FORD FLTM BL 106-01-2010 STAGNANT COOLANT TEST FOR ALUMINUM AND FLUORINE AND ITS EFFECT ON ALUMINUM CORROSION UNDER HEAT REJECTING CONDITIONS《铝和氟冷却液可溶性滞流试验》.pdf
《FORD FLTM BL 106-01-2010 STAGNANT COOLANT TEST FOR ALUMINUM AND FLUORINE AND ITS EFFECT ON ALUMINUM CORROSION UNDER HEAT REJECTING CONDITIONS《铝和氟冷却液可溶性滞流试验》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BL 106-01-2010 STAGNANT COOLANT TEST FOR ALUMINUM AND FLUORINE AND ITS EFFECT ON ALUMINUM CORROSION UNDER HEAT REJECTING CONDITIONS《铝和氟冷却液可溶性滞流试验》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHODBL 106-01 Date Action Revisions 2010 08 10 Revised See Summary of Revisions A. Reaume, NA 2010 03 16 Activated A. Reaume, NA Printed copies are uncontrolled Copyright 2010, Ford Global Technologies, LLC Page 1 of 2 STAGNANT COOLANT TEST FOR ALUMINUM AND FLUORINE AND ITS E
2、FFECT ON ALUMINUM CORROSION UNDER HEAT REJECTING CONDITIONS Application This method is used to 1) prepare a soluble solution of aluminum and fluorine in engine coolant under stagnant conditions and 2) measure the effect of this solution on the corrosion of aluminum under heat rejecting conditions us
3、ing ASTM D4340. Equipment Required 1. Oven: capable of 90C, holding automotive heat exchangers and vented to the outside 2. Rubber plugs: size and number depends on the heat exchanger (all openings to be plugged) 3. Aluminum foil pieces 4. Screw clamps: size and number depends on the heat exchanger
4、(intent is to keep the plugs in place 5. Bin: large enough to hold the heat exchangers, to capture any lost coolant 6. Glass graduated cylinder with glass or Teflon stopper: 1000 ml 7. Refractometer 8. Glass stirring rod 9. Fresh/unused coolant concentrate 10. Aluminum engine cooling system componen
5、t with the exception of the engine and water pump. Example is the heat exchanger with known internal fluxing as part of the controlled atmosphere brazing process (e.g. Nocolok potassiumaluminofluorinate flux). Note: More than 1 heat exchanger may be required for stagnation testing because the volume
6、 of coolant required for post-stagnation testing is 1.25L) - Report of the internal volume of the heat exchanger - Report of the internal surface area of the heat exchanger 11. De-ionized or distilled water 12. Plastic samples bottles: 2 X 250ml, and 1 X 1L 13. Full face shield, gloves, and other re
7、quired safety equipment 14. Equipment required to perform ASTM D4340 FORD LABORATORY TEST METHODBL-106-01 Printed copies are uncontrolled Copyright 2010, Ford Global Technologies, LLC Page 2 of 2 Procedure 1. Mix 500 ml of fresh coolant concentrate with 500 ml de-ionized or distilled water in gradua
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBL106012010STAGNANTCOOLANTTESTFORALUMINUMANDFLUORINEANDITSEFFECTONALUMINUMCORROSIONUNDERHEATREJECTINGCONDITIONS

链接地址:http://www.mydoc123.com/p-747152.html