《ENV 14226-2002 en Advanced Technical Ceramics - Test Methods for Ceramic Powders - Determination of Calcium Magnesium Iron and Aluminium in Silicon Nitride by Using Flame Atomic Ab.pdf》由会员分享,可在线阅读,更多相关《ENV 14226-2002 en Advanced Technical Ceramics - Test Methods for Ceramic Powders - Determination of Calcium Magnesium Iron and Aluminium in Silicon Nitride by Using Flame Atomic Ab.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、DRAFT FOR DEVELOPMENT Advanced technical ceramics lest methods for ceramic powders Determination of calcium, magnesium, o 4 4 o o o iron and aluminium in silicon nitride by using flame atomic absorption spectroscopy (FAAS) or inductively coupled plasma atomic emission spectroscopy (ICP-AES) ICs 81.0
2、60.30 DD ENV 14226:2002 Iron 5 x to 250 x (w/w); Magnesium 5 x to 200 x (w/w); Aluminium 5 x to 1000 x (wh). 4 Principle The test sample is decomposed using either acid pressure digestion, or acid pressure microwave digestion. The resulting solution is diluted to a defined volume and nebulization in
3、to a flame for FAAS, or into a plasma, for ICP-AES (see clause i). For each element, comparison is made of the recorded absorbance or emitted intensity for a determined analytical peak with those of a range of solutions of known concentrations. 5 Sampling Bulk sampling is not within the scope of thi
4、s European Prestandard and the method starts with a laboratory sized sample. 3 ENV 14226:2002 (E) 6 Reagents and materials 6.1 General All reagents, and substances, shall be of at least analytical grade. Distilled or de-ionised water, conforming to IS0 3696, shall be used throughout the whole proced
5、ure. 6.2 Reagents for preparation 6.2.1 Hydrofluoric acid HF p20 about 1,16 g ml- 6.2.2 Nitric acid “03 p20 about 1,4 g ml-I 6.3.Reagents for calibration 6.3.1 All reagents shall be of ultra high purity. 6.3.2 Silicon, commercial solution with very low and known impurity levels, concentration 1 O gl
6、-I 6.3.3 Calcium, commercial solution or solution obtained by the dissolution of a pure chemical product, concentration O, i g1-l. 6.3.4 Magnesium, commercial solution or solution obtained by the dissolution of a pure chemical product, concentration O, 1 gl-. 6.3.5 Iron, commercial solution or solut
7、ion obtained by the dissolution of a pure chemical product, concentration O, i g1-l. 6.3.6 Aluminium, commercial solution or solution obtained by the dissolution of a pure chemical product, concentration O, 1 gl-. 7 Apparatus 7.1 Spectrometer used for FAAS and ICP-AES analysis should comply with the
8、 requirements laid down in ECSCK 9. The ICP-AES shall be equipped with a nebulization system and torch resistant to hydrofluoric acid. 7.2 Drying oven, capable of being controlled at (1 10 f 10) OC. 7.3 Desiccator containing effective desiccant. 7.4 Balance, to read to 0,l mg. 7.5 Sample jar or bag,
9、 with a seal. 4 ENV 14226:2002 (E) 7.6 50 ml volumetric flasks, resistant to hydrofluoric acid (e.g. polypropylene, PTFE). 7.7 Vessels, resistant to hydrofluoric acid, of at least 30 ml capacity, and suitable for operation at (170 f 15) “C for 15 h, for use with (7.8). 7.8 Acid pressure digestion ap
10、paratus. 7.9 Vessels, resistant to hydrofluoric acid, for use with (7.10). 7.1 O Microwave digestion system. 8 Sample preparation Dry approximately log of the sample at (1 10 f 10) OC, in the drying oven (7.2) for at least 1 h. Remove and cool it to room temperature in a desiccator (7.3). When cool
11、store the sample in a jar or bag that is airtight (7.5). 9 Procedure 9.1 General 9.1.1 Dissolve the test sample by acid pressure digestion (9.2) or by acid pressure microwave digestion (9.3) 9.1.2 Run a blank in parallel with the chosen procedure, using identical reagents, conditions, and dilutions
12、throughout. 9.2 Acid pressure digestion Weigh (0,100 f 0,000 5) g of test sample (8) into the PTFE-lined vessel (7.6). Carefully add 3 ml of HF (6.2.1) and 1 ml of “03 (6.2.2). Install the cap and close the pressure vessel according to the manufacturers instructions. Place the pressure vessel into t
13、he heating block and digest for 15 h at (170 f 15) “C. Allow to cool. After cooling, open the pressure vessel according to the manufacturers instructions. Check that the test portion has been completely digested. If not, repeat the digestion. 5 ENV 14226:2002 (E) Transfer the dissolved sample to a 5
14、0 ml volumetric flask (7.6) and rinse the pressure vessel, and lid with distilled or de-ionised water. Make up to the mark with distilled or de-ionised water and mix well. 9.3 Acid pressure microwave digestion Examples of procedures: 9.3.1 Weigh 0,lg f 0,000 5 g of test sample (8) into the vessel (7
15、.9). Add 5ml of HF (6.2.1) and 1 ml of “03 (6.2.2) and seal according to the manufacturers instructions. Put the capped vessel into the microwave. Apply the following stages: - Stage 1 : Power level 60% for 2 min; Stage 2: Power level 30% for 15 min; Stage 3: Power level 0% for 5 min; Stage 4: Power
16、 level 20% for 20 min. - - - Allow the vessel to cool in the microwave for about 20 min. Repeat the heating cycle once more. Inspect to see if the test sample has completely digested. When cool, open the vessel according to the manufacturers instructions. Transfer the dissolved sample into a 50 ml p
17、olypropylene volumetric flask (7.6), and rinse the pressure vessel, and lid with distilled or de-ionised water. Mix, and make up to the mark with distilled or de-ionised water. 9.3.2 Weigh 0,l g f 0,000 5 g of test sample (8) into the pressure vessel (7.7) Add, carefully, 10 ml of HF (6.2.1) and 2 m
18、l of “03 (6.2.2), and seal the vessel according to the manufacturers instructions. Place the capped vessel into the microwave. Apply the following stages: 6 ENV 14226:2002 (E) - Stage 1: Temperature 50C for 2 min; Stage 2: Temperature 150C for 6 min; Stage 3: Temperature 260C for 18 min; Stage 4: Te
19、mperature 0C for 10 min. - - - Cool and open the vessel according to the manufacturers instructions. Inspect the solution. If the sample has not completely dissolved repeat stages 1 to 4 again. Transfer the solution into a 50 ml volumetric flask (7.6), washing the pressure vessel and lid with distil
20、led or de-ionised water. Mix and make up to the mark with distilled or de-ionised water. 10 Calibration solutions A calibration graph is obtained using calibration solutions prepared to span the range of concentrations of elements to be determined in the test solution. The calibration solutions are
21、prepared using the same acids that were used to digest the test sample to ensure accurate matrix matching. The following procedure is given as an example: Prepare the calibration solutions by adding the volumes of solutions indicated in Table 1 to a series of 50 ml volumetric flasks (7.6). When addi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENV142262002ENADVANCEDTECHNICALCERAMICSTESTMETHODSFORCERAMICPOWDERSDETERMINATIONOFCALCIUMMAGNESIUMIRONANDALUMINIUMINSILICONNITRIDEBYUSINGFLAMEATOMICABPDF

链接地址:http://www.mydoc123.com/p-727355.html