1、 FORD LABORATORY TEST METHOD AI 103-02 Date Action Revisions 2000 08 07 Editorial no technical change A. Cockman 1995 02 14 Printed copies are uncontrolled Page 1 of 4 Copyright 2000 , Ford Global Technologies, Inc. UVA RETENTION IN CLEARCOATS Application This test method determines the amount of ul
2、traviolet light absorbers (UVA) in clearcoat enamels. UVAs are lost as a function of weathering and can be monitored as a function of exp osure time in a weatherometer or Florida. This information provides a way to evaluate the durability of coatings based on the rate of UVA loss, and should be used
3、 as a comparison tool for modifications to a coating and across coating families. Required Test Equipment Quartz Slides - 10 mm wide to fit standard UV - VIS spectrophotometer sample compartment, approximately 37 mm long X 1 - 2 mm thick Glass Capillary Tubes - for coating quartz slides with clearco
4、at Laboratory Oven - capable of curing coating Soft Foam Pad - for cleaning exposure panels Compressed Air Source - for drying panels after washing Single Edged Razor Blades - for scraping clearcoat off of panels Volumetric Flasks - 25 mL with ground glass joints Glass Stoppers - to fit 25 mL volume
5、tric flask Analytical Balance - capable of measuring to 0.001g Pipettes - 1 - 2 mL disposable glass Filtering Media - Kimwipes EX - L from Kimberly - Clark or equivalent UV Quartz Cuvettes - 10 mm X 10 mm UV-VIS Spectrophotometer System - capable of measuring 250 - 400 nm Materials and Solutions Req
6、uired Methylene Chloride - certified ACS grade or equivalent Mild Soap Solution - for washing Florida panels FORD LABORATORY TEST METHOD AI 103-02 Page 2 of 4 Copyright 2000, Ford Global Technologies, Inc. Method A: - UVA Retention of Clearcoats on Quartz Slides This method is used for determining U
7、VA retention of clearcoat films on quartz slides after weathering. A sufficient number of quartz slides shall be prepared for weathering to satisfy the applicable Engineering Specification. I. Preparation of Coatings on Quartz Slides 1. Collect a UV baseline on the quartz slides prior to coating wit
8、h clearcoat. 2. Using a capillary tube, coat a quartz slide with c learcoat paint containing a UVA. 3. Allow the paint solvent to evaporate. NOTE: The quartz slide must be anchored in the sample compartment in the same orientation each time a measurement is made in order to get consistent results. 4
9、. Observe the UV spectr um of the clearcoat from 450nm to 250nm. a. If the maximum absorbance is in the range specified in the relevant material specification, cure the clearcoat paint on the quartz slide using the recommended temperature and time or as indicated by the applicabl e engineering speci
10、fication. b. If the maximum absorbance is not in the desired range specified in the relevant material specification, remove the uncured clearcoat from the quartz slide by rinsing with methylene chloride. Repeat steps 2 - 4 until the abso rbance is in the recommended range. 5. Observe the UV spectrum
11、 of the clearcoat after cure. a. If the maximum absorbance is still in the desired range, obtain a UV spectrum of the clearcoat from 450 to 250nm before weathering has occurred. b. If the maximu m absorbance has dropped below the minimum of the desired range, the UVA present in the clearcoat is vola
12、tile. The coating and curing process must be repeated until a maximum absorbance in the desired range after cure has been obtained. It is possible to e stimate the degree of volatility from the first preparation and compensate accordingly. 6. Record the absorbance of the baseline. (It may be zero.)
13、7. Record both the wavelen gth and the absorbance of all the maxima observed. 8. If necessary, subtract the baseline absorbance from the absorbance of the maxima to get the corrected absorbance values. These will be called the “time 0“ values. It is necessary to record a “time 0“ sp ectrum for each
14、sample. FORD LABORATORY TEST METHOD AI 103-02 Page 3 of 4 Copyright 2000, Ford Global Technologies, Inc. II. Monitoring UV Retained 1. Remove the quartz slides from exposure at intervals indicated by the applicable Engineering Specification or more frequently as suggested by the ongoing results. Rec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAI103022000UVARETENTIONINCLEARCOATS 清漆 长波 紫外线 UVA 保持 性能 PDF

链接地址:http://www.mydoc123.com/p-746724.html