FORD FLTM BI 120-2-2001 DETERMINATION OF THROWING POWER OF ELECTROCOATING MATERIALS (Replaces FLTM BI 020-02 A FLTM BI 020-02 C FLTM EU-BI 020-02 A FLTM EU-BI 020-02 C).pdf
《FORD FLTM BI 120-2-2001 DETERMINATION OF THROWING POWER OF ELECTROCOATING MATERIALS (Replaces FLTM BI 020-02 A FLTM BI 020-02 C FLTM EU-BI 020-02 A FLTM EU-BI 020-02 C).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 120-2-2001 DETERMINATION OF THROWING POWER OF ELECTROCOATING MATERIALS (Replaces FLTM BI 020-02 A FLTM BI 020-02 C FLTM EU-BI 020-02 A FLTM EU-BI 020-02 C).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 120-02 Date Action Revisions 2001 03 19 Revised Editorial no technical change A. Cockman 1991 05 28 Printed copies are uncontrolled Page 1 of 5 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF “THROWING POWER“ OF ELECTROCOATING MATERIALS Application Thi
2、s test is used to determine the ability of electrocoating materials to extend a protective coating into recessed areas. Apparatus and Materials Required Power Source Zero to 1000 Volt DC Zero to 10 Amp. Note 1: The maximum peak to peak value of the primary AC ripple must not exceed 10 % of the indic
3、ated coating voltage. Note 2: Equipment having a lower voltage range may be used providing voltages higher than the maximum required by the materials are available. Coating Tank Cylindrical non-conducting, acid resistant container, e.g. glass, having a minimum internal diameter of approximately 150
4、mm and a height of approximately 320 mm. Laboratory Stirrer (Acid Resistant) Zero to 700 rpm, electrically insulated shaft of suitable design to give adequate circulation. Throwing Power Box (See Drawing) This is an open ended box made using two 105 x 300 mm test panels and two insulated acid resist
5、ant strips 10 x 4 x 300 mm. The strips are inserted between the edges of the panels which are then fixed together using waterproof insulating tape or clips to prevent deposition beneath the strips. The cathode holder shall have dimensions giving satisfactory electrical contact with both test panels.
6、 FORD LABORATORY TEST METHOD BI 120-02 Page 2 of 5 Copyright 2001, Ford Global Technologies, Inc. Test Panels and Anode Ford Quality Control approved test panels UMA0018005 - (phosphated) or as specified in the relevant material specification. The two panels are electrically connected by a conductin
7、g bridge using crocodile clips. Phosphate coated panels must be dried at 105 C (metal temperature) for 3 minutes minimum, stored in a desiccator up to 24 hours or used within 1 hour. Note: Alternative panels may be used for special test purposes, e.g. Plant phosphated panels, after notification and
8、agreement with Quality Control. The type of phosphate and coating weight used must be stated. This coating must be in accordance with WSK-M3P1-C unless otherwise stated in the material specification. Thermostat Capable of controlling bath temperature to +/- 2 C. Note: A coolant system is necessary t
9、o maintain the bath at 20 C or as currently used in production. The cooling tube must be acid resistant. Mechanical Convection Oven Capable of maintaining temperatures up to 200 C within +/- 2 C. Low Conductivity Water Conductivity must not be greater than 10 uS/cm at 20 C. Electrode Holder (Insulat
10、ing Material) To support cathode (test box) and anode panel (105 x 300 mm) parallel to each other and 50 mm apart. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not les
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI12022001DETERMINATIONOFTHROWINGPOWEROFELECTROCOATINGMATERIALSREPLACESFLTMBI02002AFLTMBI02002CFLTMEUBI02002AFLTMEUBI02002CPDF

链接地址:http://www.mydoc123.com/p-747018.html