EN 61537-2007 en Cable management - Cable tray systems and cable ladder systems《电缆管理 电缆托盘系统和电缆梯架系统》.pdf
《EN 61537-2007 en Cable management - Cable tray systems and cable ladder systems《电缆管理 电缆托盘系统和电缆梯架系统》.pdf》由会员分享,可在线阅读,更多相关《EN 61537-2007 en Cable management - Cable tray systems and cable ladder systems《电缆管理 电缆托盘系统和电缆梯架系统》.pdf(86页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 61537:2007Cable management Cable tray systems and cable ladder systemsThe European Standard EN 61537:2007 has the status of a British StandardICS 29.120.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54
2、g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61537:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2007 BSI 2007ISBN 978 0 580 50168 5National forewordThis British Standard was published b
3、y BSI. It is the UK implementation of EN 61537:2007. It is identical with IEC 61537:2006. It supersedes BS EN 61537:2002, which will be withdrawn on 1 December 2009.The UK participation in its preparation was entrusted to Technical Committee PEL/213, Cable management.A list of organizations represen
4、ted on PEL/213 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued sin
5、ce publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61537 NORME EUROPENNE EUROPISCHE NORM January 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Sta
6、ssart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61537:2007 E ICS 29.120.10 Supersedes EN 61537:2001English version Cable management - Cable tray systems and cable ladder systems (IEC 61537:2006) Sy
7、stmes de cblage - Systmes de chemin de cbles et systmes dchelle cbles (CEI 61537:2006) Fhrungssysteme fr Kabel und Leitungen - Kabeltrgersysteme fr elektrische Installationen (IEC 61537:2006) This European Standard was approved by CENELEC on 2006-12-01. CENELEC members are bound to comply with the C
8、EN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or t
9、o any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official
10、 versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slo
11、vakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61537:2007 2 Foreword The text of document 23A/513/FDIS, future edition 2 of IEC 61537, prepared by SC 23A, Cable management systems, of IEC TC 23, Electrical accessories, was submitted to the IEC-CENELEC parallel vote and was ap
12、proved by CENELEC as EN 61537 on 2006-12-01. This European Standard supersedes EN 61537:2001. It incorporates additional tables, annexes and figures as well as revisions to such that appeared in EN 61537:2001. In places, the text has been substantially altered including: the classification system, t
13、ests for resistance against corrosion, re-written SWL test procedure, re-written section on electrical non-conductivity. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-0
14、9-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-12-01 Annexes ZA and ZB have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61537:2006 was approved by CENELEC as a European Standard without any modificat
15、ion. _ 3 EN 61537:2007 CONTENTS 1 Scope . H6 2 Normative references H6 3 Terms and definitions H7 4 General requirements H9 5 General conditions for tests. H10 6 Classification. H11 7 Marking and documentation. H14 8 Dimensions . H15 9 Construction H16 10 Mechanical properties . H17 11 Electrical pr
16、operties. H29 12 Thermal properties H31 13 Fire hazards H31 14 External influences H33 15 Electromagnetic compatibility (EMC) H35 Annex A (informative) Sketches of typical cable tray lengths and cable ladder lengths. H53 Annex B (informative) Sketches of typical support devices H54 Annex C (informat
17、ive) Protective earth (PE) function. H56 Annex D (normative) Methods of applying and distributing a UDL for SWL tests using load distribution plates. H57 Annex E (informative) Typical methods of applying a UDL for SWL tests . H65 Annex F (informative) Example for the determination of TDF . H67 Annex
18、 G (informative) Example for clarification of allowed creep . H69 Annex H (informative) Information for a safe installation of pendants with cantilever brackets H70 Annex I (informative) Summary of compliance checks . H72 Annex J (normative) Compliance checks to be carried out for cable tray systems
19、 and cable ladder systems already complying with IEC 61537:2001 H74 Annex K (informative) Environmental categories and corrosion rates for zinc only galvanising H76 Annex L (informative) Illustrative flow chart for the SWL tests H77 Annex ZA (normative) Normative references to international publicat
20、ions with their corresponding European publications .81 Annex ZB (informative) A-deviations .82 Bibliography .80 EN 61537:2007 4 HFigure 1 Safe working load test General arrangement H36 HFigure 2 Safe working load test types I, II and III (see 10.3.1 to 10.3.3). H38 HFigure 3 Safe working load test
21、IV (see 10.3.4) . H39 HFigure 4 Safe working load for single span test (see 10.4). H39 HFigure 5 Safe working load test for fittings H42 HFigure 6 Test set-up for cantilever brackets H45 HFigure 7 Test set-up for pendants . H46 HFigure 8 Impact test stroke arrangement. H47 HFigure 9 Test set-up for
22、electrical continuity H48 HFigure 10 Arrangement for the flame test H49 HFigure 11 Enclosure for the flame test H50 HFigure 12 Load and temperature diagrams with respect to time for test 10.2.1.3 H51 HFigure 13 Typical arrangement of surface resistivity test . H52 HFigure A.1 Solid bottom cable tray
23、 lengths H53 HFigure A.2 Perforated cable tray lengths . H53 HFigure A.3 Mesh cable tray lengths. H53 HFigure A.4 Cable ladder lengths H53 HFigure B.1 Cantilever brackets H54 HFigure B.2 Pendants. H55 HFigure B.3 Fixing brackets H55 HFigure D.1 Examples of distribution load points across the width.
24、H57 HFigure D.2 Typical arrangement of load distribution plates H58 HFigure D.3 Example of equispaced point loads along the length H59 HFigure D.4 Examples of test load distribution on cable ladder lengths H60 HFigure D.5 n rungs H61 HFigure D. 6 Example of loading on three rungs H62 HFigure D.7 Two
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN615372007ENCABLEMANAGEMENTCABLETRAYSYSTEMSANDCABLELADDERSYSTEMS 电缆 管理 托盘 系统 梯架 PDF

链接地址:http://www.mydoc123.com/p-720268.html