FORD ESE-M2D286-A-2009 HOSE REINFORCED RUBBER - FUEL LINE TO BE USED WITH FORD WSS-M99P1111-A 《燃料管用增强型橡胶软管 与标准FORD WSS-M99P1111-A一起使用 》.pdf
《FORD ESE-M2D286-A-2009 HOSE REINFORCED RUBBER - FUEL LINE TO BE USED WITH FORD WSS-M99P1111-A 《燃料管用增强型橡胶软管 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD ESE-M2D286-A-2009 HOSE REINFORCED RUBBER - FUEL LINE TO BE USED WITH FORD WSS-M99P1111-A 《燃料管用增强型橡胶软管 与标准FORD WSS-M99P1111-A一起使用 》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2009 08 21 N-STATUS No Replacement Named C. Mracna, NA 2004 09 23 Revised Inserted 3.0; Deleted 3.13, 3.14 & 4 1979 06 01 Released CE3J-DR741361-E Printed copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 1 of 5 HOSE,
2、REINFORCED RUBBER - FUEL LINE ESE-M2D286-A NOT TO BE USED FOR NEW DESIGN 1. SCOPE The material defined by this specification is a reinforced rubber hose with improved heat, fuel and ozone resistance. 2. APPLICATION The specification was released originally for material used for the fuel line, fuel t
3、ank filter hoses and related evaporative systems. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 CONSTRUCTION The hose shall consist of a smooth
4、-bore tube of butadiene/ acrylonitrile compound reinforced with one or more ply of a braided, knit, spiral or woven polyester fabric and covered with either a chlorosulfonated polyethylene or a chlorinated poly-ethylene compound. 3.2 BURST PRESSURE, min 250 psi (ASTM D 380) (1.8 MPa) 3.3 VACUUM COLL
5、APSE, max 10% Test Method: Subject the hose to a vacuum of 20 in Hg (68 kPa) while bent over a mandrel having a diameter 10 times the nominal O.D. of the hose. After and during the 24 h at 102 +/- 3 C, the outside diameter shall not be less than 92% of the original. 3.4 COLD FLEXIBILITY, Tube and Co
6、ver No cracks or breaks Test Method: An 18 in (450 mm) length of the hose filled with ASTM Fuel “C“ shall not crack or show other defects after being conditioned at -40 C for 70 h and bent 180 over a temperature conditioned mandrel 10 times the nominal O.D. of the hose. This flexing shall be accompl
7、ished with 4 s. 3.5 OZONE RATING, Cover 0 (FLTM BP 101-01) 3.6 HIGH TEMPERATURE RESISTANCE No cracks Test Method: A piece of hose bent into a free loop (approximately 10 in (250 mm) diameter) until ends meet shall be aged in an oven at 149 +/- 3 C for 70 h. At the end of the aging period the cover s
8、hall show no signs of cracking when examined under a 7 power glass. ENGINEERING MATERIAL SPECIFICATIONESE-M2D286-A Printed copies are uncontrolled Copyright 2009, Ford Global Technologies, LLC Page 2 of 5 3.7 OVALITY, min 75% Ovality will be expressed as a ratio of the inside minor to major diameter
9、 times 100. 3.8 PHYSICAL CHARACTERISTICS (ASTM D 380, taken from hose when applicable) 3.8.1 Original Properties Tube Cover Tensile Strength, psi 1200(8.3) 1300(9.0) (MPa), min Ultimate Elongation, 200 200 % min Modulus at 100%, 425 (2.9)-850 (5.9) 350 (2.4)-750 (5.2) psi (MPa) Hardness, IRHD 60 - 7
10、5 58 - 70 3.8.2 Heat Aged (ASTM D 573) (Tube-70 h at 125 +/- 2 C, Cover-168 h at 135 +/- 2 C) Tensile Strength -10 to +20 -15 to +30 Change, % Elongation Change, % -55 to +10 -60 to 0 Hardness Change 0 to +25 0 to +25 (Note: Hardness is not to exceed 90 durometer) 3.8.3 Immersion in ASTM Fuel “C“ (7
11、2 h at 22 +/- 2 C, then place in oven for 48 h at 70 +/- 2C, properties after dry out, except when noted) Tensile strength -10 to +25 0 to +50 change, % Elongation Change, % -10 to +15 -35 to +15 Hardness change, 0 to +18 0 to +25 (Note: Hardness is not to exceed 90 durometer) Volume change, % -18 t
12、o 0 -30 to 0 after dry out Volume change after 0 to +44 - fuel “C“, % 3.8.4 Fill 18 in (460 mm) hoses with fuel “C“. Stopper both ends. Test for 72 h at room temperature changing the fuel “C“ every 24 h. Remove fuel “C“ and place hoses in air circulating oven at 125 C for 72 h. Let hoses cool to roo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESEM2D286A2009HOSEREINFORCEDRUBBERFUELLINETOBEUSEDWITHFORDWSSM99P1111A 燃料 管用 增强 橡胶 软管 标准 FORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-745941.html