FORD FLTM BZ 156-01-2011 DETERMINATION OF FORMALDEHYDE ALDEHYDE AND KETONE EMISSIONS FROM NON METALLIC COMPONENTS PARTS AND MATERIALS IN THE VEHICLE INTERIOR《对非金属部件 零件和车辆内饰材料中甲醛 乙醛.pdf
《FORD FLTM BZ 156-01-2011 DETERMINATION OF FORMALDEHYDE ALDEHYDE AND KETONE EMISSIONS FROM NON METALLIC COMPONENTS PARTS AND MATERIALS IN THE VEHICLE INTERIOR《对非金属部件 零件和车辆内饰材料中甲醛 乙醛.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BZ 156-01-2011 DETERMINATION OF FORMALDEHYDE ALDEHYDE AND KETONE EMISSIONS FROM NON METALLIC COMPONENTS PARTS AND MATERIALS IN THE VEHICLE INTERIOR《对非金属部件 零件和车辆内饰材料中甲醛 乙醛.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BZ 156-01 Date Action Revisions Rev. 1 2011 07 14 Revised S.Riewer, FoE 2009 01 23 Activated S.Riewer, FoE Controlled document at www.MATS Copyright 2011, Ford Global Technologies, LLC Page 1 of 9 DETERMINATION OF FORMALDEHYDE, ALDEHYDE, AND KETONE EMISSIONS FROM NON MET
2、ALLIC COMPONENTS, PARTS AND MATERIALS IN THE VEHICLE INTERIOR Application The test method describes the measurement procedure for determining formaldehyde, aldehyde, and ketone emissions from components, parts and materials in the interior of vehicles. The procedure is used for testing the distribut
3、ion of aldehyde and ketone emissions between components. Subject to certain restrictions, it can also be used for material development and for acceptance testing. As to its technical content, Part A is for determining formaldehyde content in accordance with the modified bottle method and conforms to
4、 VDA 275 (German Automotive Association). Part B is to analyze aldehyde and ketone emissions by high performance liquid chromatography (HPLC). The bottle method was developed for the purpose of determining the formaldehyde emission from woven textiles and untreated particle boards. It has subsequent
5、ly been applied in different variants for the testing of other materials. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5% relative humidity for not less than 24 hours prior to testing and teste
6、d under the same conditions unless otherwise specified. PART A. PHOTOMETRIC DETERMINATION OF FORMALDEHYDE EMISSION FROM NON METALLIC COMPONENTS, PARTS AND MATERIALS IN VEHICLE INTERIORS Materials Required Acetyl acetone, p.a. Sodium thiosulphate (c(Na2S2O3)= 0.1 mol/L), p.a. Ammonium acetate, p.a. S
7、odium hydroxide (c(NaOH)= 1 mol/L), p.a. Formaldehyde solution (35-40%), p.a. Starch, p.a. Lodine soultion (C(I2)= 0.05 mol/L), p.a. Sulphuric acid (c(H2SO4)= 1 mol/L), p.a. Distilled water Note: Commercially available ready-mixed solutions can be used if the same results are achieved. FORD LABORATO
8、RY TEST METHOD BZ 156-01 Controlled document at www.MATS Copyright 2011, Ford Global Technologies, LLC Page 2 of 9 Apparatus Required - Analytical balance with a 1 mg scale - Heating chamber with air circulation - Spectrophotometer test apparatus - Polyethylene bottles with a volume of 1 litre with
9、a lid (see fig. 1) - Hook made of stainless steel with seals, positioned inside the lid of the test bottle - Precision burette, 50 mL, calibrated at 20 C - Graduated flasks, 1000 mL, calibrated at 20 C - Graduated flasks, 100 mL, calibrated at 20 C - Pipette, 5 mL, calibrated at 20 C - Pipette, 10 m
10、L, calibrated at 20 C - Pipette, 15 mL, calibrated at 20 C Method 1. Number of tests: The determination shall be performed five times. The test pieces shall be evenly distributed over the width of the component and taken at suitable, representative points. The size of the test pieces shall be 40 mm
11、x 100 mm x subject material thickness. At least 6 test pieces shall be taken from each component. Five of these are for the formaldehyde test and one for determining the moisture content. 2. Determination of moisture content The moisture content is determined in accordance with BS EN 322 Wood-based
12、sheets - Moisture quotient -Testing). 3. Determination of formaldehyde emission One or 2 holes are positioned 10 mm from the upper edge of the test piece to permit them to be hung with the help of hooks. The test piece is weighed prior to the start of the analysis on an analytical balance with an ac
13、curacy of 0.01 g. Using a pipette, 50 mL of distilled water are added to each of the polyethylene bottles. After placing the test pieces on the hooks (see fig. 1), the vessel is sealed and kept for at least 3 h in the heating cabinet at a constant temperature of 60 C. At the end of the test period,
14、the vessels are removed from the heating cabinet. After having stood for 60 min at room temperature, the test pieces are removed from the test bottle. FORD LABORATORY TEST METHOD BZ 156-01 Controlled document at www.MATS Copyright 2011, Ford Global Technologies, LLC Page 3 of 9 Figure 1 4. Blind tes
15、t. This test is performed in parallel without test pieces. 5. Determination of formaldehyde concentration in the aqueous solution The determination of the formaldehyde level in the aqueous solution is performed photometrically by the acetyl acetone method. 5.1 Principle The determination is based on
16、 the Hantzsch reaction in which formaldehyde in aqueous solution reacts with ammonium ions and acetyl acetone to form diacetyl dihydrolutidin (DDL). DDL has an absorption maximum at 412 nm. The reaction is specific to formaldehyde. CH3COCH2COCH3 + HCHO NH4+ -3 H2O-H+ NOHCH3CH3CH3OCH3+DDL 5.2 Reagent
17、s Acetyl acetone solution 4 mL of acetyl acetone are poured into a 1000 mL graduated flask, which is then topped up with water to the 1000 mL mark. The solution is kept under a gas-tight seal and protected from the light for up to 4 weeks. Ammonium acetate solution 200 g of ammonium acetate are weig
18、hed into a 1000 mL graduated flask, dissolved in distilled water and topped up to 1000 mL. FORD LABORATORY TEST METHOD BZ 156-01 Controlled document at www.MATS Copyright 2011, Ford Global Technologies, LLC Page 4 of 9 5.3 Method 10 mL of the aqueous solution (para. 3) are taken up with a pipette an
19、d mixed in a 50 mL bottle with 10 mL of acetyl acetone solution and 10 mL of ammonium acetate solution. The bottle is closed, shaken and heated for 15 min in a water bath at a temperature of +40 C 1 C. The by now greenish-yellow solution shall then be left in an area protected from the light at a te
20、mperature of 23 C 2 C for 1 h. The concentration of this solution is determined at a wavelength of 412 nm against distilled water by means of a spectrophotometer. A blind value is determined in parallel with distilled water, and account is taken of the blind test in the calculation. Note: After each
21、 determination, the polyethylene bottles shall be cleaned in a laboratory washing machine. If this is not sufficient, it is recommended that the bottles are heated to 70 C in a heating chamber for approx. 16 h. 6. Calibration curve The calibration curve is produced by means of a formaldehyde standar
22、d solution, the concentration of which is determined by iodometric titration. The calibration curve shall be verified at least once a week. 6.1 Formaldehyde Standard Solutions Reagent Solutions: lodine C(I2) = 0.05 mol/L Sodium thiosulphate c(Na2S2O3) = 0,1 mol/L Sodium hydroxide c(NaOH) = 1 mol/L S
23、ulphuric acid c(H2SO4) = 1 mol/L Starch solution, 1 % m/m The concentration of the solution shall be verified before use. Approx. 1 g of formaldehyde solution (concentration 35 to 40 %) is poured into a 1000 mL graduated flask, which is then filled with distilled water up to the mark. The precise fo
24、rmaldehyde concentration is determined as follows: 20 mL of the formaldehyde solution are mixed with 25 mL of iodine solution and 10 mL of sodium hydroxide. This mixture shall be left to stand protected from the light for 15 min, after which 15 mL of sulphuric acid are added. Any surplus iodine is r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ156012011DETERMINATIONOFFORMALDEHYDEALDEHYDEANDKETONEEMISSIONSFROMNONMETALLICCOMPONENTSPARTSANDMATERIALSINTHEVEHICLEINTERIOR

链接地址:http://www.mydoc123.com/p-747709.html