《FORD ESB-M1L85-C-2003 CABLE-LOW TENSION POLYETHYLENE INSULATED (EXTRA THIN WALL) - BARE TO BE USED WITH FORD WSS-M99P1111-A 《聚乙烯绝缘(超薄壁型)的裸露低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD ESB-M1L85-C-2003 CABLE-LOW TENSION POLYETHYLENE INSULATED (EXTRA THIN WALL) - BARE TO BE USED WITH FORD WSS-M99P1111-A 《聚乙烯绝缘(超薄壁型)的裸露低压电缆 与标准FORD WSS-M99P1111-A一起使用 》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2006 11 17 Revised ESB-M1L85-C/D re-activated back to N-Status; Revised 2, Table 1b, Table III and Table IV R. Lord2006 09 07 Revised ESB-M1L85-C/D inactivated and removed; no replacement named R. Lord 1967 07 24 Released AW1 # 1058 Printed co
2、pies are uncontrolled Copyright 2006, Ford Global Technologies, LLC Page 1 of 7 CABLE-LOW TENSION, POLYETHYLENE ESB-M1L85-A INSULATED - BARE CABLE-LOW TENSION, POLYETHYLENE ESB-M1L85-B INSULATED (THIN WALL) - BARE CABLE-LOW TENSION, POLYETHYLENE NOT TO BE USED FOR NEW DESIGN ESB-M1L85-C INSULATED (E
3、XTRA THIN WALL) - BARE CABLE, STRANDED (FLEXIBLE), LOW TENSION, NOT TO BE USED FOR NEW DESIGN ESB-M1L85-D POLYETHYLENE INSULATED (THIN WALL) BARE CABLE-LOW TENSION, POLYETHYLENE ESB-M1L86-A INSULATED - TINNED 1. SCOPE The materials defined by these specifications are stranded flame retardant cross-l
4、inked polyethylene or ethylene copolymer-covered low tension cables. The covering shall have a maximum service temperature of 150 C. 2. APPLICATION These specifications were released originally for cables used for automotive electrical harnesses. The ESB-M1L85-D specification was released for the tr
5、uck rear axle brake sensor jumper. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1 WIRE SIZE Shall be specified on engineering drawings and/or re
6、leased according to the SAE wire size numbers appearing in Table Ia. Example #16 gage ESB-M1L85-A. 3.2 COLOR The color of the flame retardant cross-linked polyethylene color shall be specified on the engineering drawing per the ES-D1AB-1274-AA Circuit description and Color Specification. The color s
7、hades shall be within the limits specified below (Reference Numbers per Color Association of the U.S., Inc.). ENGINEERING MATERIAL SPECIFICATIONESB-M1L85-A/B/C/D ESB-M1L86-A Printed copies are uncontrolled Copyright 2006, Ford Global Technologies, LLC Page 2 of 7 Color Nominal Dark Light Black None
8、None None Brown 70107 70108 70106 Tan 70093 70094 70092 Red 70180 70082 70179 Orange 70072 70041 70071 Yellow 70205 70068 70067 Dark Green 70065 70066 70064 Light Green 70062 70063 70061 Dark Blue 70086 70087 70085 Light Blue 70143 70144 70142 Purple 70135 70164 70134 Gray 70152 70153 70185 White 70
9、003 70004 None Pink 70098 70099 70097 3.3 CABLE QUALITY The materials shall meet all of the requirements listed herein and shall be equal to the original approved sample. 3.4 WIRE QUALITY The strands of the conductors prior to stranding shall consist of the following: ESB-M1L85 ESF-M2L1, soft or ann
10、ealed copper round bare wire. ESB-M1L86 ESF-M2L3, soft or annealed copper round tinned wire. 3.5 CABLE CONSTRUCTION See Tables Ia after the bend test, the cable shall be subjected to the dielectric test, para 3.6.3. ENGINEERING MATERIAL SPECIFICATIONESB-M1L85-A/B/C/D ESB-M1L86-A Printed copies are u
11、ncontrolled Copyright 2006, Ford Global Technologies, LLC Page 4 of 7 3.6.5 Cold Bend Test A straight specimen shall be reduced to a temperature of -40 C at a rate not to exceed 50 C/min. After maintaining this temperature for 3 h and while still at this low temperature, the cable shall be wrapped a
12、round the mandrel specified in Table II for 180 at the uniform rate of one turn in 10 s. The insulation shall be removed for a distance of 25 mm from each end of the specimen and the specimen subjected to the dielectric test, para 3.6.3. 3.6.6 Flame Test A bunsen burner having a 13 mm inlet, nominal
13、 bore of 19 mm, a length of approximately 102 mm, above the primary inlets, equipped with a wing-top flame spreader having a 1.6 x 51 mm opening fitted to the top of the burner shall be used. A 610 mm sample shall be suspended taut in a horizontal position within a partial enclosure which allows a f
14、low of sufficient air for complete combustion but is free from drafts. The tip of a 51 mm gas flame with an inner cone one-third its height shall than be applied to the center of the suspended cable. The time of application of the flame shall be 15 s for SAE wire sizes 10 through 20, and 30 s for SA
15、E wire size 8. After removal of the bunsen burner flame, the specimen shall not continue to burn for more than 30 s. 3.6.7 Abrasion Resistance As per Table III (SAE J1128) 3.6.8 Electrical Overload Test In an ambient temperature of 24 +/- 3 C a 1524 mm sample cable suspended in air, or lying on a tr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESBM1L85C2003CABLELOWTENSIONPOLYETHYLENEINSULATEDEXTRATHINWALLBARETOBEUSEDWITHFORDWSSM99P1111A 聚乙烯

链接地址:http://www.mydoc123.com/p-745199.html