigkeiten zwischendem englischen und dem deutschen Text, ist derdeutsche Text ausschlaggebend.1.1 Definition. Colour
6、 fastness to artificial light is ameasure of the resistance of colourants (dyes, pig-ments etc.) of any type of organic materials in anyprocessing state to the effects of light and heat.1.1 Begriff. Unter Lichtechtheit versteht man die Wi-derstandsfhigkeit der Farbe von organischen Werk-stoffen jede
7、r Art und in allen Verarbeitungszustndengegen Einwirkung von Licht und Wrme.2 References 2 ReferenzenNote: Only the latest approved standards are appli-cable unless otherwise specified.Hinweis: Wenn nicht anders angegeben, ist jeweilsdie neueste Fassung der angegebenen Referenz gl-tig.2.1 Normative.
8、 2.1 Normative.ISO 105-A02 ISO 105-B01 ISO 105-B02 ISO 4892-1 DIN 752022.2 GM. None. 2.2 GM. Keine.2.3 Additional. CIE Technical Report No. 85, Edi-tion 19892.3 Zustzliche. CIE Technical Report No. 85, Edi-tion 1989 Copyright 2000 General Motors Corporation All Rights ReservedOriginating Department:
9、 GME Specification CenterAugust 2000 Page 1 of 13GME 60292 GM EUROPE ENGINEERING STANDARDS3 Test Equipment 3 Prfausrstung3.1 Light Source and Filter System. The lightsource is equipped with one or more xenon arc lampsas the source of radiation. The radiation shall befiltered for determination of the
10、 colour fastness andthe aging of materials for vehicle interior resulting ofexposition to light by high temperatures.Therefore anoptical filter system is used. Applicable are absorbingfilters or a combination of absorbing and reflectingfilters.3.1 Optische Strahlenquelle und Filtersystem. Alsoptisch
11、e Strahlenquelle werden eine oder mehrereXenonbogenstrahler verwendet. Fr die Bestim-mung der Farbechtheit und des Alterungsverhaltensvon Werkstoffen der Kraftfahrzeuginnenausstattunggegen Licht bei hohen Temperaturen mu die Strah-lung gefiltert werden. Hierzu werden Systeme vonoptischen Strahlungsf
12、iltern verwendet. Eingesetztwerden sowohl Absorptionsfilter als auch Kombinati-onen von Absorptions- und Reflexionsfiltern.Independently of the type of filtration compliance withthe conditions listed in Table 1 is required for thespectral distribution of the radiation, which is existingin the plane
13、of the test piece. The values resultfrom the spectral distribution of the global radiationaccording to CIE Technical Report No. 85, Table 4(edition 1989) and the transmission of window glassof 4 mm thickness.Unabhngig von der Art der Filterung sind hinsicht-lich der spektralen Verteilung der auf der
14、 Probekr-perebene vorliegenden Strahlungen die in Tabelle 1genannten Bedingungen zu erfllen. Die Werte erge-ben sich aus der Spektralverteilung der Globalstrah-lung nach CIE Technischer Bericht Nr. 85, Tabelle 4(Ausgabe 1989) und der spektralen Transmission von4 mm dickem Fensterglas.Table 1: Spectr
15、al Irradiation Intensity Tabelle 1: Spektrale BeleuchtungsstrkeWave Length /WellenlngenmRelative Irradation Intensity(Note 1)/Relative Bestrahlungs-strke(Note 1)%below 290 /unter 2900below 300 0.05280.320 0.1320.360 3 0.85360.400 5.7 +2.0 / -1.3400.520 32.2 +3.0 / -5.0520.640 30.0 3.0640.800 29.1 6.
16、0to 800 /bis 800100Note 1: referred to the irradiation intensity in the wave length rangeup to 800 nmNote 1: bezogen auf die Bestrahlungsstrke im Wellenlngenbe-reich bis 800 nmThe radiation power shall be chosen such, that theconditions to Table 2 are met.Die Strahlungsleistung ist so zu whlen, da d
17、ie Be-dingungen nach Tabelle 2 erfllt werden. Copyright 2000 General Motors Corporation All Rights ReservedPage 2 of 13 August 2000GM EUROPE ENGINEERING STANDARDS GME 60292The variation of the irradiation intensity over the areacovered by the test pieces and references of thecolour fastness standard
18、 shall not exceed 10 % ofthe mean. The optical systems of radiation filters tobe used are described in Appendix A.Die Abweichung der Bestrahlungsstrke vom Mittel-wert ber die ganze von den Proben und Typfrbun-gen des Lichtechtheitsmastabes eingenommeneFlche darf 10 % nicht berschreiten. Die anzu-wen
19、denden optischen Systeme von Strahlungsfilternsind in Anhang A beschrieben.Remark: Due to aging of Xenon arc fading lamps andoptical filters the radiation function and the irradiationintensity is changing with the operation time. The ra-diation function and the irradiation intensity will stayconform
20、 if the lamps and the filters are replaced ac-cording to manufacturer recommendation. The irradi-ation intensity may be also kept constant by a control.Bemerkung: Durch Alterung der Xenonbogenlam-pen und der optischen Filter verndert sich whrendder Betriebsdauer die Strahlungsfunktion und dieBestrah
21、lungsstrke. Durch Erneuerung der Lam-pen und Filter - entsprechend den Angaben derGertehersteller - kann die Strahlungsfunktion unddie Bestrahlungsstrke eingehalten werden. Die Be-strahlungsstrke kann auch durch Regeln konstantgehalten werden.3.1.1 Exposure Apparatus. The used exposure ap-paratus sh
22、all consist of a climatic chamber made fromcorrosion resistance material, which contains the lightsource, the filter system and the frame holder for thetest piece. The supplier of the exposure apparatusshall insure, that the exposure apparatus fulfills theconditions of Table 1 and Table 2.3.1.1 Expo
23、sitionsgert. Das verwendete Expositi-onsgert soll im wesentlichen aus einer klimatisier-ten Prfkammer aus korrosionsbestndigem Werk-stoff, in der sich die optische Strahlenquelle mit Filter-system und die Halterungen fr die Probekrper be-finden, bestehen. Der Gertehersteller mu bei Liefe-rung eines
24、Expositionsgertes nach dieser Vorschriftsicherstellen, da die in Tabelle 1 und Tabelle 2 ge-stellten Bedingungen erfllt werden.3.2 Black-standard Thermometer. A black-stan-dard thermometer is used to determine the tempera-ture in the exposure apparatus at the place of the testpiece. This black-stand
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GME602922000DETERMINATIONOFCOLOURFASTNESSANDRESISTANCETOARITIFICIALLIGHTENGLISHGERMANINCLUDEAPPENDIXATHRUCPDF

链接地址:http://www.mydoc123.com/p-754942.html