《FORD FLTM BI 159-01-2001 DETERMINATION OF THE RESISTANCE TO FLOTATION OF CONVENTIONAL METALLIC PAINTS (Replaces FLTM EU-BI 059-01)《传统金属油漆的耐浮性能的测定 替代FLTM EU-BI 059-01[替代 FORD FLTM E.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 159-01-2001 DETERMINATION OF THE RESISTANCE TO FLOTATION OF CONVENTIONAL METALLIC PAINTS (Replaces FLTM EU-BI 059-01)《传统金属油漆的耐浮性能的测定 替代FLTM EU-BI 059-01[替代 FORD FLTM E.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 159-01 Date Action Revisions 2001 03 20 Revised Editorial no technical change A. Cockman 1992 04 06 Printed copies are uncontrolled Page 1 of 5 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF THE RESISTANCE TO FLOTATION OF CONVENTIONAL METALLIC PAINTS
2、Application This method is used to determine the resistance to flotation of conventional metallic paints. Apparatus Required 1. Automatic Spray Equipment - Spraymation Model 9148 a. Spraygun to be De Vilbiss ABG Series 501 Gun, Needle and Tip - AV15EX with No. 30 air cap, or suitable equivalent. b.
3、Air pressure - 450 kN/m2 c. Number of coats - 3 d. Flash-off between coats - 2 minutes 2. Spraybooth - Air Conditioned a. Airflow over panel rack must be 45-60 m/min b. Booth temperature must be 24 +/- 2 C c. Relative Humidity must be maintained at 45 - 64 % 3. Laboratory forced air oven capable of
4、maintaining a constant temperature of 180 +/- 1 C. 4. Macbeth Color Matching Booth, or equivalent, with North Sky Daylight according to FLTM BI 109-01. 5. Thickness gauge - Permascope with constant pressure probe or approved alternative. 6. Test panels: Steel body skin panels with an Ra of 0.9 - 1.8
5、 microns. Test panel size to be 300 mm x 335 mm minimum. FORD LABORATORY TEST METHOD BI 159-01 Page 2 of 5 Copyright 2001, Ford Global Technologies, Inc. Preparation of Test Panels 1. Prime, wet sand and dry test panels as described in FLTM BI 103-02. Mask one (1) edge of test panel to allow enamel
6、film thickness to be measured. 2. Reduce enamel under test to the recommended test viscosity using xylol as the paint solvent. 3. Establish Standard Spraymation settings such as fluid flow, lap distance, etc., such that the application of three (3) coats of enamel at an enamel dry film thickness of
7、45 - 50 microns meets all paint appearance requirements. These settings will then be the standard settings for the paint under test. The flash-off after the final coat should be five (5) minutes with the panel kept in a horizontal position. Note: It may be necessary to alter slightly the standard se
8、ttings to achieve paint appearance requirements if the evaluation is carried out over more than one (1) day. 4. Test Variations in Spraymation Settings Setting 1 Setting 2 Setting 3 a. Fluid Flow FF1 FF2 FF3 b. Gun to panel distance GD1 GD2 GD3 c. Traverse speed TS1 TS2 TS3 Setting No. 1 is the stan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI159012001DETERMINATIONOFTHERESISTANCETOFLOTATIONOFCONVENTIONALMETALLICPAINTSREPLACESFLTMEUBI05901

链接地址:http://www.mydoc123.com/p-747051.html