1、 FORD LABORATORY TEST METHOD BV 116-03 Date Action Revisions 2001 06 26 Activated A. Lin Printed copies are uncontrolled Page 1 of 5 Copyright 2001, Ford Global Technologies, Inc. WASH RESISTANCE TEST FOR SEALERS AND ADHESIVES Application This method is used to evaluate the wash resistance of uncure
2、d sealers and adhesives under conditions typical of the cleaner stage of the pre-treatment system. Apparatus Required High Pressure Washer A washer capable of pumping water between 10 and 60 +/- 3 C and maintaining a minimum pressure of 13,800 +/- 700 kPa (2000 +/- 100 psi) at the outlet nozzle when
3、 used in conjunction with the type of nozzle specified. Pressure Gauge A gauge capable of measuring the specified pressure with a precision of +/- 2%. Spray Nozzle A 40040 flat spray nozzle (i.e. 40 wide angle flat spray pattern and 0.040 inch (1.016 mm) orifice) that could be connected to the outle
4、t of the pump. Analytical Balance Minimum precision of +/- 0.01 g. Drying Oven An ASTM E 145 oven capable of maintaining 130 C. Ruler Camera Materials Required Substrate Test Panels Sealer/Adhesive Prelube Type and quantity per material specification or other relevant engineering documents. FORD LAB
5、ORATORY TEST METHOD BV 116-03 Page 2 of 5 Copyright 2001, Ford Global Technologies, Inc. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testi
6、ng and tested under the same conditions unless otherwise specified. Procedure 1. Measure and record the weight of the lubricated substrate panel. This value is the Initial Lubricated Panel Weight, A. 2. Prepare a draw down sealer/adhesive bead of 30 mm x 200 mm x 1.5 mm on the panel. 3. Measure and
7、record the total weight of the lubricated panel and the bead. This value is the Total Weight Before Pressure Wash, B. 4. Connect the nozzle to the pressure washer outlet (use water temperature and pressure as specified in relevant engineering documents). Spray water at the sealer/adhesive bead using
8、 either Method A (Indirect Impingement) or Method B (Direct Impingement) as specified. Method A: Indirect Impingement Spray water at the panel such that the water fan is 45 to the area that is 25.4 mm from the bottom edge of the bead, as shown in Figure 1. The water fan should be 20.3 cm wide at poi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV11632001WASHRESISTANCETESTFORSEALERSANDADHESIVESPDF

链接地址:http://www.mydoc123.com/p-747620.html